Loads in low voltage (LV) residential areas are mainly single-phase types which are supplied from a delta/wye connected distribution transformer (DT) with a grounded neutral conductor creating a three-phase (3P) four-wire (4W) distribution system. The unbalanced single-phase load distributions in traditional 3P-4W LV networks cause significant neutral currents which can result in the overloading of the neutral conductor and electrical safety concerns for customers. In this paper, the dependency of the load generated neutral current on the distribution line variable zero sequence R/X ratios is developed, and a new decentralized robust active neutral compensation method is proposed using a multi-functional transformer-less three phase (3P) four leg (4L) photovoltaic (PV) smart voltage source inverter (SVSI). System stability is verified from the bode analysis and the improved neutral compensation is evaluated from the circuitry model analysis. Actual single-phase customer loads with real sun irradiance and temperature profiles are used with an urban 3P-4W LV network model from Australia and implemented in simulation using the PSCAD/EMTDC software to verify the efficacy of the proposed controller in real world distribution networks. Different transient faults analyses and point of common coupling dynamic voltage regulation are also performed and faster fault recovery, better neutral compensation, and optimized voltage profile are achieved from the designed PV-SVSI.
20 July 2018 in IEEE Transactions on Industrial Electronics
The presence of neutral current is quite common in three-phase four-wire distribution systems due to unequal distribution of linear and nonlinear single-phase loads. However, high neutral current can overload the neutral conductor, which can cause electrical safety concerns at the installation terminals. Among neutral current compensators, the three-phase four-leg voltage source inverter (VSI) provides better control flexibility and efficient performance than the passive compensators, but requires a higher VSI capacity. To provide a solution to the aforementioned problem, this paper presents a novel control method to utilize the available capacity of a three-phase four-leg (3P-4L) VSI after active and reactive power regulation to enhance the neutral current compensation. A smart (S) VSI is designed to operate with renewable energy sources and minimize the neutral current. Case studies are conducted using commercial building actual load data in PSCAD/EMTDC software environment. The system with the proposed control method can provide improvement in the neutral current compensation, phase balancing and unbalance factor compared to a fixed capacity 3P-4L SVSI. Experimental results using a TMS320F28335 DSP microcontroller and modified Semiteach 3P-4L inverter are presented to verify the robustness of the controllers and enhancement in the neutral current compensation using the proposed capacity control method.
In this paper, an Internet of Things (IoT) platform is proposed for Multi-Microgrid (MMG) system to improve unbalance compensation functionality employing three-phase four-leg (3P-4L) voltage source inverters (VSIs). The two level communication system connects the MMG system, implemented in Power System Computer Aided Design (PSCAD), to the cloud server. The local communication level utilizes Modbus Transmission Control Protocol/Internet Protocol (TCP/IP) and Message Queuing Telemetry Transport (MQTT) is used as the protocol for global communication level. A communication operation algorithm is developed to manage the communication operation under various communication failure scenarios. To test the communication system, it is implemented on an experimental testbed to investigate its functionality for MMG neutral current compensation (NCC). To compensate the neutral current in MMG, a dynamic NCC algorithm is proposed, which enables the MGs to further improve the NCC by sharing their data using the IoT platform. The performance of the control and communication system using dynamic NCC is compared with the fixed capacity NCC for unbalance compensation under different communication failure conditions. The impact of the communication system performance on the NCC sharing is the focus of this research. The results show that the proposed system provides better neutral current compensation and phase balancing in case of MMG operation by sharing the data effectively even if the communication system is failing partially.