Francisco Elizalde-Blancas

Prof. Dr. Francisco Elizalde-Blancas


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2012 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
JLJosemanuel Luna-Nemecio
Josemanuel Luna-Nemecio
RRRicardo Romero-Mendez
Ricardo Romero-Mendez
AHAbel Hernandez-Guerrero
Abel Hernandez-Guerrero
FEFrancisco Elizalde-Blancas
Francisco Elizalde-Blancas
Based on the fact that malignant cancerous lesions (neoplasms) develop high metabolism and use more blood supply than normal tissue, infrared thermography (IR) has become a reliable clinical technique used to indicate noninvasively the presence of cancerous diseases, e.g., skin and breast cancer. However, to diagnose cancerous diseases by IR, the technique requires procedures that explore the relationship between the neoplasm characteristics (size, blood perfusion rate and heat generated) and the resulting temperature distribution on the skin surface. In this research work the dual reciprocity boundary element method (DRBEM) has been coupled with the simulated annealing technique (SA) in a new inverse procedure, which coupled to the IR technique, is capable of estimating simultaneously geometrical and thermophysical parameters of the neoplasm. The method is of an evolutionary type, requiring random initial values for the unknown parameters and no calculations of sensitivities or search directions. In addition, the DRBEM does not require any re-meshing at each proposed solution to solve the bioheat model. The inverse procedure has been tested considering input data for simulated neoplasms of different sizes and positions in relation to the skin surface. The successful estimation of unknown neoplasm parameters validates the idea of using the SA technique and the DRBEM in the estimation of parameters. Other estimation techniques, based on genetic algorithms or sensitivity coefficients, have not been capable of obtaining a solution because the skin surface temperature difference is very small.

27 April 2018 in Energies
Verified
Journal Article
Open access
PDF file
JGJuan Garcia
Juan Garcia
José Manuel Riesco-AvilaJosé Manuel Riesco-Avila
José Manuel Riesco-Avila
FEFrancisco Elizalde-Blancas
Francisco Elizalde-Blancas
Juan Manuel BelmanJuan Manuel Belman
Juan Manuel Belman
Juan Serrano-ArellanoJuan Serrano-Arellano
Juan Serrano-Arellano
Flow maldistribution represents a problem of particular interest in the engineering field for several thermal systems. In flat plate solar collectors, the thermal efficiency strongly depends on the flow distribution through the riser tubes, where a uniform distribution causes a uniform temperature distribution and therefore a higher efficiency. In this work, a Computational Fluid Dynamics (CFD) numerical analysis has been carried out using the commercial software FLUENT®, in order to determine the flow distribution, pressure drop and hence the thermal efficiency of a solar collector with distribution flow plates inside the manifolds. The obtained numerical solution for this type of thermal systems has been validated with experimental results available in literature for laminar and turbulent flow. Four distribution plate configurations were analyzed. Results show that using two distribution plates in each of both manifolds improves the flow uniformity up to 40% under the same operating conditions when distribution plates are not used. Besides, it is shown that there exists an increase in the overall pressure drop which is practically negligible for the tilt angles commonly employed in the installation of flat plate solar collectors in Mexico. The use of closed end distribution plates on the dividing and combining manifolds allows the thermal efficiency to become close to the ideal thermal efficiency which is obtained with a uniform flow distribution.

5 March 2019 in Energies
Verified
Journal Article
Open access
PDF file
Juan Manuel BelmanJuan Manuel Belman
Juan Manuel Belman
DPDiana Pardo-Cely
Diana Pardo-Cely
FEFrancisco Elizalde-Blancas
Francisco Elizalde-Blancas
AGArmando Gallegos-Muñoz
Armando Gallegos-Muñoz
Vicente Pérez-GarcíaVicente Pérez-García
Vicente Pérez-García
MMMIGUEL ANGEL GOMEZ MARTINEZ
MIGUEL ANGEL GOMEZ MARTINEZ
This work presents the main behaviors shown in the habits of consumers of domestic refrigerators, which influences the energy consumption of this appliance. This study is based on a series of surveys answered by 200 consumers from four cities in the State of Guanajuato, Mexico. The questions were arranged with the aim of evaluating the general characteristics and usage habits such as refrigerator age, door opening frequency, damper position, load of food supplies, external and internal cleaning habits, and nearby heat sources, among other things. The randomly interviewed consumers were individuals between 20 and 60 years of age, who were interviewed using handmade surveys by experts in the field of refrigeration. In some cases, photographic evidence was gathered from the consumers’ refrigerators to represent the typical usage habits. In general, the results show that better usage habits are necessary from an energy point of view. Most consumers agree with adopting best practices for using their refrigerator.

