Tan Qiulin

Dr. Tan Qiulin


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2014 in Sensors
Verified
Journal Article
Open access
PDF file
QTQiulin Tan
Qiulin Tan
TLTao Luo
Tao Luo
XJXiong Jijun
Xiong Jijun
TQTan Qiulin
Tan Qiulin
XJXiaxia Ji
Xiaxia Ji
WZWendong Zhang
Wendong Zhang
To meet measurement needs in harsh environments, such as high temperature and rotating applications, a wireless passive Low Temperature Co-fired Ceramics (LTCC) temperature sensor based on ferroelectric dielectric material is presented in this paper. As a LC circuit which consists of electrically connected temperature sensitive capacitor and invariable planar spiral inductor, the sensor has its resonant frequency shift with the variation in temperature. Within near-filed coupling distance, the variation in resonant frequency of the sensor can be detected contactlessly by extracting the impedance parameters of an external antenna. Ferroelectric ceramic, which has temperature sensitive permittivity, is used as the dielectric. The fabrication process of the sensor, which differs from conventional LTCC technology, is described in detail. The sensor is tested three times from room temperature to 700 °C, and considerable repeatability and sensitivity are shown, thus the feasibility of high performance wireless passive temperature sensor realized by LTCC technology is demonstrated.

2 August 2013 in Sensors
Verified
Journal Article
Open access
PDF file
QTQiulin Tan
Qiulin Tan
TQTan Qiulin
Tan Qiulin
TQTan Qiulin
Tan Qiulin
LQLi Qin
Li Qin
WZWendong Zhang
Wendong Zhang
MYMingliang Yang
Mingliang Yang
A wireless passive high-temperature pressure sensor without evacuation channel fabricated in high-temperature co-fired ceramics (HTCC) technology is proposed. The properties of the HTCC material ensure the sensor can be applied in harsh environments. The sensor without evacuation channel can be completely gastight. The wireless data is obtained with a reader antenna by mutual inductance coupling. Experimental systems are designed to obtain the frequency-pressure characteristic, frequency-temperature characteristic and coupling distance. Experimental results show that the sensor can be coupled with an antenna at 600 °C and max distance of 2.8 cm at room temperature. The senor sensitivity is about 860 Hz/bar and hysteresis error and repeatability error are quite low.