Amit Davidson

Dr. Amit Davidson

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2022 in International Orthopaedics
Verified
Journal Article
Open access
PDF file
ADAmit Davidson
Amit Davidson
SBShlomo Blum
Shlomo Blum
EHElad Harats
Elad Harats
EKErick Kachko
Erick Kachko
AEAhmad Essa
Ahmad Essa
PGPeter V. Giannoudis
Peter V. Giannoudis
Introduction: The recently developed femoral neck system (FNS) for treatment of femoral neck fractures (FNF), comprises theoretical biomechanical advantages compared to other implants. The aim of this study was to validate the safety and to report outcomes of patients treated with the FNS. Method: A retrospective multicentric analysis of patients treated by FNS with a minimum of three months of follow-up. Details analysed from three medical centres were operative duration, estimated blood loss, initial hospitalisation duration, fixation quality as well as complications and reoperation rate. Patients who had revision surgery were compared to all other patients to identify risk factors for failure. In addition, a literature review was performed to analyse data on FNS clinical implementation and patient’s outcomes. The two data sets were combined and analysed. Results: One-hundred and two patients were included in this study cohort with an average follow-up of seven months (range 3–27). Ten papers were included in the literature review, reporting data on 278 patients. Overall, 380 patients were analysed. Average age was 62.6 years, 52% of the fractures were classified as Gardens 1–2. Overall, the revision rate was 9.2% (14 patients diagnosed with cut-out of implant, 10 with AVN, 8 with non-union and 8 with hardware removal). For the 102 patients in the cohort risk factors for reoperation included patients age, surgeon seniority and inadequate placement of the implant. Conclusion: This study shows that FNS is a safe treatment option for FNF. Intra-operative parameters and failure rates are comparable to previously reported rates for this implant and other frequently used implants.

1 April 2023 in Journal of Orthopaedic Trauma
Verified
Journal Article
Closed access
ADAmit Davidson
Amit Davidson
YRYuval Revach
Yuval Revach
PRPaul Mbbs Rodham
Paul Mbbs Rodham
RMRami Mosheiff
Rami Mosheiff
LKLeonid Kandel
Leonid Kandel
YWYoram Alexander Weil
Yoram Alexander Weil
Objective: To evaluate the intraobserver and interobserver reliability of the 2018 OTA/AO trochanteric hip fracture (THF) classification compared with the 1983 OTA/AO Muller classification system. To further delineate the reliability of classifying stable and unstable THF using the 2 classification systems. Design: Radiographic observational study. Setting: Multicenter, one Level 1 and one Level 2 trauma centers. Participants/Patients: Seventy-three radiographic series of patients treated operatively for THF were evaluated by 6 orthopaedic surgeons. Intervention: The OTA/AO THF classification system was applied by each surgeon to 73 cases in 2 independent assessments performed 4 weeks apart: once by the old classification followed by the new 2018 OTA/AO classification. Each radiographic series included lateral hip and anteroposterior initial radiographs. Eight random cases were duplicated in each of the surveys to evaluate the intraobserver reliability. Main Outcome Measurements: Intraobserver and interobserver of the group, subgroup and fracture stability classification determined by the interclass coefficient (ICC) and Cohen kappa values. Results: The interobserver reliability for the group classification (31A1/A2/A3) was moderate using the new classification, whereas substantial agreement was shown using the old classification (0.49 and 0.69, respectively). The reliability of the fracture stability classification was higher using the old classification (0.70 vs. 0.52). Subgroup classifications interobserver agreement was fair for both classification systems, although lower reliability was shown in the old classification (0.34 vs. 0.31). Conclusions: The new OTA/AO classification has a lower interobserver reliability for THF classification when compared with the old one.

