TiOxNy coatings are known for their good biocompatibility and corrosion resistance and have been previously explored for biomedical applications, including cardiovascular stents. In this work, emphasis is placed on a systematic investigation of the effect of substrate bias voltage on the structural, morphological, and mechanical properties of TiOxNy films deposited by reactive magnetron sputtering. TiOxNy coatings were deposited on 316L stainless steel substrates using a pure titanium target (99.99%) in an Ar–N2–O2 gas mixture at various substrate bias voltages (0 to −150 V). The influence of substrate bias on the deposition rate, structure, and mechanical properties of the films was investigated. X-ray diffraction (XRD) analysis revealed the sequential phase evolution from cubic TiN to oxynitride TiON and further to TiO2 (anatase/rutile) with increasing negative substrate bias, indicating that ion bombardment energy plays a decisive role in determining the crystallinity and phase composition of the coatings. The coating deposited at −50 V exhibited the highest hardness (~430 HV) and good adhesion strength (critical load 20–25 N). Contact angle measurements confirmed the hydrophilic behavior of the coatings, which is favorable for biomedical applications.
This study investigates the influence of preliminary severe plastic deformation on the efficiency of ion-plasma nitriding (IPN) and the formation of a nitrided layer in 12Kh18N10T austenitic stainless steel. Two types of surface mechanical treatment were compared: vibro-impact ball mechanical treatment (VIMT) and ultrasonic nanocrystalline surface modification (UNSM). After the preliminary treatments, the samples were subjected to ion-plasma nitriding at 500 °C for 10 h using ammonia (NH3) as the working gas. The phase composition, microstructure, elemental distribution, surface roughness, microhardness, and scratch resistance were analyzed using X-ray diffraction (XRD), scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) analysis, profilometry, instrumented indentation, and progressive scratch testing. The results show that both types of preliminary treatment promote the formation of a nitrogen-enriched diffusion layer. The UNSM-treated samples exhibited more pronounced peak broadening and shifting in XRD patterns, indicating a higher level of lattice distortion and nitrogen supersaturation. The maximum nitrogen concentration in the near-surface region reached 15.56 wt.%. Microhardness increased significantly after nitriding for both treatments. Under the selected processing conditions, the UNSM + IPN samples demonstrated a thicker diffusion layer, lower surface roughness, and higher critical loads in scratch testing, indicating improved resistance to surface damage compared with VIMT + IPN samples. The obtained results highlight the important role of the defect structure formed during preliminary treatment in controlling nitrogen diffusion and the resulting mechanical and tribological properties of ion-plasma nitrided austenitic stainless steel.
This study investigates the effect of the gas mixture composition ratio (Ar:N2:O2) during magnetron sputtering on the morphology, phase composition, and visual characteristics of TiNxOy thin films. Five different modes were used with a variable N2:O2 ratio ranging from 0.5 to 3. The resulting coatings exhibited noticeable differences in color—from golden to dark blue—which correlates with changes in chemical composition and phase state. The morphology of the films, examined by scanning electron microscopy (SEM), varied from a dense to a columnar structure. These results demonstrate that the properties of TiON coatings can be controlled by adjusting the N2:O2 ratio: nitrogen-rich conditions promote denser coatings with higher hardness and improved wear resistance, whereas a balanced N2:O2 ratio enhances coating adhesion to the substrate.
Ti–6Al–4V is the primary titanium alloy for aerospace, biomedical, and additive manufacturing applications; however, the high cost of powders produced by atomization limits their widespread adoption. This study aims to develop a cost-effective method for producing chemically homogeneous pre-alloyed Ti–6Al–4V powders from titanium sponge. A combined process is proposed, involving the hydrogenation of titanium sponge, mechanical alloying of the hydride phase with Al and V powders, and subsequent vacuum dehydrogenation. The formation of the brittle δ-TiH2 phase facilitated intensive material comminution and effective distribution of the alloying elements. According to laser diffraction data, the median particle size decreased from 450 to 30–35 µm. X-ray diffraction (XRD) analysis confirmed the sequential α-Ti → δ-TiH2 transition and the formation of a stable α + β two-phase structure characteristic of Ti–6Al–4V following dehydrogenation. SEM observations demonstrated that the final powders predominantly consist of individual fractured particles with limited hard agglomeration, favorable for powder flowability and compaction behavior. EDS analysis indicated a relatively homogeneous microscale distribution of Al and V without observable large-scale segregation. The synthesized powders exhibited low impurity levels, with O < 0.07 wt.% and H < 0.02 wt.%. The developed approach represents a promising and economical alternative to expensive atomization techniques for powder metallurgy and additive manufacturing.
This study investigates titanium oxynitride (TiOxNy) coatings deposited by reactive magnetron sputtering on 316L stainless steel substrates in an Ar–N2–O2 gas mixture at a fixed N:O ratio of 1.6. The coatings were deposited under three reactive magnetron sputtering regimes with Ar flow rates of 33, 28, and 26 sccm and corresponding substrate biases of −50, −100, and −150 V, respectively, while the N2 and O2 flow rates were kept constant at 10 and 6 sccm. The coatings exhibited a dense microstructure, with thicknesses ranging from 2.13 to 5.51 μm. X-ray diffraction analysis revealed the formation of a multiphase structure comprising TiN, TiOxNy, and TiO. The deposition regime had a significant influence on the functional properties of the coatings. The lowest friction coefficients (µ ≈ 0.26–0.28) and stable tribological behavior were characteristic of the Ar26 sample. The highest corrosion resistance was observed for the Ar28 sample, with a corrosion current density of icorr = 2.82 × 10−7 A/cm2 and a corrosion rate of vcorr = 0.00573 mm/year. All coatings exhibited hydrophilic surface behavior, with contact angles of 50–57°, which may be relevant for further evaluation in biomedical surface applications. Thus, the structure and functional properties of TiOxNy coatings can be regulated by selecting an appropriate deposition regime, including the Ar flow rate, relative reactive gas fraction, and substrate bias. However, additional biological tests, including cytotoxicity, hemocompatibility, endothelialization, and platelet adhesion studies, are required before conclusions about vascular implant applicability can be made.
Although the duty cycle is an important parameter in pulsed plasma nitriding, its role in simultaneously controlling the microstructure, mechanical performance, tribological behavior, and corrosion resistance of 12Kh18N10T stainless steel remains insufficiently understood. Therefore, this study systematically investigates these relationships under otherwise fixed nitriding conditions. The samples were nitrided at 500 °C, a pressure of 400 Pa, a voltage of 700 V, and a treatment duration of 5 h, with duty cycle (DC) values of 30, 60, and 90%. The surface microstructure and composition were characterized by scanning electron microscopy, energy-dispersive spectroscopy, and X-ray diffraction. The mechanical properties were evaluated by instrumented nanoindentation, the tribological properties were evaluated using the coefficient of friction and wear rate, and the corrosion resistance was investigated using potentiodynamic polarization. The maximum nitrided layer thickness of 91.29 μm was obtained at DC30, whereas the layer thickness at DC60 and DC90 was approximately 65.07 μm. Fe4N and Cr2N phases were identified in all samples. The DC60 regime provided the highest hardness of 740.6 HV, an elastic modulus of 215.9 GPa, the lowest coefficient of friction of 0.333, and the lowest corrosion current density of 0.000665 mA/cm2. The minimum wear rate of 2.276 × 10−5 mm3/(N·m) was achieved at DC90. These results show that the optimal processing condition depends on the required combination of hardness, wear resistance, coefficient of friction, and corrosion resistance. The obtained results demonstrate that the functional properties of the steel can be effectively tailored by controlling the duty cycle.