Inmaculada Fernandez

Dr. Inmaculada Fernandez

Department of Electrical and Energy Engineering, University of Cantabria, Santander, Cantabria, 39005, Spain
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2013 in Electric Power Systems Research
Verified
Journal Article
Closed access
Inmaculada FernandezInmaculada Fernandez
Inmaculada Fernandez
COCristian Olmo
Cristian Olmo
FDFernando Delgado
Fernando Delgado
CRCarlos J Renedo
Carlos J Renedo
SPSeveriano Pérez
Severiano Pérez

1 May 2012 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
Inmaculada FernandezInmaculada Fernandez
Inmaculada Fernandez
CRCarlos J Renedo
Carlos J Renedo
SPSeveriano F. Pérez
Severiano F. Pérez
COCristian Olmo
Cristian Olmo
Mario MananaMario Manana
Mario Manana

1 July 2016 in Applied Thermal Engineering
Verified
Journal Article
Open access
Inmaculada FernandezInmaculada Fernandez
Inmaculada Fernandez
FDFernando Delgado
Fernando Delgado
FOFélix Ortiz
Félix Ortiz
COCristian Olmo
Cristian Olmo
CFCristina Fernández
Cristina Fernández
ASAgustín Santisteban
Agustín Santisteban
Kraft paper in combination with dielectric oil is the most common as insulation system used in power transformers. The most used oil in power transformers is mineral oil. However, dielectric oils based on natural esters possess some advantages in comparison with mineral oil such as higher biodegradability, fire safety and availability. Therefore, they might be the most ideal substitute for mineral oil. The introduction of a new material requires the evaluation of its degradation rate because this determines transformers’ life span. In order to assess the performance of new insulating systems based on vegetable oils, simulations to obtain the hot-spot temperatures in power transformers using vegetable oils and controlled laboratory experiments of ageing were carried out. The reason is that hot spot temperature inside windings of the oil-immersed power transformers is one of the main manifestations of the thermal stress which leads to aging of insulation systems.The research leading to these results has received funding from multiple sources during years but we would specifically like to acknowledge the support received in the later stages from the Spanish Plan Estatal de I+D under the grant agreement DPI2013- 43897-P

1 January 2009 in Journal of Cleaner Production
Verified
Journal Article
Closed access
Inmaculada FernandezInmaculada Fernandez
Inmaculada Fernandez
CRCarmen Ruiz-Puente
Carmen Ruiz-Puente

27 November 2017 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Open access
ASA. Santisteban
A. Santisteban
FDFernando Delgado
Fernando Delgado
COCristian Olmo
Cristian Olmo
Inmaculada FernandezInmaculada Fernandez
Inmaculada Fernandez
CRCarlos J Renedo
Carlos J Renedo
FOF. Ortiz
F. Ortiz
The assessment of two vegetal oils as coolant in Low Voltage Winding of a power transformer with zigzag cooling have been analyzed. These dielectric fluids cooling performance has been compared with a typical mineral oil. To make the study, a 2D-axisymmetrical model of a power transformer has been developed to perform a numerical analysis using a Finite Element Method based software, COMSOL Multiphysics ® . Some values are obtained in order to establish the comparison, such as hot-spot temperature or hot-spot factor. Moreover, the influence of the increase of the number of passes of the cooling circuit on the hot-spot temperature has been evaluated for all liquids and compared with the initial design. Results obtained in this work show that the hot-spot temperature is lower for the vegetal oils in the initial design. Furthermore, an increase in the number of passes affect more positively to the mineral oil since similar values of the hot-spot temperature for all liquids are obtained. Values of the hot-spot factor indicates that higher number of passes leads to lower efficient cooling circuits owing to the increase of the pressure drop although the hot-spot temperature decreases.

6 April 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Inmaculada FernandezInmaculada Fernandez
Inmaculada Fernandez
RVRafael Valiente
Rafael Valiente
OFOrtiz Feranandez
Ortiz Feranandez
CRCarlos J Renedo
Carlos J Renedo
COCristian Olmo
Cristian Olmo
Over the last few decades the insulating performance of transformer oils has been broadly studied under the point of view of nanotechnology, which tries to improve the insulating and heat dissipation performance of transformer oils by suspending nanoparticles. Many authors have analyzed the thermal and dielectric behavior of vegetable oil based-nanofluids, however, very few works have studied the evolution of these liquids during thermal aging and their stability. In this paper has been evaluated the performance of aged vegetable oil based-nanofluids, which have been subjected to accelerated thermal aging at 150 °C. Nanoparticles of TiO2 and ZnO have been dispersed in a commercial natural ester. Breakdown voltage, resistivity, dissipation factor and acidity of nanofluid samples have been measured according to standard methods, as well as stability. Moreover, it has been analyzed the degradation of Kraft paper through the degree of polymerization (DP). The results have showed that although nanoparticles improve breakdown voltage, they increase the ageing of insulation liquids and dielectric paper.