Robert Wendlandt

Dr. Robert Wendlandt

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in Journal of Hospital Infection
Verified
Journal Article
Closed access
RWRobert Wendlandt
Robert Wendlandt
MTM. Thomas
M. Thomas
BKB. Kienast
B. Kienast
ASArndt Peter Schulz
Arndt Peter Schulz

23 August 2023 in Injury
Verified
Journal Article
Open access
NHNico Hinz
Nico Hinz
KSKatrin Stacenko
Katrin Stacenko
CLCHRISTIAN LUTZ
CHRISTIAN LUTZ
ASArndt Peter Schulz
Arndt Peter Schulz
RWRobert Wendlandt
Robert Wendlandt
Dynamization of proximal femoral nailing by removal of distal interlocking is one of the recommended treatment options for nonunions of femur fractures. However, in certain inter-/subtrochanteric fractures, gliding of the nail along the femoral shaft is blocked by lateral femoral cortical support of the lag screw. For these cases, Biber et al. proposed lateral cortical notching (LCN), in which the supporting lateral bone is removed. This study investigates the biomechanical effect of LCN on gliding of proximal femoral nailing and stress distribution at the bone/implant interface. In this finite element analysis a three-dimensional model of an unstable intertrochanteric fracture with proximal femoral nailing without distal interlocking was simulated using the FebioStudio software suite. To simulate LCN, the lag screw hole was lengthened to 15.34 mm at the lateral cortex. Displacement of the nail along the femoral shaft axis and von Mises stress distribution were compared between LCN model and standard implantation model. Displacement of the nail along the femoral shaft axis was higher in the LCN model than in the standard implantation model (0.48 mm vs. 0.07 mm). Highest von Mises stresses of 176-178 MPa at the implant and of 52-81 MPa at the proximal femur were detected. Maximum von Mises stresses of the implant were comparable at all sides, except for a reduced von Mises stress at the lateral inferior side in the LCN model (80 vs. 102 MPa). At the inferior lateral screw hole and the anterior/posterior lateral screw hole maximum von Mises stress was reduced in the LCN model (2 vs. 49 MPa and 52 vs. 81 MPa), whereas the maximum von Mises stress at the inferior medial screw hole was higher in the LCN model than in the standard implantation model (53 vs. 27 MPa). Lateral cortical notching facilitates gliding of a distally dynamized proximal femoral nail along the femoral shaft axis in intertrochanteric fractures. Additionally, the lack of lateral cortical bone support at the lag screw reduces von Mises stress at the bone/implant interface and thus could lower the risk for implant breakage and peri‑implant fractures.

25 August 2022 in International Journal of Occupational Safety and Ergonomics
Verified
Journal Article
Closed access
JWJonathan Witte
Jonathan Witte
ACAlexandra Corominas
Alexandra Corominas
BEBenjamin Ernst
Benjamin Ernst
UKUwe Kaulbars
Uwe Kaulbars
RWRobert Wendlandt
Robert Wendlandt
EOElke Ochsmann
Elke Ochsmann
Objectives. Exposure to hand-transmitted shocks is a widespread phenomenon in the workplace. Separate risk assessments for shocks do not exist in current international hand–arm vibration regulations, leading to potential underestimation of associated health risks. Methods. In a pilot study approach, eight healthy males were exposed to sets of 3 × 5 min of repetitive shocks and 1 × 5 min of random vibration, controlled at a weighted vibration total value of 10 m/s2. Baseline and post-exposure measurements of vibration perception thresholds, finger skin temperature, maximal grip/pinch force and the Purdue pegboard test were conducted. Muscle activity was monitored continuously by surface electromyography. Results. Shock exposures evoked a temporary increase of vibration perception thresholds with high examination frequencies. A decrease of skin temperature was hinted for shocks of 1 and 20 s–1. Electromyographical findings indicated an additional load on two forearm muscles during shock transmission. Maximum grip force and manual dexterity were not affected, and pinch force only partially reduced after the exposures. Conclusion. Physiological effects from shock exposure conform to those described for hand–arm vibration exposure in principle, although some divergence can be hypothesized. Randomized designs are required to conclusively assess the need of occupational health concepts specifically for hand-transmitted shocks.

