Catalin Gavriluta

Catalin Gavriluta

Auto-generated profile, based on publicly available information

Catalin Gavriluta

AIT Austrian Institute of Technology GmbH, Vienna, Austria

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2016 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MMMehdi Monadi
Mehdi Monadi
CGCatalin Gavriluta
Catalin Gavriluta
Alvaro LunaAlvaro Luna
Alvaro Luna
JCJose Ignacio Candela
Jose Ignacio Candela
PRPedro Rodriguez
Pedro Rodriguez
This paper presents a centralized protection strategy for medium voltage dc microgrids. The proposed strategy consists of a communication-assisted fault detection method with a centralized protection coordinator and a fault isolation technique that provides an economic, fast, and selective protection by using the minimum number of dc circuit breakers. The proposed method is also supported by a backup protection that is activated if communication fails. This paper also introduces a centralized self-healing strategy that guarantees successful operation of zones that are separated from the main grid after the operation of the protection devices. Furthermore, to provide a more reliable protection, thresholds of the protection devices are adapted according to the operational modes of the microgrid and the status of distributed generators. The effectiveness of the proposed protection strategy is validated through real-time simulation studies based on the hardware in the loop approach.

12 November 2014 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
CGCatalin Gavriluta
Catalin Gavriluta
ICIgnacio Candela
Ignacio Candela
Alvaro LunaAlvaro Luna
Alvaro Luna
AGAntonio Gomez-Exposito
Antonio Gomez-Exposito
Pedro RodriguezPedro Rodriguez
Pedro Rodriguez
This paper proposes a hierarchical control architecture designed for an arbitrary high voltage multiterminal dc (MTDC) network. In the proposed architecture, the primary control of the MTDC system is decentralized and implemented using a generalized droop strategy. Design criteria for dimensioning the primary control parameters, including voltage limits, are offered by analyzing the transients appearing in the system. The proposed secondary control is centralized and regulates the operating point (OP) of the network so that optimal power flow (OPF) is achieved. Compared to previous works, this paper further elaborates, both analytically and through simulations, on the coordination between the primary and secondary control layers. This includes how local primary controllers have to be driven by the centralized controller in order to ensure a smooth transition to the optimal OP.

4 April 2014 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
CGCatalin Gavriluta
Catalin Gavriluta
JCJ. Ignacio Candela
J. Ignacio Candela
CCCostantino Citro
Costantino Citro
JRJoan Rocabert
Joan Rocabert
ALAlvaro Luna
Alvaro Luna
Pedro RodriguezPedro Rodriguez
Pedro Rodriguez
Multiterminal dc networks are drawing a lot of interest lately in applications related to distributed generation, particularly in those that also integrate energy storage (ES). A few approaches for controlling the operation of such systems have been proposed in the literature; however, the existing structures can be significantly enhanced. This paper proposes an improved primary control layer, based on custom droop characteristics obtained by combining concepts of droop and dc-bus signaling control. This approach is designed to be generic and takes into account the various operating states of the network. Five operating bands, similar to the operating states of the ac grids, as well as various droop characteristics for different elements connected to the dc network, are defined. For the ES, the state of charge is taken into account at the primary control level and included in the droop characteristic, creating a two-variable droop surface. The proposed control strategy is validated through simulation and experimental results obtained from a case study that involves a micro dc network composed of a photovoltaic generator, a lead-acid battery, and a connection point to the ac grid.

21 January 2015 in IEEE Transactions on Power Delivery
Verified
Journal Article
Open access
CGCatalin Gavriluta
Catalin Gavriluta
JCJ. Ignacio Candela
J. Ignacio Candela
JRJoan Rocabert
Joan Rocabert
Alvaro LunaAlvaro Luna
Alvaro Luna
Pedro RodriguezPedro Rodriguez
Pedro Rodriguez
Multiterminal dc (MTDC) systems are drawing a lot of interest lately in applications related to distributed generation, especially in those that integrate wind or photovoltaic (PV) generation with energy storage (ES). Several approaches for controlling the operation of such systems have been proposed in the literature; however, the existing structures are mainly application specific and, thus, can be still improved in order to provide a more generic approach. This paper proposes an improved primary control layer for an MTDC system. The concept is based on the combination of a droop control method and dc bus signaling in order to provide a more generic and flexible solution. In this paper, different droop characteristics are proposed for the various elements connected to the dc bus. All of them are specifically tailored around five operation bands, which depend on the dc bus voltage level. Special attention is paid to the integration of ES: the state of charge (SoC) is considered at the primary control level, yielding a surface characteristic that depends on the SoC and the dc bus voltage. The scaling of the system has been analyzed together with the proposed control strategy and the overall operation has been validated through simulations by considering a 100 kW PV system with energy storage. Experimental results were obtained on a scaled laboratory prototype rated at 10 kW.

29 September 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TNTung-Lam Nguyen
Tung-Lam Nguyen
Yu WangYu Wang
Yu Wang
QTQuoc-Tuan Tran
Quoc-Tuan Tran
RCRaphael Caire
Raphael Caire
Yan XuYan Xu
Yan Xu
CGCatalin Gavriluta
Catalin Gavriluta
In this article, a distributed hierarchical control framework with coordinated secondary and tertiary levels is proposed for islanded microgrids (MGs). The structure and functionality of each agent are formulated to process simultaneously the secondary control and TC in a peer-to-peer communication network. First, the distributed secondary control is proposed for restoring system frequency/voltage while providing power sharing considering droop coefficients and upper level power dispatch orders. Then the distributed TC minimizes the network power loss in the islanded MG by using alternating direction method of multipliers (ADMM) algorithm. The multiagent system is designed to cover both control levels for cyber–physical implementations. A laboratory cyber–physical MG platform has been built to validate the proposed control framework in real-time and hardware-in-the-loop conditions. A six-bus three-DG MG is implemented on the platform and the experimental results validate the effectiveness of the proposed method.

1 May 2015 in Electric Power Systems Research
Verified
Journal Article
Open access
CGCatalin Gavriluta
Catalin Gavriluta
ICIgnacio Candela
Ignacio Candela
CCCostantino Citro
Costantino Citro
Alvaro LunaAlvaro Luna
Alvaro Luna
Pedro RodriguezPedro Rodriguez
Pedro Rodriguez
Multi-terminal dc networks based on voltage source converters (VSC) are the latest trend in dc-systems; the interest in the area is being fueled by the increased feasibility of these systems for the large scale integration of remote offshore wind resources. Despite the active research effort in the field, at the moment, issues related to the operation and control of these networks, as well as sizing, are still uncertain. This paper intends to make a contribution in this field by analyzing the sizing of droop control for VSC together with the output capacitors. Analytical formulas are developed for estimating the voltage peaks during transients, and then it is shown how these values can be used to dimension the dc-bus capacitor of each VSC. Further on, an improved droop control strategy that attenuates the voltage oscillations during transients is proposed. The proposed methods are validated on the dc-grid benchmark proposed by the CIGRE B4 working group. Starting from the structure of the network and the power rating of the converters at each terminal, the output capacitors and the primary control layer are designed together in order to ensure acceptable voltage transients.(C) 2014 Elsevier B.V. All rights reserved.Peer ReviewedPostprint (author’s final draft