Mojtaba Moghimi

Dr. Mojtaba Moghimi

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Energy and Buildings
Verified
Journal Article
Closed access
DLDomagoj Leskarac
Domagoj Leskarac
MMMojtaba Moghimi
Mojtaba Moghimi
JLJiannan Liu
Jiannan Liu
WWWayne Water
Wayne Water
Junwei LuJunwei Lu
Junwei Lu
SSSascha Stegen
Sascha Stegen

2 August 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
AAAli Alizadeh
Ali Alizadeh
AFAlireza Fereidunian
Alireza Fereidunian
MMMojtaba Moghimi
Mojtaba Moghimi
HLHamid Lesani
Hamid Lesani
Reliability-centered maintenance (RCM) as a subset of the reliability assessment problems, is a powerful tool for enhancing reliability, and subsequently achieving the customers’ higher satisfaction. However, deterministic RCM models could scarcely guarantee global optimality and feasibility of their solutions with real-world uncertain failure rates. In this paper, a robust model is proposed to consider the impact of failure rate uncertainty in the RCM scheduling problem, followed by a two-stage robust model development. The two-stage robust model is solved using Benders decomposition (BD) and outer approximation (OA) algorithms. The proposed model and solution method are applied to both educational RBTS2 system and real-size Finnish Distribution System, followed by demonstration of a higher financial and reliability performance, compared to that of the deterministic model. Sensitivities of the costs, available budget, uncertainty interval and computational time are analyzed and discussed, to conclude the paper.

25 October 2018 in IEEE Systems Journal
Verified
Journal Article
Closed access
PJPouya Jamborsalamati
Pouya Jamborsalamati
EFEdstan Fernandez
Edstan Fernandez
MMMojtaba Moghimi
Mojtaba Moghimi
Jahangir HossainJahangir Hossain
Jahangir Hossain
AHAlireza Heidari
Alireza Heidari
Junwei LuJunwei Lu
Junwei Lu
This paper proposes an autonomous resource allocation system (RAS) for smart neighborhood areas in presence of distributed energy resources and storage systems, with the purpose of grid demand reduction (GDR). Different from the past research on RAS, most of which are not broken down into resource allocation of individual appliances, do not address practical implementation of RAS with communication systems, and do not consider realistic case scenarios with network latency and communication link failure, this paper presents an improved appliance-level RAS developed in four operational modes with a designed bidding mechanism to exchange energy among neighborhood members through a common storage facility, a hierarchical cloud-based two-layered communication architecture founded on message queuing telemetry transport protocol to implement local and global messaging required for the proposed RAS, and realistic case scenarios by considering data from a real-world residential area and utilizing a virtual wide area network emulator to emulate characteristics of a real network in order to investigate the effects of network latency or communication link failure on the implemented RAS. From the results of diverse scenarios, it could be observed that the proposed system performs effectively to achieve GDR, even if the communication system fails partially in the smart community under test.

1 November 2015
Verified
Conference Paper
Closed access
MMMojtaba Moghimi
Mojtaba Moghimi
CBChristopher Bennett
Christopher Bennett
DLDomagoj Leskarac
Domagoj Leskarac
SSSascha Stegen
Sascha Stegen
Junwei LuJunwei Lu
Junwei Lu
In this paper, the communication architecture of an experimental MicroGrid is designed and implemented. Modbus TCP/IP is used as the communication protocol in the MicroGrid to receive data and send commands to different components within the MicroGrid. HTTP TCP/IP is applied as a back-up protocol in case of no availability of Modbus TCP/IP, and also serves as the protocol platform for displaying meaningful data regarding the MicroGrid. Implementation of data acquisition in a database for control and forecasting purposes and data exhibition in a website for monitoring purposes are also presented in this paper. A design for a future implementation of an AC/DC Hybrid Multi-MicroGrid with an advanced communication architecture is proposed as the next phase of the experimental MicroGrid.

9 November 2018 in Energies
Verified
Journal Article
Open access
PDF file
MMMojtaba Moghimi
Mojtaba Moghimi
JLJiannan Liu
Jiannan Liu
PJPouya Jamborsalamati
Pouya Jamborsalamati
FRFida Rafi
Fida Rafi
MRMd Shihanur Rahman
Md Shihanur Rahman
Junwei LuJunwei Lu
Junwei Lu
In this paper, an Internet of Things (IoT) platform is proposed for Multi-Microgrid (MMG) system to improve unbalance compensation functionality employing three-phase four-leg (3P-4L) voltage source inverters (VSIs). The two level communication system connects the MMG system, implemented in Power System Computer Aided Design (PSCAD), to the cloud server. The local communication level utilizes Modbus Transmission Control Protocol/Internet Protocol (TCP/IP) and Message Queuing Telemetry Transport (MQTT) is used as the protocol for global communication level. A communication operation algorithm is developed to manage the communication operation under various communication failure scenarios. To test the communication system, it is implemented on an experimental testbed to investigate its functionality for MMG neutral current compensation (NCC). To compensate the neutral current in MMG, a dynamic NCC algorithm is proposed, which enables the MGs to further improve the NCC by sharing their data using the IoT platform. The performance of the control and communication system using dynamic NCC is compared with the fixed capacity NCC for unbalance compensation under different communication failure conditions. The impact of the communication system performance on the NCC sharing is the focus of this research. The results show that the proposed system provides better neutral current compensation and phase balancing in case of MMG operation by sharing the data effectively even if the communication system is failing partially.

1 June 2018
Verified
Conference Paper
Closed access
MMMojtaba Moghimi
Mojtaba Moghimi
PJPouya Jamborsalamati
Pouya Jamborsalamati
Jahangir HossainJahangir Hossain
Jahangir Hossain
SSSascha Stegen
Sascha Stegen
Junwei LuJunwei Lu
Junwei Lu
This paper proposes the communication platform for Multi-Microgrid (MMG) Energy Management System (EMS) using combination of communication protocols in a hierarchical architecture. There is an Internet of Things (IoT) gateway designed in the proposed platform, which aims to connect multiple Microgrids to each other. Through the designed communication platform, bi-directional data exchange among the MGs for the optimal operation of the M Gs could be achieved. Due to the high number of devices required to communicate in MMG optimization problems, a cloud-based server, which enables extensive data sharing and analysis of the collected data, is employed in this work. Modbus protocol is used for the local communication level, i.e. communications between the devices within an individual MG and the MG Central Controller (MGCC). Message Queue Telemetry Transport (MQTT) protocol is adopted for communications between MGCCs and cloud. Furthermore, HTTP requests are the main communication method for interactions with the cloud channels. A virtual wide Area Network emulator (WANem machine) is adopted to emulate network latency in the system. In case of high latency in the network, MGCC takes action on delivering the optimization results for its Microgrid. The efficiency of the implemented platform for the EMS performance of the MMG is shown by comparing the total cost related to the MMG operation in centralized and distributed modes.