Hewen Wang

Dr. Hewen Wang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HWHewen Wang
Hewen Wang
KPKai Peng
Kai Peng
XLXiaokang Liu
Xiaokang Liu
ZYZhicheng Yu
Zhicheng Yu
ZCZiran Chen
Ziran Chen
This paper proposes a compact and high precision capacitive absolute angular position sensor based on time grating. The sensor consists of a stator and a rotor with three concentric capacitor structures forming primary and auxiliary angular displacement measurement components. The primary component combines a single middle-row capacitive structure with an outer-row capacitive structure to obtain high-precision displacement measurements composed of N measurement periods. The auxiliary component employs a single inner-row capacitive structure with a single spatial period over the 360° measurement range of the sensor in conjunction with a remodulation scheme to obtain displacement measurements composed of N—1 measurement periods. Combining the measurements of the primary and auxiliary components in a manner similar to vernier calipers yields high-precision absolute angular position measurements. The sensor design and remodulation scheme facilitate good sensor compactness. The measurement performance of the proposed design is evaluated via tests of a prototype sensor with an outer diameter of 60 mm fabricated by printed circuit board technology. The prototype sensor is demonstrated to obtain a measurement resolution of 3″ and a measurement accuracy of ±10″ over the 360° measurement range of the sensor, indicating that the proposed sensor design has considerable potential for high precision applications.

22 May 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
KPKai Peng
Kai Peng
ZDZhizhao Deng
Zhizhao Deng
XLXiaokang Liu
Xiaokang Liu
HWHewen Wang
Hewen Wang
ZYZhicheng Yu
Zhicheng Yu
Efforts to meet the demand for planar 2-D displacement measurement systems are limited by the difficulties of manufacturing 2-D diffraction gratings with high precision over a large area. The present work addresses this issue by capitalizing on the high-precision of 1-D capacitive displacement sensors based on time-grating to develop a planar 2-D capacitive displacement sensor technology composed of a large-area array of excitation electrodes positioned on a fixed ruler and a small-area array of induction electrodes assembled on a coplanar moving ruler that travels over the fixed ruler at a fixed separation gap. First, the individual traveling wave signals of the induction electrodes on the moving ruler are analyzed theoretically to develop a method for decoupling information pertaining to the separate displacements in the x - and y -directions. Then, the feasibility of the proposed decoupling method is verified by simulations based on a 3-D electric field model. Finally, the proposed measurement technology is validated experimentally based on tests conducted using a prototype sensor manufactured using standard printed circuit board technology. The experimental results demonstrate that the prototype sensor achieves measurement errors of ±8.2 μm and ±6.8 μm in the x - and y -directions, respectively, over the full 200 mm × 200 mm measurement range of the sensor.

13 March 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KPKai Peng
Kai Peng
BWBowen Wang
Bowen Wang
HPHongji Pu
Hongji Pu
HWHewen Wang
Hewen Wang
ZYZhicheng Yu
Zhicheng Yu
Considerable progress has been made in the development of absolute capacitive linear displacement sensors based on time grating that are capable of providing highly accurate absolute position measurements in conjunction with easy fabrication using standard printed circuit board (PCB) technology. However, the working range of currently available sensor designs has been rather limited. The present work addresses this issue by greatly expanding the measurement range via a technique for splicing multiple identical stationary rulers with individual measurement length of 600 mm. Here, absolute positioning is realized in a manner similar to that of Vernier calipers using stationary segments composed of periodic rectangular excitation electrodes with orthogonal excitation signals, and a moving component composed of sinusoidal-shaped induction electrodes. The sensor wiring is greatly simplified by transferring the induction signals output by the moving ruler to the stationary rulers via special transmitting and receiving electrodes. Splicing errors are eliminated by applying two sets of induction electrodes, including a front sensing unit (FSU) and a rear sensing unit (RSU), along the measurement direction on the moving ruler. The performance of the proposed design is evaluated experimentally using a two-segment prototype sensor fabricated by PCB technology. The results demonstrate that interference between the FSU and RSU generates a first harmonic error. This is then addressed by increasing the distance between the FSU and RSU, and enhancing the shielding layer between the two units. This yields a measurement accuracy of ±3.5 μm over the full 988 mm measurement range of the sensor.

