A total of 66 smart implants were included. As a measure of bony stability, the relative elastic compliance of the osteosynthesis was determined from the gradient between the applied external load and the measured implant load over the entire healing process. The healing process of non-unions of the femur with a smart implant was tracked by telemetric measurements over a timespan of up to 10 years. The measurements of the longest healing process show a very slow but constant decrease in force transmission over the implant, radiological findings over 10 years show corresponding consolidation until bony healing. The use of a telemetrically instrumented bone plate, a so-called smart implant, to monitor the healing process is a successful procedure to support the clinician in his decision to take further surgical measures or to wait until healing occurs.
27 April 2024 in Archives of orthopaedic and trauma surgery
Introduction: Traditionally, plate osteosynthesis of the anterior column combined with an antegrade posterior column screw is used for fixation of anterior column plus posterior hemitransverse (ACPHT) acetabulum fractures. Replacing the posterior column screw with an infraacetabular screw could improve the straightforwardness of acetabulum surgery, as it can be inserted using less invasive approaches, such as the AIP/Stoppa approach, which is a well-established standard approach. However, the biomechanical stability of a plate osteosynthesis combined with an infraacetabular screw instead of an antegrade posterior column screw is unknown. Material and methods: Two osteosynthesis constructs were compared in a synthetic hemipelvis model with an ACPHT fracture: Suprapectineal plate + antegrade posterior column screw (APCS group) vs. suprapectineal plate + infraacetabular screw (IAS group). A single-leg stance test protocol with an additional passive muscle force and a cyclic loading of 32,000 cycles with a maximum effective load of 2400 N was applied. Interfragmentary motion and rotation of the three main fracture lines were measured. Results: At the posterior hemitransverse fracture line, interfragmentary motion perpendicular to the fracture line (p < 0.001) and shear motion (p < 0.001) and at the high anterior column fracture line, interfragmentary motion longitudinal to the fracture line (p = 0.017) were significantly higher in the IAS group than in the APCS group. On the other hand, interfragmentary motion perpendicular (p = 0.004), longitudinal (p < 0.001) and horizontal to the fracture line (p = 0.004) and shear motion (p < 0.001) were significantly increased at the low anterior column fracture line in the APCS group compared to the IAS group. Conclusions: Replacing the antegrade posterior column screw with an infraacetabular screw is not recommendable as it results in an increased interfragmentary motion, especially at the posterior hemitransverse component of an ACPHT fracture.
Besides the need for biomaterial surface modification to improve cellular attachment, laser-structuring is favorable for designing a new surface topography for external bone fixator pins or implants. The principle of this study was to observe how bioinspired (deer antler) laser-induced nano–microstructures influenced the adhesion and growth of skin cells. The goal was to create pins that allow the skin to attach to the biomaterial surface in a bacteria-proof manner. Therefore, typical fixator metals, steel, and titanium alloy were structured using ultrashort laser pulses, which resulted in periodical nano- and microstructures. Surface characteristics were investigated using a laser scanning microscope and static water contact angle measurements. In vitro studies with human HaCaT keratinocytes focused on cell adhesion, morphology, actin formation, and growth within 7 days. The study showed that surface functionalization influenced cell attachment, spreading, and proliferation. Micro-dimple clusters on polished bulk metals (DC20) will not hinder viability. Still, they will not promote the initial adhesion and spreading of HaCaTs. In contrast, additional nanostructuring with laser-induced periodic surface structures (LIPSS) promotes cell behavior. DC20 + LIPSS induced enhanced cell attachment with well-spread cell morphology. Thus, the bioinspired structures exhibited a benefit in initial cell adhesion. Laser surface functionalization opens up new possibilities for structuring, and is relevant to developing bioactive implants in regenerative medicine.
10 January 2022 in Biomedical Engineering / Biomedizinische Technik
This study has the aim to investigate the strain and stress in an anterolateral locking plate applied for the fixation of a lateral split fracture. To simulate a complex fracture situation, three segments were separated. With a FEM analysis, representative places for strain and stress measurement were determined. A locked osteosynthesis plate was instrumented with strain gauges and tested on a fractured and a non-fractured Saw Bone model. To simulate different loading situations, four different points of force application, from the center of the condyles to a 15 mm posterior position, were used with a medial-lateral load distribution of 60:40. The simulations as well as the biomechanical tests demonstrated that two deformations dominate the load on the plate: a bending into posterior direction and a bulging of the plate head. Shifting the point of application to the posterior direction resulted in increasing maximum stress, from 1.16 to 6.32 MPa (FEM analysis) and from 3.04 to 7.00 MPa (biomechanical study), respectively. Furthermore, the comparison of the non-fractured and fractured models showed an increase in maximum stress by the factor 2.06–2.2 (biomechanical investigation) and 1.5–3.3 (FEM analysis), respectively.
(1) Aim: This study aims to assess the repeatability and accuracy of a 9-axis IMU-based glove and an IR camera system, in order to determine their potential to replace traditional goniometry. (2) Background: Traditional methods for assessing hand function, such as goniometry, are time-consuming and limited by subjectivity, inter-rater variability and external factors that compromise accuracy and reliability. Recent advancements in motion capture technology and sensor-based devices offer potential improvements in efficiency and accuracy for hand rehabilitation assessment; (3) Methods: To evaluate the repeatability of an IMU-based glove and an IR camera, measurements were taken using a silicone hand model under controlled conditions, while accuracy assessments involved a volunteer without movement constraints. Bland–Altman plots were employed for visual comparison and accuracy evaluation; (4) Results: The Nuada glove exhibited high repeatability, with standard deviations below two degrees across all joints, surpassing the goniometer’s accuracy threshold of five degrees. The UltraLeap system demonstrated comparable repeatability, with deviations consistently under 3.5 degrees. Accuracy assessments revealed limitations: over 50% of the Nuada glove’s measurements and over 80% of UltraLeap’s measurements deviated by more than five degrees compared to the goniometer. However, the Nuada glove and UltraLeap system were more consistent with each other than with the goniometer, suggesting limitations in the goniometer’s reliability for modern mobility assessment; (5) Conclusions: Both devices exhibited excellent repeatability, highlighting their strong potential for clinical application. However, their accuracy compared to the goniometer requires further refinement. These findings suggest that these technologies could enhance traditional assessment methods, offering more efficient and accurate solutions for evaluating hand mobility in clinical settings.
Background: Considerable variation exists in the proximal and distal fixture designs used in biomechanical testing of diaphyseal femoral implants. In most of them a load is applied to the femoral head, but muscle forces are rarely represented, so bending of the diaphysis is unphysiologically high. Methods: This study investigated twelve testing configurations reported in the literature using finite element and analytical models of the femoral diaphysis and a lateral fixation plate. The models differed in proximal and distal displacement constraints, femoral orientation, and load application. Internal force distributions, as well as bone and implant stresses and bone strains, were calculated for each configuration. Results: Common experimental conditions, in which the load is applied to the femoral head, generally produced high bending moments, resulting in, what we interpret to be, unrealistically high bone and implant stresses and bone strains. In contrast, axial loading along the femoral shaft generated substantially lower bending, which we propose to be more physiological, particularly in two such cases with reduced rotational constraint. Conclusions: Their constant bending distribution should improve reproducibility and their implementation should provide a practical approach to biomechanical testing of diaphyseal femoral implants.