Verified
Journal Article
Open access
PDF file
Susanne StählkeSusanne Stählke
Susanne Stählke
BBBarth Barth
Barth Barth
MMMuench Muench
Muench Muench
JSJoerg Schroeter
Joerg Schroeter
RWRobert Wendlandt
Robert Wendlandt
ASArndt Peter Schulz
Arndt Peter Schulz
Besides the need for biomaterial surface modification to improve cellular attachment, laser-structuring is favorable for designing a new surface topography for external bone fixator pins or implants. The principle of this study was to observe how bioinspired (deer antler) laser-induced nano–microstructures influenced the adhesion and growth of skin cells. The goal was to create pins that allow the skin to attach to the biomaterial surface in a bacteria-proof manner. Therefore, typical fixator metals, steel, and titanium alloy were structured using ultrashort laser pulses, which resulted in periodical nano- and microstructures. Surface characteristics were investigated using a laser scanning microscope and static water contact angle measurements. In vitro studies with human HaCaT keratinocytes focused on cell adhesion, morphology, actin formation, and growth within 7 days. The study showed that surface functionalization influenced cell attachment, spreading, and proliferation. Micro-dimple clusters on polished bulk metals (DC20) will not hinder viability. Still, they will not promote the initial adhesion and spreading of HaCaTs. In contrast, additional nanostructuring with laser-induced periodic surface structures (LIPSS) promotes cell behavior. DC20 + LIPSS induced enhanced cell attachment with well-spread cell morphology. Thus, the bioinspired structures exhibited a benefit in initial cell adhesion. Laser surface functionalization opens up new possibilities for structuring, and is relevant to developing bioactive implants in regenerative medicine.

23 November 2022 in Foot & Ankle Specialist
Verified
Journal Article
Closed access
JSJan C. Schagemann
Jan C. Schagemann
HNHanjo Neumann
Hanjo Neumann
JSJana Schäfers
Jana Schäfers
APAndreas Paech
Andreas Paech
RWRobert Wendlandt
Robert Wendlandt
ASArndt Peter Schulz
Arndt Peter Schulz
Introduction: Biomechanical studies have proved that locking plates have better primary stability besides versatility regarding fracture pattern while reducing bone contact and bridging the gap, whereas conventional nonlocking plates (plus lag screw) depend on bone-plate compression. The clinical benefit of locking plates over nonlocking plates remains unanswered, however. Therefore, this retrospective cohort study was set up to test the hypothesis that the use of locking plates for unstable ankle fractures will result in fewer re-displacements, superior bony healing, and functional and clinical outcomes better than observed in the nonlocking cohort. Methods: Bimalleolar ankle fractures (AO 44-B2) without syndesmotic injury treated with either a locking or a nonlocking plate were included. Groups were compared for complications, bone healing, secondary dislocation, progressions of osteoarthritis, and clinical outcome using patient-reported outcome measures. Results: Data revealed no clinical outcome differences (Olerud-Molander Ankle Score: nonlocking 88.2 ± 14.4, locking 88.8 ± 12.3, P = .69, robust two 1-sided test for equality (RTOST): P = .03; American Orthopaedic Foot and Ankle Score: nonlocking 91.2 ± 12.9, locking 91.8 ± 11.3, P = .96, RTOST: P = .04). Nevertheless, a significant postoperative progression of osteoarthritis was detected in both groups (P = .04). This was independent of implant (P = .16). Although difference was not significant, locking plates were preferred in older (P = .78) and sicker patients (P = .63) and in cases with severer osteoarthritis (P = .16), and were associated with a higher complication rate (P = .42) and secondary dislocation (nonlocking 9.4%, locking 18.2%; P = .42). Re-displacement, however, was not a compelling reason for revision. Conclusions: The present study shows statistically significant equality of both types of implants. Contrary to our expectation, locking plates seemed to be associated with a higher risk for re-displacement. Overall, the use of either locking or nonlocking plates for unstable AO 44-B2 fractures is safe and successful despite significant progression of osteoarthritis. Level of Evidence: III, Retrospective observational cohort study

31 December 2010 in Injury Extra
Verified
Journal Article
Open access
RWRobert Wendlandt
Robert Wendlandt
KSK. Seide
K. Seide
ASA.P. Schulz
A.P. Schulz
NMN. Mueller
N. Mueller
CJC. Jürgens
C. Jürgens