When the solar-storage DC microgrid operates in islanded mode, the battery needs to stabilize the bus voltage and keep the state of charge (SOC) balanced in order to extend the service life of the battery and the islanded operation time. When there are multiple energy storage units in the DC microgrid, it is necessary to solve the problem of unbalanced circulation and the state of charge between batteries using a reasonable droop control method. In this paper, firstly, the DC–DC charging and discharging circuit of the battery is designed, and the unbalanced SOC of the battery caused by the different impedances of the line is analyzed. Secondly, an adaptive droop control method is proposed to solve the problems of SOC imbalance and current circulation between the batteries. Thirdly, based on MATLAB/SIMULINK R2021b simulation software, the proposed control method is modeled and simulated. Compared with the traditional droop control, the effectiveness of the proposed method is validated.
In order to enhance the carbon emission reduction capability and economy of the microgrid, a capacity optimization configuration method considering laddered carbon trading and demand response is proposed for a grid-connected microgrid consisting of photovoltaic, battery and hydrogen storage devices. Combined with the mathematical model and system structure of each unit in the microgrid, the integrated operation control strategy is determined in this paper. A demand response model containing three load types is developed to reduce the stress on the storage and generation side. A carbon-trading mechanism is introduced into the operating costs to establish a configuration model with annual overall profit and power supply reliability as the optimization objectives. The non-dominated sorting genetic algorithm II is used to optimize the capacity of each unit, and the effectiveness of this model is verified by taking a microgrid in a region in Northwest China as an example to analyze the impacts of ladder carbon trading and demand response on the configuration results and system operation.
MoS2 nanomaterials and ionic liquids (ILs) have attracted tremendous interest as the prime electrodes and electrolytes of supercapacitors. However, the corresponding charge storage mechanisms have not yet been clearly understood. Herein, we study the molecular-level energy storage mechanisms of the MoS2 electrode in imidazolium ionic liquid ([BMI+][PF6−]) using molecular dynamics (MD) simulation. The electric double-layer (EDL) structures of MoS2 electrodes in [BMI+][PF6−] electrolytes are comprehensively studied in terms of number density, MD snapshots, separation coefficient, and ion-electrode interaction energy. Based on this, the electric potential and electric field distributions are calculated by integrating Poisson equations. Importantly, a bell-shaped differential capacitance profile is proposed, different from the U-shaped curve from the conventional Gouy–Chapman theory. Especially, it can be well reproduced by the differential charge density curve in the Helmholtz layer. This indicates that the capacitive behaviors of the MoS2 electrode are primarily determined by the counterion population/structure in the EDL region 5.0 Å from the electrode surface. In the end, ion diffusion coefficients within different interfacial EDL regions are evaluated, revealing that dynamics are significantly suppressed by ~50% in the Helmholtz region. However, the dynamics can be recovered to a bulk state with the ion position 10 Å away from the electrode surface. The as-obtained insights reveal the charge storage mechanisms of MoS2 in ILs, which can provide useful guidance on improving the energy density of MoS2 supercapacitors.
Planar perovskite solar cells (PSCs), as a promising photovoltaic technology, have been extensively studied, with strong expectations for commercialization. Improving the power conversion efficiency (PCE) of PSCs is necessary to accelerate their practical application, in which the electron transport layer (ETL) plays a key part. Herein, a single-anchored ligand of phenylphosphonic acid (PPA) is utilized to regulate the chemical bath deposition of a TiO2 ETL, further improving the PCE of planar PSCs. The PPA possesses a steric benzene ring and a phosphoric acid group, which can inhibit the particle aggregation of the TiO2 film through steric hindrance, leading to optimized interface (ETL/perovskite) contact. In addition, the incorporated PPA can induce the upshift of the Fermi-level of the TiO2 film, which is beneficial for interfacial electron transport. As a consequence, the PSCs with PPA-TiO2 achieve a PCE of 24.83%, which is higher than that (24.21%) of PSCs with TiO2. In addition, the unencapsulated PSCs with PPA-TiO2 also exhibit enhanced stability when stored in ambient conditions.
Photovoltaic (PV) power stations are pivotal for the renewable energy transition, yet their operational efficiency is often compromised by defects such as surface dust accumulation and cracks. Traditional manual inspections are labor-intensive and subjective, while conventional monitoring methods struggle with environmental interference. This study proposes YOLO-MSG, a lightweight framework specifically designed for the automated detection of PV module defects during system operation, including normal panels as well as defective conditions such as dusty and cracked panels. The methodology integrates a Multi-Scale Grouped Convolution (MSGC) module for enhanced feature extraction and a Group-Stem Decoupled Head (GSD-Head) to reduce parameter redundancy. Furthermore, a joint optimization strategy involving LAMP and logits-based knowledge distillation is employed to facilitate edge deployment. Experimental results on a specialized PV defect dataset demonstrate that YOLO-MSG achieves a superior balance between detection accuracy and computational cost. Compared to state-of-the-art models like YOLO11 and YOLOv12, YOLO-MSG significantly reduces GFLOPs and parameter count while maintaining highly competitive mean Average Precision (mAP), with improvements of 1.35% in mAP and 2.37% in mAP50-95 over the baseline models. Specifically, the model achieves an average inference speed of 90.30 FPS on the NVIDIA Jetson AGX platform. These findings confirm the algorithm’s industrial viability, providing a robust and efficient solution for the real-time automated maintenance of photovoltaic infrastructures.
With economic growth, constructing photovoltaic power plants on gangue mountains holds significant potential for the development of renewable energy and the effective utilization of gangue mountains. However, it is crucial to account for the impact of the spontaneous combustion of coal gangue on surface structures and the mechanical performance of pile foundations. This study uses COMSOL Multiphysics software (version 6.2) to conduct a simulation by establishing a multiphysical coupling model of the temperature field, oxygen concentration field, and seepage velocity field, simulating the dynamic evolution of spontaneous combustion in gangue mountains. The reasonableness of the model was verified by comparison, and a mechanics module was added to explore the effects of pile foundations and ground surfaces at high temperatures. The results indicate that the spontaneous combustion of coal gangue initially generates high-temperature regions beneath the slope of the pile, which gradually expand outward. Due to thermal expansion, thermal stress and displacement occur in both the gangue mountain and pile foundations, potentially compromising the stability of the foundations and increasing the risk of structural failure. These findings can serve as valuable references for the construction of photovoltaic power plants and the effective utilization of gangue mountains.