4 December 2018 in IEEE Transactions on Industrial Electronics
6 March 2020 in IEEE Transactions on Industrial Electronics
This paper proposes a compact and high precision capacitive absolute angular position sensor based on time grating. The sensor consists of a stator and a rotor with three concentric capacitor structures forming primary and auxiliary angular displacement measurement components. The primary component combines a single middle-row capacitive structure with an outer-row capacitive structure to obtain high-precision displacement measurements composed of N measurement periods. The auxiliary component employs a single inner-row capacitive structure with a single spatial period over the 360° measurement range of the sensor in conjunction with a remodulation scheme to obtain displacement measurements composed of N—1 measurement periods. Combining the measurements of the primary and auxiliary components in a manner similar to vernier calipers yields high-precision absolute angular position measurements. The sensor design and remodulation scheme facilitate good sensor compactness. The measurement performance of the proposed design is evaluated via tests of a prototype sensor with an outer diameter of 60 mm fabricated by printed circuit board technology. The prototype sensor is demonstrated to obtain a measurement resolution of 3″ and a measurement accuracy of ±10″ over the 360° measurement range of the sensor, indicating that the proposed sensor design has considerable potential for high precision applications.
21 May 2020 in IEEE Sensors Journal
The present work proposes a compact capacitive absolute angular displacement sensor design that adopts a stator and rotor configuration with a double capacitive ring structure, where the outer ring is composed of n measurement periods that function as a fine measurement component, providing high precision measurements. The inner ring is composed of a single measurement period that functions as a coarse measurement component, thereby providing an absolute position measurement. High measurement accuracy is obtained by adopting single-row excitation electrodes with induction electrodes that adopt a differential sensing structure to eliminate common-mode interference. In addition to the double-ring structure, the compact size of the proposed sensor is facilitated by integrating the electrodes of the stator and rotor and the peripheral circuits required for their respective signal processing using printed circuit board technology. A prototype of the proposed sensor is fabricated with outer and inner radii, and aggregate thickness dimensions of 30 mm, 7 mm, and less than 10 mm, respectively. The sensor design is optimized accordingly by increasing the radial interval between the outer and inner rings and adding shielding. Finally, the experimental results show that the optimized sensor design achieves a precision of 12″ and resolution of 0.31″ over the full measurement range of 0° to 360°. As such, the proposed sensor design is demonstrated to realize the small mechanical dimensions suffered by absolute angular displacement sensors. Accordingly, the relatively low cost and low power consumption of the proposed sensor have excellent potential for a wide variety of applications.
22 May 2023 in IEEE Transactions on Industrial Electronics
Efforts to meet the demand for planar 2-D displacement measurement systems are limited by the difficulties of manufacturing 2-D diffraction gratings with high precision over a large area. The present work addresses this issue by capitalizing on the high-precision of 1-D capacitive displacement sensors based on time-grating to develop a planar 2-D capacitive displacement sensor technology composed of a large-area array of excitation electrodes positioned on a fixed ruler and a small-area array of induction electrodes assembled on a coplanar moving ruler that travels over the fixed ruler at a fixed separation gap. First, the individual traveling wave signals of the induction electrodes on the moving ruler are analyzed theoretically to develop a method for decoupling information pertaining to the separate displacements in the x - and y -directions. Then, the feasibility of the proposed decoupling method is verified by simulations based on a 3-D electric field model. Finally, the proposed measurement technology is validated experimentally based on tests conducted using a prototype sensor manufactured using standard printed circuit board technology. The experimental results demonstrate that the prototype sensor achieves measurement errors of ±8.2 μm and ±6.8 μm in the x - and y -directions, respectively, over the full 200 mm × 200 mm measurement range of the sensor.
6 June 2019 in IEEE Sensors Journal
This paper presents a high-precision absolute capacitive angular position sensor based on time grating. The sensor includes two single ring incremental type sensors arranged as outer and inner rings of capacitive arrays forming N and N - 1 measurement periods, respectively. The outer ring incremental sensor is employed as a fine measurement component to provide high-precision angular displacement values. The phase difference between the two incremental sensors is employed as a coarse measurement component to achieve absolute angular positioning according to a measurement principle similar to that of a vernier caliper. The proposed design is validated and optimized via tests conducted for a prototype sensor with N = 180 and a diameter of 154 mm fabricated using standard printed circuit board manufacturing technology. Based on these results, a differential induction electrode structure is proposed to greatly reduce the magnitude of crosstalk interference signals captured by the induction electrodes of one array produced by the lead wires of the excitation electrodes of the other array. The optimized sensor achieves absolute angular position measurements with an original measurement accuracy of ±2" over a full 360° measurement range. The proposed sensor has advantages of low cost, high measurement precision, simple positioning method, and ease of manufacture.
25 January 2021 in IEEE Sensors Journal
In this paper, an absolute time-grating displacement sensor with high accuracy and high resolution is proposed, where primary, secondary, and tertiary stage capacitor arrays with M, N, and N -1 measurement periods, respectively, are combined by a multi-stage composite method that applies the four orthogonal traveling wave signals output by the primary-stage as the excitation signals of the secondary and tertiary stages. Combining the primary and secondary stages yields sensor A, with M + N measurement periods. Similarly, sensor B, composed of the primary and tertiary stages, has M + N -1 measurement periods. Sensor A is used as the fine measurement component, and the phase difference between sensors A and B is used as the coarse measurement component. Absolute positioning is realized in a similar manner to a Vernier caliper measurement. The output signal of each stage includes odd harmonics, such that the measurement error of each stage contains the fourth harmonic. This is retained in the synthesis stage by the multi-stage composite method. Experimental results for a prototype sensor yield an absolute positioning error of ±200 nm over a measurement range of 200 mm. Depending on the multi-stage composite method, the measurement accuracy and resolution of the same size time-grating are improved, and the connection of the input and output are focused on a stationary component. This compact and convenient sensor has wider application prospects for machine tools and automatic machine systems.