6 April 2023 in Entropy
Verified
Journal Article
Open access
PDF file
José de Jesús Ramírez-MinguelaJosé de Jesús Ramírez-Minguela
José de Jesús Ramírez-Minguela
Victor Rangel-HernandezVictor Rangel-Hernandez
Victor Rangel-Hernandez
J. Arturo Alfaro-AyalaJ. Arturo Alfaro-Ayala
J. Arturo Alfaro-Ayala
FEFrancisco Elizalde-Blancas
Francisco Elizalde-Blancas
BCBeatriz Ruiz Camacho
Beatriz Ruiz Camacho
Carlos Enrique Alvarado-RodriguezCarlos Enrique Alvarado-Rodriguez
Carlos Enrique Alvarado-Rodriguez
In this work, a numerical analysis of three different flat plate solar collectors was conducted using their entropy generation rates. Specifically, the Computational Fluid Dynamics (CFD) technique was used to compare the detailed performance of conventional and zigzag tube geometries of flat plate solar collectors (FPCs) in terms of their entropy generation rates. The effects of fluid viscosity, heat transfer, and heat loss of the flat plate solar collectors were considered for the local and global entropy generation rate analyses. Variations on the inlet volumetric flow rate of the FPCs from 1.0 to 9.0 L/min were simulated under the average solar radiation for one year in the state of Guanajuato, Mexico. The results illustrate and discuss the temperatures, pressures, and global entropy generation rates for volumetric flow variations. The velocity, temperature, and pressure distributions and the maps of the local entropy generation rates inside the collectors are presented and analyzed for the case with a flow rate of 3.0 L/min. These results demonstrate that the zigzag geometries achieved higher outlet temperatures and greater entropy generation rates than the conventional geometry for all the volumetric flow rates considered.

1 March 2016 in Journal of Power Sources
Verified
Journal Article
Closed access
IRIsaac P. Raya
Isaac P. Raya
MEMichael W. Ellis
Michael W. Ellis
AHAbel Hernandez-Guerrero
Abel Hernandez-Guerrero
FEFrancisco Elizalde-Blancas
Francisco Elizalde-Blancas

6 June 2018
Verified
Book Chapter
Open access
PDF file
Victor Rangel-HernandezVictor Rangel-Hernandez
Victor Rangel-Hernandez
ANAndrés M. Niño-Avendaño
Andrés M. Niño-Avendaño
JRJosé J. Ramírez-Minguela
José J. Ramírez-Minguela
Juan Manuel BelmanJuan Manuel Belman
Juan Manuel Belman
FEFrancisco Elizalde-Blancas
Francisco Elizalde-Blancas
In this chapter, an exergy analysis applied to a solid oxide fuel cell (SOFC)/vapor adsorption refrigeration (VAR) system is presented. The influences of four significant parameters (current density, inlet fuel temperature, fuel utilization and steam-to-carbon ratio) on the exergy efficiency of both the SOFC stack and the SOFC-VAR system are investigated. In order to do so, a mathematical model is constructed in Engineering Equation Solver (EES) software to generate the simulations. The analysis shows that the calculated exergy efficiency is around 8% lower than the energy efficiency for both cases. Moreover, it is found that most of the causes of irreversibilities in the system are due to electronic and ionic conduction in the components. It is also shown that the exergy efficiency is substantially sensitive to fuel inlet temperature, which is evidenced by a bending-over behavior. Finally, in accordance with the calculated efficiency defects, the main exergy destructions are present in the heat exchangers, the SOFC, the afterburner and the generator.