Richard  Ordonez

Richard Ordonez

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RORichard Ordonez
Richard Ordonez
CHCody K. Hayashi
Cody K. Hayashi
CTCarlos M. Torres
Carlos M. Torres
JMJordan L. Melcher
Jordan L. Melcher
NKNackieb Kamin
Nackieb Kamin
DGDavid Garmire
David Garmire
Historically, graphene-based transistor fabrication has been time-consuming due to the high demand for carefully controlled Raman spectroscopy, physical vapor deposition, and lift-off processes. For the first time in a three-terminal graphene field-effect transistor embodiment, we introduce a rapid fabrication technique that implements non-toxic eutectic liquid-metal Galinstan interconnects and an electrolytic gate dielectric comprised of honey. The goal is to minimize cost and turnaround time between fabrication runs; thereby, allowing researchers to focus on the characterization of graphene phenomena that drives innovation rather than a lengthy device fabrication process that hinders it. We demonstrate characteristic Dirac peaks for a single-gate graphene field-effect transistor embodiment that exhibits hole and electron mobilities of 213 ± 15 and 166 ± 5 cm2/V·s respectively. We discuss how our methods can be used for the rapid determination of graphene quality and can complement Raman Spectroscopy techniques. Lastly, we explore a PN junction embodiment which further validates that our fabrication techniques can rapidly adapt to alternative device architectures and greatly broaden the research applicability.

14 January 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
JMJordan Melcher
Jordan Melcher
KEKareem Elassy
Kareem Elassy
RORichard Ordonez
Richard Ordonez
CHCody Hayashi
Cody Hayashi
Aaron OhtaAaron Ohta
Aaron Ohta
DGDavid G. Garmire
David G. Garmire
Advancements in flexible circuit interconnects are critical for widespread adoption of flexible electronics. Non-toxic liquid-metals offer a viable solution for flexible electrodes due to deformability and low bulk resistivity. However, fabrication processes utilizing liquid-metals suffer from high complexity, low throughput, and significant production cost. Our team utilized an inexpensive spray-on stencil technique to deposit liquid-metal Galinstan electrodes in top-gated graphene field-effect transistors (GFETs). The electrode stencils were patterned using an automated vinyl cutter and positioned directly onto chemical vapor deposition (CVD) graphene transferred to polyethylene terephthalate (PET) substrates. Our spray-on method exhibited a throughput of 28 transistors in under five minutes on the same graphene sample, with a 96% yield for all devices down to a channel length of 50 μm. The fabricated transistors possess hole and electron mobilities of 663.5 cm2/(V·s) and 689.9 cm2/(V·s), respectively, and support a simple and effective method of developing high-yield flexible electronics.

24 August 2016 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
RORichard Ordonez
Richard Ordonez
CHCody K. Hayashi
Cody K. Hayashi
CTCarlos M. Torres
Carlos M. Torres
NHNoah Hafner
Noah Hafner
JAJames R. Adleman
James R. Adleman
DGDavid Garmire
David Garmire
A novel integration technique is demonstrated that combines 2-D graphene with galinstan (eutectic gallium-based alloy) into flexible, compact, and durable devices. This unique combination enables the next-generation electronic devices with miniaturized microfluidic capabilities. Robust performance is exhibited across a wide range of flexure with less than 5.5% resistance change when subjected to repeated deformations as small as a 4-mm radius of curvature. To fully integrate both graphene and liquid metal in a microfluidics platform, robust interconnects are realized for a variety of flexible electronics applications.

23 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
KKKevin Kam
Kevin Kam
BTBrianne Tengan
Brianne Tengan
CHCody Hayashi
Cody Hayashi
RORichard Ordonez
Richard Ordonez
DGDavid Garmire
David Garmire
We have pioneered the use of liquid polar organic molecules as alternatives to rigid gate-dielectrics for the fabrication of graphene field-effect transistors. The unique high net dipole moment of various polar organic molecules allows for easy manipulation of graphene’s conductivity due to the formation of an electrical double layer with a high-capacitance at the liquid and graphene interface. Here, we compare the performances of dimethyl sulfoxide (DMSO), acetonitrile, propionamide, and valeramide as polar organic liquid dielectrics in graphene field-effect transistors (GFETs). We demonstrate improved performance for a GFET with a liquid dielectric comprised of DMSO with high electron and hole mobilities of 154.0 cm2/Vs and 154.6 cm2/Vs, respectively, and a Dirac voltage <5 V.

