Xiaokang Liu

Dr. Xiaokang Liu


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ZYZhicheng Yu
Zhicheng Yu
KPKai Peng
Kai Peng
XLXiaokang Liu
Xiaokang Liu
ZCZiran Chen
Ziran Chen
YHYao Huang
Yao Huang

6 March 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HWHewen Wang
Hewen Wang
KPKai Peng
Kai Peng
XLXiaokang Liu
Xiaokang Liu
ZYZhicheng Yu
Zhicheng Yu
ZCZiran Chen
Ziran Chen
This paper proposes a compact and high precision capacitive absolute angular position sensor based on time grating. The sensor consists of a stator and a rotor with three concentric capacitor structures forming primary and auxiliary angular displacement measurement components. The primary component combines a single middle-row capacitive structure with an outer-row capacitive structure to obtain high-precision displacement measurements composed of N measurement periods. The auxiliary component employs a single inner-row capacitive structure with a single spatial period over the 360° measurement range of the sensor in conjunction with a remodulation scheme to obtain displacement measurements composed of N—1 measurement periods. Combining the measurements of the primary and auxiliary components in a manner similar to vernier calipers yields high-precision absolute angular position measurements. The sensor design and remodulation scheme facilitate good sensor compactness. The measurement performance of the proposed design is evaluated via tests of a prototype sensor with an outer diameter of 60 mm fabricated by printed circuit board technology. The prototype sensor is demonstrated to obtain a measurement resolution of 3″ and a measurement accuracy of ±10″ over the 360° measurement range of the sensor, indicating that the proposed sensor design has considerable potential for high precision applications.

12 June 2015 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZCZiran Chen
Ziran Chen
HPHongji Pu
Hongji Pu
XLXiaokang Liu
Xiaokang Liu
DPDonglin Peng
Donglin Peng
ZYZhicheng Yu
Zhicheng Yu
It is difficult to achieve long measurement range with high precision in displacement measurement, a new nanometer displacement sensor, named time grating, is proposed to tackle this problem. The proposed displacement sensor uses orthogonally alternating electric fields as the carrier to build the relationship between the object movement in space domain and the signal phase shift in time domain, and the moving displacement of the object is proportional to the phase shift of the composited traveling wave signal that can be measured by time difference. The electric-field distribution of the sensor is simulated to analyze the influences of various factors, such as electrode intervals and electrode width. The results are further validated with experiments. The error characteristics are extracted using error identification technology and traced back to the sensor model, thus the relationships between the error characteristics and the model parameters are obtained. The experiment results prove that the measuring precision reaches ±200 nm and the resolution reaches 1 nm within 200 mm. Submillimeter period sensing unit realizing nanometer precision and resolution has shown significant promise in fabricating large range nanometer displacement sensors with low cost.

18 January 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KPKai Peng
Kai Peng
XLXiaokang Liu
Xiaokang Liu
ZCZiran Chen
Ziran Chen
ZYZhicheng Yu
Zhicheng Yu
HPHongji Pu
Hongji Pu
In this paper, the sensing mechanism of a novel capacitive nanometer sensor based on the time grating approach is investigated. A mathematical model of the sensor is established using electric field coupling theory and the area integral method, which indicates that the measured displacement of the object is proportional to the phase shift of the output signal. High frequency time pulses serve as the measurement standard to realize the phase detection, and the displacement is measured by counting the time pulses. To evaluate the performance of the proposed sensor, periodic measurement errors are analyzed in detail. The primary periodic errors are quantified through the derivation of a mathematical error model. Experiments performed with a prototype sensor allow the causes of periodic first, second, and fourth harmonic errors to be traced back to cross interference, installation misalignment, and the effects of the electric field, respectively. After adopting a multilayer structure, adjusting the installation, and increasing the gap width to 0.3 mm, the primary periodic errors are sequentially eliminated. Therefore, the reasonability of the mathematical model and error analysis is validated by the designed experiments. Finally, the experimental results demonstrate that the measurement accuracy attains a value of ±200 nm over a 200 mm measurement range. This paper provides the theoretical guidance for the optimal design of high-performance time grating capacitive sensors.

21 May 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XFXingchen Fan
Xingchen Fan
ZYZhicheng Yu
Zhicheng Yu
KPKai Peng
Kai Peng
ZCZiran Chen
Ziran Chen
XLXiaokang Liu
Xiaokang Liu
The present work proposes a compact capacitive absolute angular displacement sensor design that adopts a stator and rotor configuration with a double capacitive ring structure, where the outer ring is composed of n measurement periods that function as a fine measurement component, providing high precision measurements. The inner ring is composed of a single measurement period that functions as a coarse measurement component, thereby providing an absolute position measurement. High measurement accuracy is obtained by adopting single-row excitation electrodes with induction electrodes that adopt a differential sensing structure to eliminate common-mode interference. In addition to the double-ring structure, the compact size of the proposed sensor is facilitated by integrating the electrodes of the stator and rotor and the peripheral circuits required for their respective signal processing using printed circuit board technology. A prototype of the proposed sensor is fabricated with outer and inner radii, and aggregate thickness dimensions of 30 mm, 7 mm, and less than 10 mm, respectively. The sensor design is optimized accordingly by increasing the radial interval between the outer and inner rings and adding shielding. Finally, the experimental results show that the optimized sensor design achieves a precision of 12″ and resolution of 0.31″ over the full measurement range of 0° to 360°. As such, the proposed sensor design is demonstrated to realize the small mechanical dimensions suffered by absolute angular displacement sensors. Accordingly, the relatively low cost and low power consumption of the proposed sensor have excellent potential for a wide variety of applications.

1 May 2018 in Mechanical Systems and Signal Processing
Verified
Journal Article
Closed access
HPHongji Pu
Hongji Pu
HLHongzhong Liu
Hongzhong Liu
XLXiaokang Liu
Xiaokang Liu
KPKai Peng
Kai Peng
ZYZhicheng Yu
Zhicheng Yu