Ivan Shchudlo

Dr. Ivan Shchudlo


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2021 in Biology
Verified
Journal Article
Open access
PDF file
Sergey TaskaevSergey Taskaev
Sergey Taskaev
EBEvgeny Berendeev
Evgeny Berendeev
MBMarina Bikchurina
Marina Bikchurina
TBTimofey Bykov
Timofey Bykov
DKDmitrii Kasatov
Dmitrii Kasatov
GVGleb Dmitrievich Verkhovod
Gleb Dmitrievich Verkhovod
A compact accelerator-based neutron source has been proposed and created at the Budker Institute of Nuclear Physics in Novosibirsk, Russia. An original design tandem accelerator is used to provide a proton beam. The proton beam energy can be varied within a range of 0.6–2.3 MeV, keeping a high-energy stability of 0.1%. The beam current can also be varied in a wide range (from 0.3 mA to 10 mA) with high current stability (0.4%). In the device, neutron flux is generated as a result of the 7Li(p,n)7Be threshold reaction. A beam-shaping assembly is applied to convert this flux into a beam of epithermal neutrons with characteristics suitable for BNCT. A lot of scientific research has been carried out at the facility, including the study of blistering and its effect on the neutron yield. The BNCT technique is being tested in in vitro and in vivo studies, and the methods of dosimetry are being developed. It is planned to certify the neutron source next year and conduct clinical trials on it. The neutron source served as a prototype for a facility created for a clinic in Xiamen (China).

12 December 2017 in Metals
Verified
Journal Article
Open access
PDF file
ABAlexander Badrutdinov
Alexander Badrutdinov
TBTimofey Bykov
Timofey Bykov
SGSergey A Gromilov
Sergey A Gromilov
YHYasuo Higashi
Yasuo Higashi
DKDmitrii Kasatov
Dmitrii Kasatov
Sergey TaskaevSergey Taskaev
Sergey Taskaev
A vacuum-insulated tandem accelerator was used to observe in situ blistering during 2-MeV proton irradiation of metallic samples to a fluence of up to 6.7 × 1020 cm−2. Samples consisting of copper of different purity, tantalum and tantalum-copper compounds were placed on the proton beam path and forced to cool. The surface state of the samples was observed using a charge-coupled device camera with a remote microscope. Thermistors, a pyrometer and an infrared camera were applied to measure the temperature of the samples during irradiation. After irradiation, the samples were analyzed on an X-ray diffractometer, laser and electron microscopes. The present study describes the experiment, presents the results obtained and notes their relevance and significance in the development of a lithium target for an accelerator-based neutron source, for use in boron neutron capture therapy of cancer.

24 August 2021 in Biology
Verified
Journal Article
Open access
PDF file
MBMarina Bikchurina
Marina Bikchurina
TBTimofey Bykov
Timofey Bykov
DKDmitrii Kasatov
Dmitrii Kasatov
IKIaroslav Kolesnikov
Iaroslav Kolesnikov
Aleksandr MakarovAleksandr Makarov
Aleksandr Makarov
Sergey TaskaevSergey Taskaev
Sergey Taskaev
A compact accelerator-based neutron source has been proposed and created at the Budker Institute of Nuclear Physics in Novosibirsk, Russia. An original design tandem accelerator is used to provide a proton beam. The neutron flux is generated as a result of the 7Li(p,n)7Be threshold reaction using the solid lithium target. A beam shaping assembly is applied to convert this flux into a beam of epithermal neutrons with characteristics suitable for BNCT. The BNCT technique is being tested in in vitro and in vivo studies, and dosimetry methods are being developed. Currently, the BNCT technique has entered into clinical practice in the world: after successful clinical trials, two clinics in Japan began treating patients, and four more BNCT clinics are ready to start operating. The neutron source proposed at the Budker Institute of Nuclear Physics served as a prototype for a facility created for a clinic in Xiamen (China). It is planned to equip the National Medical Research Center of Oncology (Moscow, Russia) and National Oncological Hadron Therapy Center (Pavia, Italy) with the same neutron sources. Due to the impending use of an accelerator neutron source for treating patients, the validation of the neutron yield of the 7Li(p,n)7Be reaction in lithium metal targets is required. The theoretical neutron yield has not been evaluated experimentally so far.

