We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz1/2 in x-axis, 25 fT/Hz1/2 in y-axis, 30 fT/Hz1/2 in z-axis is achieved with a miniature 4 × 4 × 4 mm 87Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).
Polarization holography has the unique capacity to record and retrieve the amplitude, phase, and polarization of light simultaneously in a polarization-sensitive recording material and has attracted widespread attention. Polarization holography is a noteworthy technology with potential applications in the fields of high-capacity data storage, polarization-controlled optical elements, and other related fields. The choice of its high-performance materials is particularly important. To further develop polarization holography applications and improve the quality of the information recorded (i.e., material sensitivity and resolution), a deeper understanding of such materials is needed. We present an overview of the polarization-sensitive materials, which introduced polarization holographic technology and the development of polarization holographic materials. The three main types of polarization holographic materials are described, including azopolymer materials, photopolymer material, and photorefractive polymer material. We examine the key contributions of each work and present many of the suggestions that have been made to improve the different polarization-sensitive photopolymer materials.
16 February 2023 in Sensors and Actuators A: Physical
We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z-axis remanence on xy-axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz in the x- and y- axis, and 230 fT Hz in the z-axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x-, y- and z-axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.
This study proposes an approach to generate a uniform flat-top beam with a liquid crystal spatial light modulator (LC-SLM) to optimize ultrasensitive inertial measurement. The random incomplete Gaussian beam is modulated into a flat-top beam by uploading a beam shaping optimization algorithm on an LC-SLM. Simulation results verify the effectiveness of the proposed method. The beam obtained from the experimental results with the 4f filter system optimization also conforms to the properties of the generated flat-top beam. Compared to existing beam shaping algorithms for simulation and experimental analysis, the beam shaping design based on the LC-SLM to optimize the ultrasensitive inertial measurement is realized. This method has also been verified to be effective in beam shaping in various beam situations. The application of this method in ultrahigh-sensitivity inertial measurement should prove significant.
In optical atomic magnetometers (AMs), the light-shift caused by the circularly polarized pumping beam have a significant impact on the response and is also one of the non-negligible sources of the noise. In this paper, we develop a novel method whereby utilizing the symmetry of the frequency response in an AM to measure and cancel the light-shift. Furthermore, we theoretically analyze and experimentally verify a rapid method of magnetic field compensation and the approach is convenient to measure and cancel of the light-shift. Moreover, the influence of intensity and frequency of the pumping beam is also investigated. The proposed method of in − situ measurement and cancellation of light-shift will be particularly profitable to other optical systems based on AMs.