A total of 66 smart implants were included. As a measure of bony stability, the relative elastic compliance of the osteosynthesis was determined from the gradient between the applied external load and the measured implant load over the entire healing process. The healing process of non-unions of the femur with a smart implant was tracked by telemetric measurements over a timespan of up to 10 years. The measurements of the longest healing process show a very slow but constant decrease in force transmission over the implant, radiological findings over 10 years show corresponding consolidation until bony healing. The use of a telemetrically instrumented bone plate, a so-called smart implant, to monitor the healing process is a successful procedure to support the clinician in his decision to take further surgical measures or to wait until healing occurs.
Besides the need for biomaterial surface modification to improve cellular attachment, laser-structuring is favorable for designing a new surface topography for external bone fixator pins or implants. The principle of this study was to observe how bioinspired (deer antler) laser-induced nano–microstructures influenced the adhesion and growth of skin cells. The goal was to create pins that allow the skin to attach to the biomaterial surface in a bacteria-proof manner. Therefore, typical fixator metals, steel, and titanium alloy were structured using ultrashort laser pulses, which resulted in periodical nano- and microstructures. Surface characteristics were investigated using a laser scanning microscope and static water contact angle measurements. In vitro studies with human HaCaT keratinocytes focused on cell adhesion, morphology, actin formation, and growth within 7 days. The study showed that surface functionalization influenced cell attachment, spreading, and proliferation. Micro-dimple clusters on polished bulk metals (DC20) will not hinder viability. Still, they will not promote the initial adhesion and spreading of HaCaTs. In contrast, additional nanostructuring with laser-induced periodic surface structures (LIPSS) promotes cell behavior. DC20 + LIPSS induced enhanced cell attachment with well-spread cell morphology. Thus, the bioinspired structures exhibited a benefit in initial cell adhesion. Laser surface functionalization opens up new possibilities for structuring, and is relevant to developing bioactive implants in regenerative medicine.
The impedance profile of the human PC-3 and DU 145 prostate cancer cells were recorded and compared using Electrical Impedance Spectroscopy. Cells were measured in a special chamber using a four terminal setup to avoid parasitic effects of electrode polarization in low frequencies. Our results show that the two cancer cell lines are readily distinguishable by their impedance spectrum. As PC-3 cells have been shown to be spontaneously metastatic in previous xenograft experiments while DU 145 cells were non-metastatic, Electrical Impedance Spectroscopy has the potential to be developed into a simple diagnostic tool to distinguish metastatic from non-metastatic cells.
(1) Aim: This study aims to assess the repeatability and accuracy of a 9-axis IMU-based glove and an IR camera system, in order to determine their potential to replace traditional goniometry. (2) Background: Traditional methods for assessing hand function, such as goniometry, are time-consuming and limited by subjectivity, inter-rater variability and external factors that compromise accuracy and reliability. Recent advancements in motion capture technology and sensor-based devices offer potential improvements in efficiency and accuracy for hand rehabilitation assessment; (3) Methods: To evaluate the repeatability of an IMU-based glove and an IR camera, measurements were taken using a silicone hand model under controlled conditions, while accuracy assessments involved a volunteer without movement constraints. Bland–Altman plots were employed for visual comparison and accuracy evaluation; (4) Results: The Nuada glove exhibited high repeatability, with standard deviations below two degrees across all joints, surpassing the goniometer’s accuracy threshold of five degrees. The UltraLeap system demonstrated comparable repeatability, with deviations consistently under 3.5 degrees. Accuracy assessments revealed limitations: over 50% of the Nuada glove’s measurements and over 80% of UltraLeap’s measurements deviated by more than five degrees compared to the goniometer. However, the Nuada glove and UltraLeap system were more consistent with each other than with the goniometer, suggesting limitations in the goniometer’s reliability for modern mobility assessment; (5) Conclusions: Both devices exhibited excellent repeatability, highlighting their strong potential for clinical application. However, their accuracy compared to the goniometer requires further refinement. These findings suggest that these technologies could enhance traditional assessment methods, offering more efficient and accurate solutions for evaluating hand mobility in clinical settings.