Amirabbas Hadizade

Mr. Amirabbas Hadizade

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MZMostafa Zarghani
Mostafa Zarghani
SMSadegh Mohsenzade
Sadegh Mohsenzade
AHAmirabbas Hadizade
Amirabbas Hadizade
SKShahriyar Kaboli
Shahriyar Kaboli
This paper describes the development of an 18 kV, 30 kW power supply for a pulsed current load with the maximum current of 20 A and a di/dt equal to $100 \text{A}/\mu s$ . The achieved output ripple is less than 0.01%. In such a high level of precision, the most important issues are: 1) A considerable difference between the instantaneous and average output powers, as well as insufficient reaction speed of the converter to the fast load change. 2) Very low level of the voltage feedback and its sensitivity to the noise. The first issue necessitates a notable overdesign of the converter switches if the output voltage precision is dedicated to the converter. The second issue raises the problems relevant to observing the voltage ripple and providing it for the control loop. This paper proposes, a fast and high current linear regulator developed based on the load current feedforwarding. Using this approach, the fast regulator compensates the voltage change caused by a high level of instantaneous power. The main converter maintains the average power. Thus, there is not any need for the converter overdesigning. Furthermore, the problems relevant to the high voltage feedback and providing it for the control loop are removed. The voltage feedback is solely served to correct the current loop probable error. Hence the sensitivity of the control loop against the existing noise is minimized. Despite existing a 600nF capacitor as the output capacitor, the output voltage drop is less than 0.01 % in a wide range of the output current pulse up to $250 \mu s$ . The power supply is constructed and experimental results are provided to verify the mentioned specifications.

19 January 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
AHAmirabbas Hadizade
Amirabbas Hadizade
SKSeyed Hossein Kamali
Seyed Hossein Kamali
Mehrdad MoallemMehrdad Moallem
Mehrdad Moallem
In this paper, a smart time-domain technique is presented for detecting flaws in concrete structures using embedded piezoelectric transducers. The method relies on the time-of-flight of ultrasound waves generated and sensed by piezoelectric transducers which are embedded in a concrete structure before pouring the concrete. A damage index is introduced to quantify the likelihood of defects in the region between the two probes. The index is comprised of a normalization function that is independent of the strength of the captured signal and not sensitive with respect to the amount of coupling between the embedded sensors and the structure. A sliding mode extremum-seeking method is utilized for real time calculation of the damage index. The proposed health monitoring system was verified by experimental results. Comparisons are performed when using a conventional approach by a grid search method to demonstrate performance improvement of the proposed system.

17 July 2025 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
AHAmirabbas Hadizade
Amirabbas Hadizade
Mehrdad MoallemMehrdad Moallem
Mehrdad Moallem
MMMitchell Miller
Mitchell Miller
JWJason Wang
Jason Wang
The increasing penetration of inverter-based resources in modern power systems has led to a significant reduction in system inertia, creating challenges for maintaining grid frequency stability. To address these issues, a new ancillary service market, termed “Fast Frequency Response (FFR)”, has emerged. FFR mandates rapid power delivery from renewable energy sources,including wind power systems, immediately following contingency events to alleviate frequency drops in a few seconds. This paper presents a control method combining supercapacitor energy storage systems and wind turbine generators to enhance the FFR capabilities of wind power systems and mitigate the frequency drop. This approach ensures the readiness of supercapacitor energy storage systems to provide FFR services under diverse wind conditions. Additionally, a control scheme for the wind turbine generator is developed to optimize its participation in FFR across a range of wind speeds while maintaining a stable operation of the wind power system. The results demonstrate that, while preserving an equivalent investment cost to that of supercapacitor banks, wind power systems can significantly increase their FFR contributions. This improvement effectively addresses critical frequency stability challenges in low-inertia grids. Eventually, the proposed method is validated through real-time experiments on a hardware-in-the-loop (HIL) setup.


23 June 2026 in Energies
Verified
Journal Article
Open access
PDF file
AHAmirabbas Hadizade
Amirabbas Hadizade
SSSamira Asadi Shekafti
Samira Asadi Shekafti
Mehrdad MoallemMehrdad Moallem
Mehrdad Moallem
JWJason Wang
Jason Wang
The increasing penetration of inverter-based resources has significantly reduced system inertia, motivating the emergence of Fast Frequency Response (FFR) as a dedicated ancillary service. Existing methods for enabling wind power systems to deliver FFR universally treat the wind farm as a single equivalent turbine under uniform wind conditions, an assumption that is invalid in real large-scale wind farms where heterogeneous turbine types, rated capacities, inertia constants, and spatially non-uniform wind speed distributions render uniform allocation strategies suboptimal or operationally unsafe. This paper proposes a centralized wind farm-level FFR control framework that coordinates heterogeneous wind turbine generators (WTGs) and supercapacitor energy storage systems (SCESSs) through a prioritized two-tier dispatch hierarchy, in which SCESSs are assigned the highest dispatch priority and WTGs are engaged only when aggregate storage capacity is insufficient. A constrained optimization problem is formulated to allocate the individual FFR contribution of each WTG by minimizing the total kinetic energy extracted from the wind farm, while enforcing torque, electrical power, and rotor speed constraints for every unit with respect to turbine type, inertia constant, and prevailing wind condition. A coordinated rotor speed recovery strategy further eliminates secondary frequency disturbances during the post-FFR transition. The proposed framework is validated on a 138 MW heterogeneous wind farm simulation model comprising both Doubly-Fed Induction Generator and Permanent Magnet Synchronous Generator units interconnected to a modified IEEE 14-bus test system. The proposed method achieves a 38.85% improvement in frequency nadir relative to a baseline with no FFR provision, outperforming all investigated state-of-the-art approaches, while reducing total kinetic energy extraction from the wind turbine generators and eliminating secondary frequency disturbances during the post-FFR recovery phase.