Akos Karoly Nagy

Dr. Akos Karoly Nagy


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2020 in medRxiv
Verified
Preprint
Open access
PDF file
LCLászló Márk Czumbel
László Márk Czumbel
SKSzabolcs Kiss
Szabolcs Kiss
NFNelli Farkas
Nelli Farkas
IMIván Mandel
Iván Mandel
AHAnita Emoke Hegyi
Anita Emoke Hegyi
GVGábor Varga
Gábor Varga
Objectives: Our aim was to conduct a meta-analysis on the reliability and consistency of SARS-CoV-2 viral RNA detection in saliva specimens. Methods: We reported our meta-analysis according to the Cochrane Handbook. We searched the Cochrane Library, Embase, Pubmed, Scopus, Web of Science and clinical trial registries for eligible studies published between 1 January and 25 April 2020. The number of positive tests and total number of conducted tests were collected as raw data. The proportion of positive tests in the pooled data were calculated by score confidence interval estimation with the Freeman-Tukey transformation. Heterogeneity was assessed using the I 2 measure and the χ 2 test. Results: The systematic search revealed 96 records after removal of duplicates. 26 records were included for qualitative analysis and 5 records for quantitative synthesis. We found 91% (95%CI = 80%-99%) sensitivity for saliva tests and 98% (95%CI 89%-100%) sensitivity for nasopharyngeal swab (NPS) tests in previously confirmed COVID-19 infected patients, with moderate heterogeneity among studies. Additionally, we identified 18 registered, ongoing clinical trials on saliva-based tests for detection of the virus. Conclusion: Saliva tests offer a promising alternative to NPS for COVID-19 diagnosis. However, further diagnostic accuracy studies are needed to improve their specificity and sensitivity.

18 August 2023 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
ATAnna Takács
Anna Takács
GMGyula Marada
Gyula Marada
Kinga TurzóKinga Turzó
Kinga Turzó
ANAkos Karoly Nagy
Akos Karoly Nagy
ONOrsolya Nemeth
Orsolya Nemeth
AMAttila Mühl
Attila Mühl
Background: The purpose of this in vitro study was to compare the accuracy of implant placement in model surgeries according to the design of the drills (straight drills or step drills) used to finalize the implant bed during pilot-guided static computer-assisted implant surgery (sCAIS). Methods: Model surgeries were carried out on resin models randomly assigned to three study groups. Virtual planning software (coDiagnostiX 10.6, Dental Wings, Montreal, Canada) was used to plan the implant positions. In Groups 1 and 2, pilot-guided sCAIS was performed. Straight drills were used in Group 1, and step drills were used in Group 2 to finalize the implant beds. In Group 3, fully guided sCAIS was performed using a universal fully guided kit (RealGUIDE Full Surgical Kit 3DIEMME, RealGUIDE, Cantù, Como, Italy). A total of 90 dental implants (Callus Pro, Callus Implant Solutions GmbH, Nuremberg, Germany) were placed (six implants per model, five models per study group). The primary outcome variables (angular deviation, coronal global deviation, and apical global deviation) were calculated for all implants based on the comparison of the preoperative surgical plan with the postoperative scans. Results: Group 2 (coronal global deviation, 0.78 ± 0.29 mm; apical global deviation, 1.02 ± 0.56 mm) showed significantly lower values of both global deviation variables than Group 1 (coronal global deviation, 0.95 ± 0.20 mm; apical global deviation, 1.42 ± 0.49 mm). However, there was no significant difference in angular deviation between Groups 1 and 2 (7.56 ± 2.92° and 6.44 ± 2.84°). Group 3 produced significantly lower values of all three primary outcome variables (angular deviation, 2.36 ± 0.90°; coronal global deviation, 0.59 ± 0.28 mm; apical global deviation, 0.90 ± 0.29 mm) than Group 1 and significantly lower angular deviation and coronal global deviation values than Group 2. Conclusions: The design of the drills used to finalize implant osteotomies during pilot-guided sCAIS influences dental implant placement accuracy. Using step drills instead of straight drills for final osteotomies decreases deviation from the surgical plan. The fully guided approach performed better than the pilot-guided sCAIS.