1 March 2022 in Injury
Verified
Journal Article
Closed access
ADAmit Davidson
Amit Davidson
SHSaadit S. Houri
Saadit S. Houri
JCJoshua Cohen
Joshua Cohen
GFGuy Feldman
Guy Feldman
RMRami Mosheiff
Rami Mosheiff
YWYoram A. Weil
Yoram A. Weil

1 October 2023 in Journal of Orthopaedic Trauma
Verified
Journal Article
Closed access
ADAmit Davidson
Amit Davidson
Peter V GiannoudisPeter V Giannoudis
Peter V Giannoudis
Objective: The objective of this study was to compare clinical outcomes of patients with trochanteric hip fractures treated with specific different cephalomedullary nail (CMN) designs. Methods: A scoping review of the English literature was performed. Inclusion criteria were studies comparing perioperative and postoperative outcomes of trochanteric hip fractures fixated by CMNs for one of the following CMN designs: short versus long nails, blade versus screw fixation, dual versus single lag screw fixation, and application of cement augmentation. Inclusion criteria consisted of human comparative clinical trials (randomized and observational). Exclusion criteria included noncomparative studies, studies comparing CMN with non-CMN devices or with arthroplasty, studies with less than 3 months follow-up, studies that did not provide relevant clinical outcome measures, biomechanical, finite element analyses, animal, or in vitro publications. Data regarding reoperations, peri-implant fractures, mechanical failure, nonunion, infection rates, and functional outcomes were reviewed. Results: Twenty-two studies met the inclusion criteria and formed the basis of this study. Failure of fixation rates and reoperation rates for each of the nail designs selected for evaluation is presented, in addition to specific outcome measures relevant to that nail design which was explored: peri-implant fracture—short versus long nails, and specific mechanism of failure—blade versus plate. Conclusions: Decreased failure of fixation and reoperations rates were found for integrated dual lag screw fixation. Similar fixation failure and reoperation rates were found for the long versus short nails and for blade versus screw fixation. Level of Evidence: Diagnostic, Level IV.

15 September 2023 in International Orthopaedics
Verified
Journal Article
Open access
PDF file
ADAmit Davidson
Amit Davidson
VGVasileios P. Giannoudis
Vasileios P. Giannoudis
GKGeorgios Kotsarinis
Georgios Kotsarinis
ESEmmanuele Santolini
Emmanuele Santolini
CTConstantinos Tingerides
Constantinos Tingerides
PGPeter V. Giannoudis
Peter V. Giannoudis
Purpose: Obstetric outcomes in women following pelvic injuries requiring surgical fixation is not thoroughly known. We aimed to evaluate if radiographic measurements (RMs) can be used to provide information on delivery methods outcome after these injuries, and to evaluate if metal work removal is required prior to delivery. Method: A retrospective study in a level 1 trauma centre of female patients with pelvic fractures treated operatively, aged 16–45 at the time of injury. Participants completed a questionnaire regarding their obstetric history. RM evaluating pelvic symmetry, displacement, and pelvimetry were conducted on postoperative radiographs and CT scans. Patients who gave birth after the injury were divided to two groups according to the delivery method: vaginal delivery (VD) and caesarean section (CS). These two groups RM were compared. Results: Forty-four patients were included, comparison of the RM of patients who delivered by CS (9) and patients who had only VD (11) showed no significant difference between the groups. Two patients underwent a trial of VD who subsequently underwent urgent CS due to prolonged labour, their RM were below the average and their pelvimetry measurements were above the cut-off for CS recommendation. Eleven patients had uncomplicated VD, all had retained sacroiliac screws at the time of delivery and one patient had an anterior pubic plate. Conclusion: Postoperative RM did not show an effect on delivery method of women after pelvic fracture fixation. A relatively high number of patients who underwent normal vaginal delivery had retained sacroiliac screws. These findings can form the foundation for larger cohort studies.

2 August 2023 in Endocrine Practice
Verified
Journal Article
Closed access
GZGershon Zinger
Gershon Zinger
ADAmit Davidson
Amit Davidson
NSNoa Sylvetsky
Noa Sylvetsky
YLYedin Levy
Yedin Levy
APAmos Peyser
Amos Peyser