This study was conducted to study the redistribution of internal force and the development of the plastic hinge of an MBS with foundations at two different elevations considering the torsional effect. The results indicate that the redistribution of the base shear of MBS is evident at different embedding ends, and the redistribution of story shear on different floors also took place. The redistribution of the shear force of columns is different at the upper- and lower-embedding sides, and the internal force redistribution is more prominent along the slope direction. Consequently, the redistribution of the internal force of MBS should be considered in practical seismic design. Furthermore, the damage of MBS is transferred from the floors above the upper-embedding end to the floors under the upper-embedding end with the increase in the seismic intensity, where the elements at the floors above the upper-embedding end suffer the most serious damage, and the damage is unevenly distributed in the upper-embedding story and the adjacent upper story. The lower-embedding column is more prone to hinge across the slope direction because of the torsional effect. With changes, the redistributions of the shear force of the base, story, and column are different. A larger would result in a weaker redistribution of base shear. The redistribution of the story shear of the 1st floor and its columns along the slope direction shows an increasing-decreasing tendency with the increase in , and the redistribution is the most serious when is 0.4. While across the slope direction, the redistribution of the story shear tends to be weakened as increases. The forming of the plastic hinge of single-frames along the slope direction is related to and , especially the damage of the upper-embedding columns. The torsional effect has a significant influence on the damage of the single-frames across the slope direction. Some measures should be taken to improve the bearing capacity of the upper embedding columns and columns on floors under the upper-embedding end, as well as the drift ductility of the upper-embedding columns.
This study focuses on the fundamental mechanical behavior of frame–shear wall split-foundation structures with shear walls at both upper and lower ground ends, investigating their basic mechanical characteristics, internal force redistribution patterns, and the influencing factor of intra-stiffness ratio on seismic performance. From the analysis results, it can be found that the relative drop height of frame–shear wall split-foundation structures significantly affects their internal force patterns. Shear-bending stiffness should be adopted in stiffness calculations to reflect the stiffness reduction effect of drop height on lower embedding shear walls. In frame–shear wall split-foundation structures, the existence of drop height causes upper embedding columns to experience more unfavorable stress conditions compared to lower embedding shear walls, potentially preventing lower embedding shear walls from serving as the primary seismic defense line. Strengthening lower embedding shear walls to reduce the intra-stiffness ratio can mitigate this issue. Performance evaluation under bidirectional rare earthquakes shows greater along-slope directional damage than cross-slope directional damage. Increasing shear wall length to reduce the intra-stiffness ratio improves component rotation-based performance, but shear strain-based evaluation of upper embedding shear walls indicates a limited improvement in shear capacity. Special attention should therefore be paid to along-slope directional shear capacity of upper embedding shear walls during structural design.
12 December 2019 in NED University Journal of Research
One of key issues of designing connected structure is the design of the connecting body between towers. This paper presents the analysis of different connecting body design schemes based on a 202.15 m (663 ft) twin-tower ultra-high-rise structure connected by a connecting truss. The influence of height and type of connection on the entire building structure was studied by comparing storey shear forces and drift of structure. The results indicated that the connection type between the connecting body and main structure has little influence on the building structure performance. Finite element analysis of the connecting body indicated that the internal force characteristic of rigid connection type is better compared to the hinge connection type. Furthermore, the connecting truss design based on inclined braces connected by hinge joint is superior compared to the rigid joints.
To address the problems of easy cracking and the difficulty in balancing construction schedule and structural quality in the construction of ultra-long concrete slabs, this paper takes the ultra-long floor slab project of an inpatient building in the Science City Campus of Chongqing University Cancer Hospital as the research object, and conducts research on temperature and crack control in the construction of the alternative bay method. The key structural mechanical parameters are determined through theoretical calculation. The temperature and deformation changes during the whole process of concrete pouring are tracked by combining on-site monitoring and finite element simulation, and the effects of different construction parameters are compared and analyzed. The results show that when the alternative bay method is adopted, the overall temperature distribution of the floor slab is uniform, and there are obvious differences in deformation at different positions. The center of the first-poured slab has smaller deformation, the beam side has larger deformation, the later-poured slab has larger overall deformation, and tensile deformation occurs on both sides of the construction joint. Reasonably dividing the pouring blocks, optimizing the pouring sequence and extending the pouring interval can significantly reduce the tensile deformation of concrete and alleviate stress concentration. This study confirms that the alternative bay method can effectively reduce the risk of temperature-induced cracking in ultra-long floor slabs and provide technical reference for seamless construction of similar above-ground structures.