26 May 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KPKai Peng
Kai Peng
XCXiaoyun Chen
Xiaoyun Chen
HWHewen Wang
Hewen Wang
LXLiang Xu
Liang Xu
XFXingchen Fan
Xingchen Fan
The use of multiple sensors for multidimensional measurements can introduce issues such as Abbe errors and installation difficulties. To address this, we introduce a cylindrical sensor that performs concurrent measurements of both linear and angular displacement. The sensor consists of two parts: a moving ruler and a fixed ruler. When the moving ruler moves linearly or rotates relative to the fixed one, the sensor can realize the simultaneous measurement of linear and angular displacement of the relative movement by calculating the inductive signal output from the moving ruler. By establishing a column surface displacement measurement model, this study characterized the inter-relationship between the phases of axial and circumferential electrical signals and actual displacement information, providing theoretical support for the design of a novel sensor structure. The feasibility of this measurement principle was validated through a simulation of the sensor model. A physical cylindrical sensor prototype was then manufactured using flexible printed circuit board technology, and a testing platform was built on which to perform linear and rotational movement synchronization experiments. The experimental results showed that this novel sensor exhibited a linear displacement measurement error of 34.8 μm over a distance of 100 mm, and an angular displacement measurement error of 68″ within an angle range of 0–360°. These results verified the accuracy of our earlier theoretical analysis and emulation.

3 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HPHongji Pu
Hongji Pu
XLXiaokang Liu
Xiaokang Liu
ZYZhicheng Yu
Zhicheng Yu
KPKai Peng
Kai Peng
HWHewen Wang
Hewen Wang
The present study builds upon a pre-proposed position sensor with nanometer-scale resolution and submicron level accuracy to directly obtain absolute positioning by optimizing its coarse measurement component. First, the coupling error caused by the spatially non-uniform electric field distribution is analyzed by building a two-dimensional electric field model. Theoretical analysis shows that the measurement error caused by the coupling of the non-uniform electric field is primarily a 4th-order harmonic error. Accordingly, we develop a method for suppressing the 4th order harmonic error using spatial phase shifting based on a sinusoidal electrode height modulation. Here, the coarse measurement component is divided effectively into two sensors with a spatial phase shift of π/4. This obtains two measurement values with 4th order harmonic errors of the same amplitude but opposite in sign, and two values are then averaged to form a new value with the 4th order harmonic error removed. Experimental results using a prototype sensor fabricated using printed circuit board technology demonstrate that the 4th order harmonic error is greatly reduced, and the measurement error of the coarse measurement component is reduced to about 1/7 of the original error prior to optimization. Therefore, the coarse measurement component can achieve direct absolute positioning. The absolute position maximum permissible error (MPE) of the sensor achieved was ±0.254 μm over a range of 200 mm after error compensation.

9 September 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HWHewen Wang
Hewen Wang
JZJilin Zhou
Jilin Zhou
KPKai Peng
Kai Peng
ZYZhicheng Yu
Zhicheng Yu
XFXingchen Fan
Xingchen Fan
Multidimensional angular displacement detection technology is essential for enabling the high-precision control of advanced spherical motors and ball hinges. However, existing conventional methods based on optical or electromagnetic principles are limited in their capacity for obtaining measurements in real time or in the ability to combine high accuracy with a large measurement range. This paper addresses these issues by proposing a novel spherical two-degree-of-freedom (2-DOF) angular displacement sensor that employs two distinct spherical electrode array configurations as the stator and rotor, respectively. The electrodes on the stator and rotor are separated by a short radial distance and represent capacitors with a capacitance that varies according to the area of overlap between the electrodes. Four two-phase orthogonal sinusoidal excitation signals of identical frequency and amplitude are applied along the two spatially orthogonal rotational angles (α and β) of the stator electrode array, respectively. As a result, each electrode in the rotor electrode array captures induced sinusoidal signals of identical frequency, whose phase characteristics are directly correlated with the rotational angles of the rotor in both the α and β directions. The induced signals from each rotor electrode are processed using a spatial phase combination method, which yields separate measurement signals Uoα, containing only angular displacement information for the α direction, and Uoβ, containing only angular displacement information for the angle β direction. Finally, the angular displacements of the rotor along the α and β directions are determined independently by extracting the phases from Uoα and Uoβ, respectively. Accuracy measurements on an experimental platform demonstrate that the calibrated sensor obtains a peak-to-peak error of 0.012° in the α and β directions over an entire ±20° measurement range in each direction.