Kaidong Zheng

Dr. Kaidong Zheng

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2022 in Materials
Verified
Journal Article
Open access
PDF file
XWXiangjiang Wang
Xiangjiang Wang
YWYao Wang
Yao Wang
YJYundong Ji
Yundong Ji
HHHaixiao Hu
Haixiao Hu
DCDongfeng Cao
Dongfeng Cao
SLShuxin Li
Shuxin Li
Thin-ply composite failure modes also significantly differ from conventional ply composite failure modes, with the final failure mechanism switching from irregular progressive failure to direct fracture characterized by a uniform fracture with the reduction of the ply thickness. When open holes and bolt joints are involved, thin-ply-laminated composites exhibit more complex stress states, damage evolution, and failure modes. Compared to the experimental study of thin-ply-laminated composite-bolted joints, there are few reports about numerical analysis. In order to understand the damage evolution and failure mechanism of thin-ply-laminated composites jointed by single-lap bolt, a progressive damage model based on three-dimensional (3D) LaRC failure criterion combined with cohesive element is constructed. Through an energy-based damage evolution method, this model can capture some significant mechanical characteristics in thin-ply-laminated structures, such as the in situ effect, delamination inhibition, and fiber compressive kinking failure. The comparisons between the numerical predictions and experimental observations are made to verify the accuracy of the proposed model. It is found that the predicted stress-displacement curves, failure modes, damage morphologies, etc., are consistent with the experimental results, indicating that the presented progressive damage analysis method displays excellent accuracy. The predicted stress at the onset of delamination is 50% higher than that of the conventional thick materials, which is also consistent with experimental results. Moreover, the numerical model provides evidence that the microstructure of thin-ply-laminated composite performs better in uniformity, which is more conducive to inhibiting the intra-layer damage and the expansion of delamination damage between layers. This study on the damage inhibition mechanism of thin-ply provides a potential analytical tool for evaluating damage tolerance and bearing capabilities in thin-ply-laminated composite-bolted joints.

15 January 2026 in Polymers
Verified
Journal Article
Open access
PDF file
GHGuangming Huo
Guangming Huo
YZyu zhang
yu zhang
XHXia Han
Xia Han
HLHaonan Liu
Haonan Liu
XYXiaoyu Yan
Xiaoyu Yan
HCHongda Chen
Hongda Chen
Hydrogen permeation parameters of PA12 were obtained through high-pressure hydrogen permeation experiments conducted under various temperature and pressure conditions. The temperature-dependent mechanism governing the hydrogen permeation behavior of PA12 was further examined using dynamic mechanical analysis (DMA). A multi-field coupled numerical model was established and validated against the experimental results. Based on the validated numerical approach, the hydrogen permeation behavior of a type IV hydrogen storage vessel with local reinforcement was investigated. The results show that both temperature and pressure have a significant influence on the hydrogen permeation performance of PA12. When the temperature is below the glass transition temperature (Tg) of PA12 (48.34 °C), the diffusion coefficient remains low, whereas temperatures above the Tg led to a marked increase in the diffusion coefficient. In addition, the local reinforcement patch effectively prolongs the time required to reach steady-state permeation, reduces the hydrogen permeation flux before and after steady state, and enhances the overall resistance to hydrogen permeation of the type IV vessel. As the diffusion coefficient of the liner material increases, the hydrogen diffusion rate increases substantially, leading to greater hydrogen accumulation in the dome region and higher permeation levels both before and after steady state. These findings provide theoretical guidance and design references for optimizing the hydrogen-resistant performance of type IV hydrogen storage vessels.

5 November 2025 in Polymer Composites
Verified
Journal Article
Closed access
KZKaidong Zheng
Kaidong Zheng
HCHongda Chen
Hongda Chen
YZYu Zhang
Yu Zhang
XYXiaoyu Yan
Xiaoyu Yan
HHHaixiao Hu
Haixiao Hu
SLShuxin Li
Shuxin Li

5 March 2026 in Polymers
Verified
Journal Article
Open access
PDF file
RLRuiqi Li
Ruiqi Li
KZKaidong Zheng
Kaidong Zheng
XYXiaoyu Yan
Xiaoyu Yan
HLHaonan Liu
Haonan Liu
YZyu zhang
yu zhang
SLShuxin LI
Shuxin LI
Hydrogen storage vessels are critical components in hydrogen energy systems, and improving their manufacturing efficiency and structural performance is essential for next-generation Type IV vessel designs. Compared with conventional wet filament winding, towpreg dry filament winding offers higher efficiency, reduced environmental impact, and better adaptability to complex structures. In this study, key process parameters, including winding tension, heating temperature, and winding speed were systematically optimized using the tensile strength and interlaminar shear strength of NOL ring specimens as evaluation metrics. A response surface methodology (RSM) regression model was established to correlate process variables with mechanical properties, followed by multi-objective optimization using the non-dominated sorting genetic algorithm II (NSGA-II) and final parameter selection through the Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) method. The results indicate that shear strength is primarily affected by heating temperature, whereas tensile strength is mainly governed by winding tension. The optimal parameter combination (79 N, 360 °C, and 11 m/min) yielded tensile and shear strengths of 2462.2 MPa and 64.4 MPa, respectively, with prediction errors below 0.5%. A 9 L Type IV hydrogen storage vessel manufactured under these conditions showed approximately 15.4% lower mass and about 17% higher gravimetric hydrogen storage efficiency than a comparable wet wound vessel.