Dehui Ji

Dr. Dehui Ji


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2022 in Materials
Verified
Journal Article
Open access
PDF file
QHQiang Hu
Qiang Hu
DJDehui Ji
Dehui Ji
Ming-xue ShenMing-xue Shen
Ming-xue Shen
HZHui Zhuang
Hui Zhuang
HaiLong YaoHaiLong Yao
HaiLong Yao
YZYouliang Zhang
Youliang Zhang
Carbide coatings are frequently used to improve the wear resistance of industrial components in various wear environments. In this research, aiming at the service characteristics of easy wear and short service life of ball mill liners, WC–10Cr3C2–12Ni coatings were prepared by supersonic flame spraying technology (HVOF). The reciprocating sliding tests were conducted under four different WC particle size conditions, and the differences in the tribological behavior of the coatings and three–body abrasive wear mechanism were obtained. The findings reveal that the average nanohardness of the WC–Cr3C2–Ni coating is nearly five times greater than that of the steel substance. The COF of tribo-pairs decreases and then increases as the particle size increases. In the case of no particles, the surface of the coating is slightly worn, with fatigue and oxidative wear being the primary wear mechanisms. Small particles (1.5 μm and 4 μm) are crushed and coated on the coating surface, in which the extremely fine particles are plasticized to form friction layers that have a protective effect on the coatings. The protective effect of the particles disappears as the particle size increases and is replaced by a powerful chiseling effect on the coatings, resulting in serious material loss. The particle size has a direct relationship with coating wear.

30 September 2021 in Polymers
Verified
Journal Article
Open access
PDF file
ZHZirui Huang
Zirui Huang
MZMeiling Zhong
Meiling Zhong
HYHaibo Yang
Haibo Yang
EXEnqin Xu
Enqin Xu
DJDehui Ji
Dehui Ji
RZRichao Zhang
Richao Zhang
The isothermal crystallization of poly(l-lactide) (PLLA) has been investigated by in-situ wide angle X-ray diffraction (WAXD) and polarized optical microscopes (POM) equipped with a hot-stage accessory. Results showed that the spherulites of PLLA were formed at high temperature, whereas irregular morphology was observed under a low temperature. This can be attributed to the varying rates of crystallization of PLLA at different temperatures. At low temperatures, the nucleation rate is fast and hence the chains diffuse very slow, resulting in the formation of imperfect crystals. On the other hand, at high temperatures, the nucleation rate is slow and the chains diffuse fast, leading to the formation of perfect crystals. The change in the value of the Avrami exponent with temperature further verifies the varying trend in the morphological feature of the crystals.

28 September 2026 in Lubricants
Verified
Journal Article
Open access
PDF file
NYNie Yanjiao
Nie Yanjiao
JSJinhao Shao
Jinhao Shao
LXLi Xiao
Li Xiao
WDWenhao Dai
Wenhao Dai
DJDehui Ji
Dehui Ji
LKLiMei Kang
LiMei Kang
The pantograph–catenary system serves as the core power supply device, ensuring stable operation of high-speed trains, and its contact interface represents a typical current-carrying friction system, where the introduction of electric current significantly complicates the wear mechanisms. The coupling effect of mechanical wear and electrical wear exacerbates damage to and degradation of carbon strip materials, while electric arcs induced by unstable contact states directly regulate the tribological characteristics and electrical conductivity of the friction pair. To investigate the current-carrying friction and wear behavior of carbon strips under the dominant effect of electric arcs, this study simulated the irregularity conditions of contact wires, observed the evolution characteristics of electric arcs, and systematically analyzed the effects of test current and contact load on the damage characteristics and current-carrying performance of the contact pair. The results indicate that arc morphology exhibits differentiated characteristics across friction cycles, with significant fluctuations in arc intensity. Regarding the friction coefficient, under a contact load of 25 N, the friction coefficients corresponding to currents of 0 A, 40 A, and 80 A are 0.378, 0.242, and 0.335, respectively; under a contact load of 50 N, the corresponding values are 0.432, 0.180, and 0.209, respectively. The friction coefficients under current-free conditions are consistently higher than those under current-carrying conditions. In terms of wear rate, under a contact load of 25 N, the wear rates at 0 A, 40 A, and 80 A are 0.0069, 0.299, and 2.70 mm3/(N·m), respectively; under a contact load of 50 N, they are 0.010, 0.133, and 1.133 mm3/(N·m), respectively. No positive correlation is observed between contact load and the wear rate of the carbon-based friction pair, whereas increasing test current significantly exacerbates material damage. Regarding contact resistance, under a contact load of 25 N, the contact resistances at 40 A and 80 A are 34.7 Ω and 46.6 Ω, respectively; under a contact load of 50 N, they are 27.7 Ω and 37.9 Ω, respectively, indicating that lower contact loads correspond to higher contact resistances, and higher test currents also result in higher contact resistances. In summary, both increasing current and decreasing contact load aggravate the electrical damage to the contact pair materials, while increasing contact load exerts a significant inhibitory effect on electrical damage. This study provides theoretical insights into the damage mechanism and arc morphology evolution laws induced by electric arcs under contact wire irregularity conditions.

15 May 2026 in Materials
Verified
Journal Article
Open access
PDF file
WDWenhao Dai
Wenhao Dai
PCPengcheng Cheng
Pengcheng Cheng
毛毛毛福林 毛
毛福林 毛
LXLi Xiao
Li Xiao
DJDehui Ji
Dehui Ji
LMLinfeng Min
Linfeng Min
The pantograph–catenary system is a crucial component of rail transit vehicles, performing the vital function of electric energy transmission. During train operation, the current-carrying components continuously emit particulate matter into the surrounding environment due to friction, and these particulate emissions have a significant impact on human health. However, research on the correlation between the current-carrying friction of carbon contact strips and particulate matter emission characteristics is rarely reported. Based on a semi-enclosed pin-on-disc current-carrying friction and wear test rig, this paper investigates the effects of varying current intensity under different contact load conditions on the friction and wear performance of carbon/copper pairs, as well as the associated particulate matter emission behavior. It reveals the damage characteristics of carbon contact strips, the particulate matter emission characteristics, and the relationship between them under different service conditions. The results indicate that the wear mechanism and particulate matter emission behavior of carbon contact strips are jointly influenced by current magnitude and contact load. In the absence of current, increasing the load exacerbates the mechanical wear on the carbon friction pair surface, while elevating the emission concentration of particles of various sizes and stabilizing the particle size distribution. Under current-carrying conditions, a higher contact load effectively reduces the frequency of arc discharges between the friction pair. Meanwhile, the degree of arc erosion on the contact surface worsens with increasing current intensity. Arc discharges instantaneously lead to a sharp increase in particulate emissions, and the higher the discharge intensity or the greater the number of discharges, the higher the particulate concentration around the contact pair.