Ruiqi Li

Mr. Ruiqi Li

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2026 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
RLRuiqi Li
Ruiqi Li
HHHaixiao Hu
Haixiao Hu
KZKaiDong Zheng
KaiDong Zheng
HCHongda Chen
Hongda Chen
HLHaonan Liu
Haonan Liu
SLShuxin LI
Shuxin LI

15 January 2026 in Polymers
Verified
Journal Article
Open access
PDF file
GHGuangming Huo
Guangming Huo
YZyu zhang
yu zhang
XHXia Han
Xia Han
HLHaonan Liu
Haonan Liu
XYXiaoyu Yan
Xiaoyu Yan
HCHongda Chen
Hongda Chen
Hydrogen permeation parameters of PA12 were obtained through high-pressure hydrogen permeation experiments conducted under various temperature and pressure conditions. The temperature-dependent mechanism governing the hydrogen permeation behavior of PA12 was further examined using dynamic mechanical analysis (DMA). A multi-field coupled numerical model was established and validated against the experimental results. Based on the validated numerical approach, the hydrogen permeation behavior of a type IV hydrogen storage vessel with local reinforcement was investigated. The results show that both temperature and pressure have a significant influence on the hydrogen permeation performance of PA12. When the temperature is below the glass transition temperature (Tg) of PA12 (48.34 °C), the diffusion coefficient remains low, whereas temperatures above the Tg led to a marked increase in the diffusion coefficient. In addition, the local reinforcement patch effectively prolongs the time required to reach steady-state permeation, reduces the hydrogen permeation flux before and after steady state, and enhances the overall resistance to hydrogen permeation of the type IV vessel. As the diffusion coefficient of the liner material increases, the hydrogen diffusion rate increases substantially, leading to greater hydrogen accumulation in the dome region and higher permeation levels both before and after steady state. These findings provide theoretical guidance and design references for optimizing the hydrogen-resistant performance of type IV hydrogen storage vessels.

7 June 2026 in Composite Structures
Verified
Journal Article
Closed access
RLRuiqi Li
Ruiqi Li
HHHaixiao Hu
Haixiao Hu
JZJinchun Zhu
Jinchun Zhu
DCDongfeng Cao
Dongfeng Cao
KZKaidong Zheng
Kaidong Zheng
SLShuxin LI
Shuxin LI

5 March 2026 in Polymers
Verified
Journal Article
Open access
PDF file
RLRuiqi Li
Ruiqi Li
KZKaidong Zheng
Kaidong Zheng
XYXiaoyu Yan
Xiaoyu Yan
HLHaonan Liu
Haonan Liu
YZyu zhang
yu zhang
SLShuxin LI
Shuxin LI
Hydrogen storage vessels are critical components in hydrogen energy systems, and improving their manufacturing efficiency and structural performance is essential for next-generation Type IV vessel designs. Compared with conventional wet filament winding, towpreg dry filament winding offers higher efficiency, reduced environmental impact, and better adaptability to complex structures. In this study, key process parameters, including winding tension, heating temperature, and winding speed were systematically optimized using the tensile strength and interlaminar shear strength of NOL ring specimens as evaluation metrics. A response surface methodology (RSM) regression model was established to correlate process variables with mechanical properties, followed by multi-objective optimization using the non-dominated sorting genetic algorithm II (NSGA-II) and final parameter selection through the Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) method. The results indicate that shear strength is primarily affected by heating temperature, whereas tensile strength is mainly governed by winding tension. The optimal parameter combination (79 N, 360 °C, and 11 m/min) yielded tensile and shear strengths of 2462.2 MPa and 64.4 MPa, respectively, with prediction errors below 0.5%. A 9 L Type IV hydrogen storage vessel manufactured under these conditions showed approximately 15.4% lower mass and about 17% higher gravimetric hydrogen storage efficiency than a comparable wet wound vessel.