Viktória Barna

Mrs. Viktória Barna


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
VBViktória Barna
Viktória Barna
DRDaniela Ridzoňová
Daniela Ridzoňová
Andrea MajlingovaAndrea Majlingova
Andrea Majlingova
Climate change is intensifying natural hazards across Central Europe, increasing pressure on national systems of climate change adaptation (CCA), disaster risk reduction (DRR), and civil protection. Although international and European policy frameworks promote coherence among these domains, their practical integration remains uneven. This study presents a comparative governance analysis of five Central European countries (Slovakia, Czechia, Hungary, Poland, and Austria), examining how CCA, DRR, and civil protection are integrated across strategic, institutional, operational, and financial dimensions. A structured qualitative assessment of national strategies, legal acts, and institutional arrangements was conducted using a standardized indicator-based framework. The results reveal systematic cross-dimensional asymmetries. Strategic alignment between CCA and DRR is relatively advanced across all countries, largely driven by international and EU policy frameworks. However, institutional coordination mechanisms, operational integration of climate risk information into preparedness planning, and dedicated financing for prevention and adaptation remain weak or fragmented in most cases. Civil protection systems continue to be predominantly response-oriented, with limited linkage to long-term climate risk governance. Based on these patterns, the study identifies distinct national integration typologies and highlights key governance gaps constraining sustainable climate risk management. The findings underline that effective integration depends not only on strategic commitments but on reinforcing linkages across institutions, operational practice, and financing. The study concludes by identifying concrete governance adjustments needed to strengthen cross-sectoral coordination, climate-informed preparedness, and stable financing mechanisms for resilience-building in Central Europe.

12 June 2026 in Fire
Verified
Journal Article
Open access
PDF file
LTLudmila Terenova
Ludmila Terenova
Andrea MajlingovaAndrea Majlingova
Andrea Majlingova
EMEva Mračková
Eva Mračková
IMIveta Mitterová
Iveta Mitterová
VBViktória Barna
Viktória Barna
Cross-laminated timber (CLT) is increasingly used in multi-story timber construction, but its combustible nature requires reliable fire protection, particularly in layered wall assemblies with concealed cavities. This study compares two medium-scale cross-laminated timber (CLT) sandwich wall assemblies exposed to radiant heat flux of 20 kW/m2 for 90 min: an uncoated reference assembly and an assembly with PROMADUR® intumescent coating applied to the CLT surfaces. Both specimens consisted of a 90 mm three-ply CLT panel encapsulated with 12.5 mm gypsum-fiber boards fixed to a wooden stud frame forming a 40 mm installation cavity. Fire-test observations were supplemented by simultaneous thermal analysis (STA), i.e., thermogravimetry (TG)/differential thermogravimetry (DTG)/differential scanning calorimetry (DSC), of uncoated and coated CLT specimens under oxidative conditions. During the applied medium-scale radiant exposure, the unexposed-face temperatures of both assemblies remained below the insulation temperature-rise limits defined in STN EN 1363-1; however, these limits were used only as a comparative benchmark and the test does not represent a formal fire-resistance classification. The coated assembly showed improved thermal protection during the early and intermediate stages of exposure, delaying a critical thermal event near the wooden stud by approximately 35 min. However, flaming combustion of the stud occurred at about 75 min and led to degradation of the intumescent char within the cavity. In contrast, the uncoated assembly reached higher early CLT surface temperatures but showed no flaming combustion during the test. STA results supported the fire-test interpretation: the coated specimen showed a 37% reduction in peak DTG rate, a higher residual mass at the end of the test, and substantially greater mass loss in the 150–280 °C range, consistent with intumescent activation and volatile release. The results indicate that, under the tested medium-scale exposure, the intumescent coating improved early and intermediate thermal protection of the CLT surface, but did not prevent late-stage cavity flaming involving the wooden stud. Therefore, the behavior of intumescent-coated CLT in partially enclosed cavities with combustible framing should be validated under replicated, standardized and larger-scale fire exposure.

2 September 2026 in Fire
Verified
Journal Article
Open access
PDF file
Andrea MajlingovaAndrea Majlingova
Andrea Majlingova
LTLudmila Terenova
Ludmila Terenova
VBViktória Barna
Viktória Barna
IMIveta Mitterova
Iveta Mitterova
Eva MračkováEva Mračková
Eva Mračková
The fire response of cross-laminated timber (CLT) sandwich wall assemblies depends on interactions among the structural core, lining, cavities and secondary timber members. This study examines the thermal roles of these layers under medium-scale radiant exposure. The thermogravimetric mass change, mass-loss rate and heat-flow response were obtained for CLT, Fermacell® gypsum–fiber board and timber stud specimens by simultaneous thermal analysis. One complete, artifact-free record per material group was selected for mechanistic comparison; the data were not used to characterize material variability statistically. The degradation intervals were compared qualitatively with temperatures, visual observations and post-test damage recorded during a 90 min exposure of the wall assembly at 20 kW/m2. Fermacell® retained 77.8% of its initial mass; CLT and stud specimens retained 22.5% and 20.8%, respectively. The largest mass loss of both wood-based materials occurred at 280–430 °C, with mass-loss-rate peaks at 372.1 °C for the CLT and 359.4 °C for the stud. The lining initially delayed heat transfer. After board cracking, cavity heating was followed by the degradation and glowing of the timber stud. Layer-specific thermal analysis supports the mechanistic interpretation of the tested assembly, but it neither predicts event timing nor replaces standardized fire resistance testing or classification.

3 November 2026 in Fire
Verified
Journal Article
Open access
PDF file
Andrea MajlingovaAndrea Majlingova
Andrea Majlingova
VBViktória Barna
Viktória Barna
QXQiang Xu
Qiang Xu
Wood exposed to fire undergoes both oxygen-independent thermal degradation and oxidative reactions, making the direct transfer of kinetic parameters obtained under inert conditions to fire applications potentially uncertain. This study investigated the effects of atmosphere and heating rate on the thermal degradation and apparent kinetics of Norway spruce (Picea abies (L.) H. Karst.). Simultaneous thermogravimetry and differential scanning calorimetry were performed under nitrogen and synthetic air at heating rates of 10, 25, and 50 °C min−1. Under nitrogen, the principal DTG peak shifted from 346.3 to 364.9 °C with increasing heating rate, while residual mass at 500 °C increased from 21.5 to 27.1%. Under synthetic air, the principal mass-loss event occurred at lower temperatures and was followed by a distinct high-temperature oxidative event accompanied by a strong exothermic DSC response residual mass at 500 °C was 4.6 ± 6.4% and 4.5 ± 3.5% at 10 and 25 °C min−1, respectively. Kissinger apparent activation energies were 263.6 kJ mol−1 under nitrogen and 189.5 kJ mol−1 under synthetic air. Iso-conversional OFW and KAS analyses showed a more consistent kinetic response under nitrogen, whereas synthetic-air data exhibited greater variability and lower regression linearity. The results demonstrate that atmosphere and heating rate substantially influence the thermal response of Norway spruce and provide material-scale experimental constraints for the development and subsequent calibration of solid-phase fire models incorporating both primary wood degradation and oxidative consumption of the resulting solid residue.