28 January 2025 in Electronics
Verified
Journal Article
Open access
PDF file
AGAnthony Gasbarro
Anthony Gasbarro
YMYong-Sung Masuda
Yong-Sung Masuda
RORichard Ordonez
Richard Ordonez
JWJeffrey A. Weldon
Jeffrey A. Weldon
VLVictor Manuel Lubecke
Victor Manuel Lubecke
Mechanical exfoliation of two-dimensional (2D) materials using adhesive tape is a widely used method for producing high-quality single-layer graphene flakes. However, this technique is time-consuming, with low yields and inconsistent results due to process variations and human error. This paper introduces a modular system designed to rigorously test and optimize the conditions for 2D material deposition, with a focus on graphene. The system is adaptable to a range of inexpensive, commercially available linear stages and stepper motors, providing precise, independent control over key parameters such as peel speed and angle—both of which are critical in deposition yields. Tests confirmed the system’s accuracy within ±0.7% relative speed error across a range of speeds (1 μm/s to 5000 μm/s) and peel angle control from 0∘ to 120∘. Additionally, the system automates control of the key factors at the most demanding step of the exfoliation process while being affordable and easily assembled, making it accessible for laboratories and educational institutions to explore the optimal conditions for scaling 2D material production. This system offers the capability to gain critical insights into the exfoliation process, driving improved yields and scalability, which are essential for fabricating highly specialized devices that rely on 2D materials.

25 September 2023
Verified
Conference Paper
Closed access
LHLewis Hsu
Lewis Hsu
RORichard Ordonez
Richard Ordonez
CHCody Hayashi
Cody Hayashi
MMMario Malfavon
Mario Malfavon
CBChanning Bolt
Channing Bolt
RGRobert George
Robert George
Utilization of oily wastewater collection systems at shore facilities are required for Navy vessels when moored piers ide or returning to homeport. While in state and federal waters (less than 12 nautical miles from shore), collected oily wastewater is often processed through specialized shore systems (i.e., the bilge and oily wastewater treatment system) to separate oil and grease fractions from the bulk wastewater originating from vessels. In certain situations, chemical contaminants such as metals or organics may be found within discharged oily wastewater. While these constituents are generally easily treated in industrial wastewater facilities, emerging and ubiquitous contaminants such as perfluorooctane sulfonic acid (PFOS) and other per-and polyfluoroalkyl substances (PFAS) are not easily treated with conventional wastewater facilities and may require additional treatment. The work presented here describes the initial assessment of electrocoagulation as a rapid treatment of ship-generated oily wastewater. We show that aluminum-based electrocoagulation can effectively remove oil-grease fractions from samples of saline water at relatively low voltages. In these experiments, applied DC voltages ranged between 2V and 4V and measured electrical currents ranged between 2A and 13A. We present treatment efficiencies of approximately 80% with electrocoagulation times of less than 15 minutes. Tests of PFOS removal show that at least 75% of PFOS from the water fraction can be removed through a 10-minute treatment cycle, with the maj ority ending up in the foam fraction. These results show that electrocoagulation is a promising approach for oily wastewater treatment at shore facilities supporting maritime vessels. Moreover, the low voltages and currents observed can lend themselves to the development of portable devices for effective treatment at low power demands. When utilized as a pre-treatment process, electrocoagulation can significantly remove a large fraction of contaminants. Removal or reduction of the oily wastewater waste stream also has the potential to reduce or elinate the introduction of seawater to conventional wastewater treatment plants. Thus, when combined with targeted downstream treatment processes, electrocoagulation can be an inexpensive, yet effective, part of a wastewater treatment process.