16 September 2021 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
Alexander ZaboronokAlexander Zaboronok
Alexander Zaboronok
Sergey TaskaevSergey Taskaev
Sergey Taskaev
OVOlga Volkova
Olga Volkova
LMLudmila Mechetina
Ludmila Mechetina
Anna KasatovaAnna Kasatova
Anna Kasatova
AMAkira Matsumura
Akira Matsumura
Boron neutron capture therapy (BNCT) is an anticancer modality realized through 10B accumulation in tumor cells, neutron irradiation of the tumor, and decay of boron atoms with the release of alpha-particles and lithium nuclei that damage tumor cell DNA. As high-LET particle release takes place inside tumor cells absorbed dose calculations are difficult, since no essential extracellular energy is emitted. We placed gold nanoparticles inside tumor cells saturated with boron to more accurately measure the absorbed dose. T98G cells accumulated ~50 nm gold nanoparticles (AuNPs, 50 µg gold/mL) and boron-phenylalanine (BPA, 10, 20, 40 µg boron-10/mL), and were irradiated with a neutron flux of 3 × 108 cm−2s−1. Gamma-rays (411 keV) emitted by AuNPs in the cells were measured by a spectrometer and the absorbed dose was calculated using the formula D = (k × N × n)/m, where D was the absorbed dose (GyE), k—depth-related irradiation coefficient, N—number of activated gold atoms, n—boron concentration (ppm), and m—the mass of gold (g). Cell survival curves were fit to the linear-quadratic (LQ) model. We found no influence from the presence of the AuNPs on BNCT efficiency. Our approach will lead to further development of combined boron and high-Z element-containing compounds, and to further adaptation of isotope scanning for BNCT dosimetry.

15 March 2023 in Molecules
Verified
Journal Article
Open access
PDF file
VRValeria Raskolupova
Valeria Raskolupova
MWMeiling Wang
Meiling Wang
MDMaya A. Dymova
Maya A. Dymova
GPGleb Petrov
Gleb Petrov
ISIvan Shchudlo
Ivan Shchudlo
TPTatyana Popova
Tatyana Popova
Combination therapy is becoming an increasingly important treatment strategy because multi-drugs can maximize therapeutic effect and overcome potential mechanisms of drug resistance. A new albumin-based theranostic containing gemcitabine closo-dodecaborate analogue has been developed for combining boron neutron capture therapy (BNCT) and chemotheraphy. An exo-heterocyclic amino group of gemcitabine was used to introduce closo-dodecaborate, and a 5′-hydroxy group was used to tether maleimide moiety through an acid-labile phosphamide linker. The N-trifluoroacylated homocysteine thiolactone was used to attach the gemcitabine analogue to human serum albumin (HSA) bearing Cy5 or Cy7 fluorescent dyes. The half-maximal inhibitory concentration (IC50) of the designed theranostic relative to T98G cells was 0.47 mM with the correlation coefficient R = 0.82. BNCT experiments resulted in a decrease in the viability of T98G cells, and the survival fraction was ≈ 0.4.

9 June 2026 in Cancers
Verified
Journal Article
Open access
PDF file
Sergey TaskaevSergey Taskaev
Sergey Taskaev
EBEvgeny Berendeev
Evgeny Berendeev
MBMarina Bikchurina
Marina Bikchurina
TBTimofey Bykov
Timofey Bykov
YCYulia Chesnokova
Yulia Chesnokova
GVGleb Dmitrievich Verkhovod
Gleb Dmitrievich Verkhovod
Purpose: To develop an accelerator neutron source suitable for boron neutron capture therapy—a new promising method for treating malignant tumors—and to develop dosimetry tools and methods. Methods: Research into the transport and acceleration of a beam of charged particles, development and manufacture of an accelerator neutron source, study of the radiation generated, and development and implementation of dosimetry tools and methods. Results: A facility called VITA has been created, which includes a tandem electrostatic accelerator of an original design for producing a 2.3 MeV 10 mA proton beam, a lithium target for generating neutrons in the 7Li(p,n)7Be reaction, and a beam shaping assembly for forming a therapeutic neutron beam. The facility at the institute is used for scientific research, the facility in Xiamen (China) is used for clinical trials, and the facility in Moscow (Russia) will soon be used for clinical trials. Also, new tools and methods for measuring the boron dose, γ-ray dose, and sum of the fast neutron dose and the nitrogen dose have been proposed and implemented. The conducted studies demonstrated the high efficiency of the VITA® facility, the first possibility of implementing prompt γ-ray spectroscopy for boron imaging, and the first possibility of implementing lithium neutron capture therapy, which has advantages over BNCT, and also presented the results of the development of new tools and methods for measuring the boron dose, γ-ray dose, and the sum of the fast neutron dose and the nitrogen dose. Conclusions: The authors strongly recommend using prompt γ-ray spectroscopy in treatment and developing lithium neutron capture therapy, including in combination with BNCT, and note the high efficiency, reliability and compactness of the VITA® facility.