Kai Peng

Kai Peng


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2016 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XLXiaokang Liu
Xiaokang Liu
KPKai Peng
Kai Peng
ZCZiran Chen
Ziran Chen
HPHongji Pu
Hongji Pu
ZYZhicheng Yu
Zhicheng Yu
A highly stable motion with orthogonally alternating electric field is established to build the relationship between spatial displacement and time standards. Displacement is measured by counting the time pulses that serve as measurement standards. Thus, a displacement method is called time grating. An orthogonally alternating electric field is generated using two rows of differential capacitive sensing electrodes excited by four sinusoidal voltages. Sine-shaped grating planes rather than hyperfine grating lines are used to pick up the displacement signals. Electrode lead wires are designed below the middle of the electrodes and fabricated using multilayer thin-film technology to suppress the cross-sensitivity effect. A time-grating sensor has been fabricated to evaluate the proposed method. The range of measurement is 200 mm, the width of the electrode is 0.2 mm, the interval between two adjacent electrodes is 20 $\mu \text{m}$ , and the gap for capacitive sensing is 0.3 mm. Experimental results indicate that the measurement accuracy reaches ±200 nm with 1-nm resolution. Nanometer accuracy and resolution are achieved using sensing units with sub-millimeter periods. So, the cost for manufacturing the time-grating sensor can be decreased effectively in comparison to traditional nanometrology displacement sensors, and it may be a suitable low-cost alternative to long-range nanometrology.

27 April 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
KPKai Peng
Kai Peng
ZYZhicheng Yu
Zhicheng Yu
XLXiaokang Liu
Xiaokang Liu
ZCZiran Chen
Ziran Chen
HPHongji Pu
Hongji Pu
The capacitive displacement sensing method based on time grating employs a set of movable induction electrodes suspended with some gap width above a set of fixed excitation electrodes, and signals are obtained through electric field coupling. In this paper, we consider three features of time-grating capacitive displacement sensors that reduce the required manufacturing precision while maintaining high-accuracy measurements. First, the effect of edge roughness of the induction electrodes is suppressed by the filtering effect of the overlapping area integral method. Second, the effect of edge roughness of the excitation electrodes can be suppressed by the smoothing effect of the electric field. Third, the averaging effect of multiple induction electrodes is adopted to reduce the effect of geometric errors in the excitation electrodes. Printed circuit board manufacturing technology with a manufacturing accuracy on the order of 10 μm is selected to fabricate a prototype time-grating capacitive sensor, and a linearity of 0.005% is obtained for a single-period range of 0.8 mm. The measurement accuracy is largely independent of the manufacturing precision owing to the three aforementioned smoothing effects, which is promising for transforming the presently challenging technology of long-range displacement measurements with nanometer-scale accuracy into a conventional technology.

4 December 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ZYZhicheng Yu
Zhicheng Yu
KPKai Peng
Kai Peng
XLXiaokang Liu
Xiaokang Liu
ZCZiran Chen
Ziran Chen
YHYao Huang
Yao Huang

6 March 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HWHewen Wang
Hewen Wang
KPKai Peng
Kai Peng
XLXiaokang Liu
Xiaokang Liu
ZYZhicheng Yu
Zhicheng Yu
ZCZiran Chen
Ziran Chen
This paper proposes a compact and high precision capacitive absolute angular position sensor based on time grating. The sensor consists of a stator and a rotor with three concentric capacitor structures forming primary and auxiliary angular displacement measurement components. The primary component combines a single middle-row capacitive structure with an outer-row capacitive structure to obtain high-precision displacement measurements composed of N measurement periods. The auxiliary component employs a single inner-row capacitive structure with a single spatial period over the 360° measurement range of the sensor in conjunction with a remodulation scheme to obtain displacement measurements composed of N—1 measurement periods. Combining the measurements of the primary and auxiliary components in a manner similar to vernier calipers yields high-precision absolute angular position measurements. The sensor design and remodulation scheme facilitate good sensor compactness. The measurement performance of the proposed design is evaluated via tests of a prototype sensor with an outer diameter of 60 mm fabricated by printed circuit board technology. The prototype sensor is demonstrated to obtain a measurement resolution of 3″ and a measurement accuracy of ±10″ over the 360° measurement range of the sensor, indicating that the proposed sensor design has considerable potential for high precision applications.

18 January 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KPKai Peng
Kai Peng
XLXiaokang Liu
Xiaokang Liu
ZCZiran Chen
Ziran Chen
ZYZhicheng Yu
Zhicheng Yu
HPHongji Pu
Hongji Pu
In this paper, the sensing mechanism of a novel capacitive nanometer sensor based on the time grating approach is investigated. A mathematical model of the sensor is established using electric field coupling theory and the area integral method, which indicates that the measured displacement of the object is proportional to the phase shift of the output signal. High frequency time pulses serve as the measurement standard to realize the phase detection, and the displacement is measured by counting the time pulses. To evaluate the performance of the proposed sensor, periodic measurement errors are analyzed in detail. The primary periodic errors are quantified through the derivation of a mathematical error model. Experiments performed with a prototype sensor allow the causes of periodic first, second, and fourth harmonic errors to be traced back to cross interference, installation misalignment, and the effects of the electric field, respectively. After adopting a multilayer structure, adjusting the installation, and increasing the gap width to 0.3 mm, the primary periodic errors are sequentially eliminated. Therefore, the reasonability of the mathematical model and error analysis is validated by the designed experiments. Finally, the experimental results demonstrate that the measurement accuracy attains a value of ±200 nm over a 200 mm measurement range. This paper provides the theoretical guidance for the optimal design of high-performance time grating capacitive sensors.

21 May 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XFXingchen Fan
Xingchen Fan
ZYZhicheng Yu
Zhicheng Yu
KPKai Peng
Kai Peng
ZCZiran Chen
Ziran Chen
XLXiaokang Liu
Xiaokang Liu
The present work proposes a compact capacitive absolute angular displacement sensor design that adopts a stator and rotor configuration with a double capacitive ring structure, where the outer ring is composed of n measurement periods that function as a fine measurement component, providing high precision measurements. The inner ring is composed of a single measurement period that functions as a coarse measurement component, thereby providing an absolute position measurement. High measurement accuracy is obtained by adopting single-row excitation electrodes with induction electrodes that adopt a differential sensing structure to eliminate common-mode interference. In addition to the double-ring structure, the compact size of the proposed sensor is facilitated by integrating the electrodes of the stator and rotor and the peripheral circuits required for their respective signal processing using printed circuit board technology. A prototype of the proposed sensor is fabricated with outer and inner radii, and aggregate thickness dimensions of 30 mm, 7 mm, and less than 10 mm, respectively. The sensor design is optimized accordingly by increasing the radial interval between the outer and inner rings and adding shielding. Finally, the experimental results show that the optimized sensor design achieves a precision of 12″ and resolution of 0.31″ over the full measurement range of 0° to 360°. As such, the proposed sensor design is demonstrated to realize the small mechanical dimensions suffered by absolute angular displacement sensors. Accordingly, the relatively low cost and low power consumption of the proposed sensor have excellent potential for a wide variety of applications.