Verified
Journal Article
Open access
PDF file
RNRéka Rebeka Niklai
Réka Rebeka Niklai
PSPéter Szabó
Péter Szabó
JKJudit Kopniczky
Judit Kopniczky
TDTímea Dergez
Tímea Dergez
BKBela Kolarovszki
Bela Kolarovszki
DFDorottya Frank
Dorottya Frank
Metallic biomaterials are frequently exposed to chemically aggressive environments that may compromise surface integrity and corrosion resistance. Acidic media containing organic acids represent a relevant challenge for metallic systems, as they can destabilize passive oxide layers and promote surface degradation processes. The present in vitro study investigated acid-induced surface alterations in four commercially relevant orthodontic alloys—nickel–titanium (NiTi), copper–nickel–titanium (CuNiTi), titanium–molybdenum alloy (TMA), and stainless steel—as representative metallic biomaterials. Specimens were exposed to two commercially available acidic beverages with distinct pH conditions, followed by analysis of surface morphology, roughness, and elemental composition using atomic force microscopy (AFM), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDS). The results demonstrated pronounced alloy-dependent differences in degradation behavior. Stainless steel and TMAs exhibited significant increases in surface roughness and morphological alterations, whereas NiTi-based alloys showed comparatively stable surface characteristics. Elemental analysis revealed material-specific compositional variations, suggesting selective surface modification processes under acidic exposure. These differences can be attributed to variations in alloy composition, microstructure, and the stability of passive oxide layers, which collectively govern corrosion resistance in metallic systems. The findings provide insight into acid-induced degradation mechanisms in metallic biomaterials and highlight the importance of material-dependent corrosion behavior under chemically aggressive conditions. These observations may have implications for surface-mediated biological responses and long-term functional performance of metallic biomaterials.

Verified
Journal Article
Open access
PDF file
BKBela Kolarovszki
Bela Kolarovszki
ASAlexandra Steinerbrunner-Nagy
Alexandra Steinerbrunner-Nagy
DFDorottya Frank
Dorottya Frank
GDGabor Sandor Decsi
Gabor Sandor Decsi
AMAttila Mühl
Attila Mühl
Kinga TurzóKinga Turzó
Kinga Turzó
Background: Soft tissue stability around dental implant abutments is critical for maintaining a functional peri-implant seal. Yellow anodization is used to improve the aesthetic and surface characteristics of titanium abutments, yet its epithelial effects under more physiologically relevant 3D conditions remain insufficiently explored. Objective: To develop a 3D bioprinted in vitro peri-implant mucosa model and to compare epithelial cell responses on yellow anodized versus turned titanium abutment surfaces. Methods: Commercial Grade 5 (Ti6Al4V) titanium abutments were anodized and compared with turned controls. A collagen-based 3D bioprinted “collar-like” construct incorporating YD-38 epithelial cells was fabricated using a custom holder system to simulate peri-implant mucosal contact. Samples were cultured for 14 and 21 days. Cell distribution and morphology were assessed by optical microscopy and HE staining, while cytoskeletal organization was evaluated by TRITC-phalloidin/Hoechst staining and confocal microscopy. Quantitative fluorescence analysis was performed at 21 days. Results: Both surfaces supported epithelial coverage in the 3D environment. Anodized specimens showed more pronounced actin cytoskeletal organization and the presence of actin-rich, filamentous cellular extensions compared with turned controls. Quantitative image analysis demonstrated significantly higher TRITC-phalloidin signal intensity at 21 days on anodized samples (p < 0.001). Conclusions: Within the limitations of a 3D epithelial in vitro model using YD-38 cells, yellow anodization was associated with enhanced epithelial cytoskeletal organization compared with turned titanium. The presented 3D bioprinted platform may serve as a practical in vitro tool for screening abutment surface modifications relevant to peri-implant soft tissue integration.