This paper presents a centralized protection strategy for medium voltage dc microgrids. The proposed strategy consists of a communication-assisted fault detection method with a centralized protection coordinator and a fault isolation technique that provides an economic, fast, and selective protection by using the minimum number of dc circuit breakers. The proposed method is also supported by a backup protection that is activated if communication fails. This paper also introduces a centralized self-healing strategy that guarantees successful operation of zones that are separated from the main grid after the operation of the protection devices. Furthermore, to provide a more reliable protection, thresholds of the protection devices are adapted according to the operational modes of the microgrid and the status of distributed generators. The effectiveness of the proposed protection strategy is validated through real-time simulation studies based on the hardware in the loop approach.
1 November 2015 in Renewable and Sustainable Energy Reviews
A fault location method and a fault clearance strategy are presented in this paper for medium voltage dc (MVDC) distribution system. MVDC systems are applicable for connection between microgrids (MGs) and integration of renewable energy systems (RESs) to distribution systems. Due to the specifications of fault current in dc systems, it is difficult to coordinate the over current (O/C) relays based on the time inverse grading. Hence, in this paper, a communication link between O/C relays is used to diagnose the fault location. On the other hand, the fault clearance is done by the operation of dc circuit breakers (DCCB) and isolator switches. In this protection strategy, O/C relays detect the faulty part using communication links and after the fault extinguishing by DCCBs, the dc switches isolate the faulty part. Finally, the sound parts of the system re-energize when DCCB are re-closed. Moreover, data transmission by communication links is based on the standard messages of IEC61850 protocol.
This paper describes the application of tuned power harmonic filters (PHFs) to a three phase shunt active power filter (APF) for the harmonic minimization created by a nonlinear load. This work is performed in order to show implementation of optimized harmonic power filters to a shunt active power filter can reduce total harmonic distortion (THD) without creating new system resonance. Steady state and transient performance of proposed hybrid active power filter (HAPF) were studied through computer simulation results. This results show the proposed hybrid active power filter eliminates THD less than 1 percent in two cycles.
This paper presents a Network Clustering (NC) method for active distribution networks (ADNs). Following the outage of a section of an ADN, the method identifies and forms an optimum cluster of microgrids within the section. The optimum cluster is determined from a set of candidate microgrid clusters by estimating the following metrics: total power loss, voltage deviations and minimum load shedding. To compute these metrics, equivalent circuits of the clusters are estimated using measured data provided by Phasor Measurement Units (PMUs). Hence, the proposed NC method determines the optimum microgrid cluster without requiring information about the network’s topology and its components. The proposed method is tested by simulating a study network in a real-time simulator coupled to physical PMUs and a prototype algorithm implementation, also executing in real-time.