Ángela Bermúdez Bermúdez Castañeda

Dr. Ángela Bermúdez Bermúdez Castañeda


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2021 in Materials
Verified
Journal Article
Open access
PDF file
ABAngela Bermudez-Castañeda
Angela Bermudez-Castañeda
AMAnna Igual Munoz
Anna Igual Munoz
SMStefano Mischler
Stefano Mischler
Modular hip joint implants were introduced in arthroplasty medical procedures because they facilitate the tailoring of patients’ anatomy, the use of different materials in one single configuration, as well as medical revision. However, in certain cases, such prostheses may undergo deterioration at the head–neck junctions with negative clinical consequences. Crevice-corrosion is commonly invoked as one of the degradation mechanisms acting at those junctions despite biomedical alloys such as Ti6Al4V and CoCr being considered generally resistant to this form of corrosion. To verify the occurrence of crevice corrosion in modular hip joint junctions, laboratory crevice-corrosion tests were conducted in this work under hip joint-relevant conditions, i.e., using similar convergent crevice geometries, materials (Ti6Al4V and CoCr alloys vs. ceramic), surface finish, NaCl solution pHs (5.6 and 2.3), and electrochemical conditions. A theoretical model was also developed to describe crevice-corrosion considering relevant geometrical and electrochemical parameters. To verify the model, a FeCr alloy, known to be sensitive to this phenomenon, was subjected to the crevice-corrosion test in sulfuric acid. The experiments and the model predictions clearly showed that, in principle, crevice corrosion of Ti6Al4V or CoCr is not supposed to occur in typical crevices formed at the stem-neck junction of hip implants.

4 March 2026 in Waste and Biomass Valorization
Verified
Journal Article
Closed access
PDF file
CPC. A. Pino
C. A. Pino
JEJ. Esguerra-Arce
J. Esguerra-Arce
VAV. Amigó
V. Amigó
EKE. Klyatskina
E. Klyatskina
CAC. Ayala-Garcia
C. Ayala-Garcia
ABAngela Bermudez-Castañeda
Angela Bermudez-Castañeda

27 July 2022 in Ingenieria y Universidad
Verified
Journal Article
Open access
PDF file
DBDavid Leonardo Blanco-Estupiñan
David Leonardo Blanco-Estupiñan
ABAngela Bermudez-Castañeda
Angela Bermudez-Castañeda
SMSebastián Marquez
Sebastián Marquez
Objetivo: evaluar la resistencia a la corrosión de las boquillas de inyección de acero inoxidable bajo ensayo de inmersión en biodiésel, y realizar una caracterización electroquímica bajo soluciones de HNO3. Métodos y materiales: Se realizó la caracterización química del biodiésel para analizar su estabilidad. Se realizaron pruebas de inmersión durante 4 meses, evaluando el acero inoxidable 304 bajo 3 concentraciones diferentes de mezclas de diésel/biocombustible. Además, se realizaron ensayos de polarización con concentraciones de NOx superiores a los niveles medidos en las emisiones de los motores. Resultados y discusión: El uso de biocombustibles en Colombia ha sido impulsado en gran medida por la producción de etanol de origen vegetal. Su uso aporta algunas ventajas relacionadas con la reducción de las emisiones de partículas y gases tóxicos (principalmente, grupos aromáticos, NOx y CO2). Sin embargo, puede producirse una degradación de los materiales cuando están en contacto directo con el biodiésel. Además, se ha informado de solidificación de ceras, que provoca el taponamiento de las boquillas. No obstante, se desconoce si esto influye en la difusión del oxígeno en la solución y, a su vez, afecta a la resistencia a la corrosión del acero inoxidable. Conclusiones: La resistencia a la corrosión del acero inoxidable 304 cambió bajo condiciones de inmersión, aunque su capa protectora no se vio afectada por las concentraciones de NOx registradas en las mezclas de biocombustible.

23 March 2021 in Revista Facultad de Ingeniería Universidad de Antioquia
Verified
Journal Article
Open access
PDF file
ABAngela Bermudez-Castañeda
Angela Bermudez-Castañeda
JEJohanna Esguerra-Arce
Johanna Esguerra-Arce
AEAdriana Esguerra-Arce
Adriana Esguerra-Arce
SVSofia Valentina Vargas-Pabón
Sofia Valentina Vargas-Pabón
JOJuan Guillermo Ortiz-Martínez
Juan Guillermo Ortiz-Martínez
SMStefano Mischler
Stefano Mischler
The introduction of modular design in total hip arthroplasty has enabled the use of different materials in one single configuration and the adjustment of the prosthesis to the patient’s body, and facilitated medical revisions. However, modularity leads to the presence of new interfaces created between pieces in contact, raising the issue of degradation. Tribocorrosion phenomena have been identified as the main degradation mechanism due to the mechanical, chemical, and electrochemical conditions acting on the materials. In addition, conditions inside the human body are unclear, regarding electrochemical settings and the interaction between the electrochemical and mechanical action. This work is focused on the degradation of monopolar hip joint implants made from biomedical alloys such as stainless steel, Ti, and CoCr alloys. Three cases are presented and analyzed in terms of the degradation level along the trunnion length. Surface analysis done on a titanium trunnion showed a significant ploughing on the distal part, compared to what was found for stainless Steel and cobalt-chromium alloys, which can produce a stuck in this area. Meanwhile, in the proximal part, wear debris is found, which suggests more movement in the internal part. Although few debris particles were identified in CoCr trunnion, a large amount of material inside the contact was observed. This could be related to the ploughing generated in the distal thread pattern, which allowed the material to come inside and outside the contact.

13 October 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MVMaria Vinogradova
Maria Vinogradova
EKElizaveta Klyatskina
Elizaveta Klyatskina
ABAngela Bermudez-Castañeda
Angela Bermudez-Castañeda
FSFrancisco Segovia-López
Francisco Segovia-López
Vicente Amigo BorrasVicente Amigo Borras
Vicente Amigo Borras
Ti-35Nb-xSn (x = 0, 4, 6 wt.%) alloys were consolidated by Electrical Resistance Sintering (ERS) at 11 and 12 kA to address the elastic-modulus mismatch and ion-release limitations of Ti-6Al-4V, exploiting the β-stabilizing effect of Nb and oxide-reinforcing effect of Sn. As the corrosion and tribocorrosion behavior of ERS-processed Ti-Nb-Sn alloys has not previously been reported, this study evaluated the combined effect of Sn content and sintering current on static corrosion resistance, tribocorrosion, wear, and ion release in Hartmann–Ringer solution and sulfuric acid. Rietveld refinement revealed a disproportionate increase in α-Ti fraction for the 6 wt.% Sn alloy sintered at 12 kA (41.2 wt.% vs. 29.3 wt.% at 11 kA), coinciding with a shift from smeared, ductile wear debris at 11 kA to coarser, fractured debris at 12 kA, and with an inversion of the sintering-current effect on static corrosion resistance between Sn-free and Sn-containing alloys. The alloy with 6 wt.% Sn sintered at 11 kA showed the best overall performance, combining the highest corrosion resistance, the lowest wear volume loss in sulfuric acid, and stable post-tribocorrosion microhardness, while showing comparable wear resistance to the 4 and 6 wt.% Sn alloys sintered at 12 kA in Hartmann–Ringer solution. Ion release rates remained in the range reported for comparable Ti-Nb-Sn biomedical alloys, supporting the biocompatibility potential of the studied compositions.

21 August 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
MVMaria Vinogradova
Maria Vinogradova
EKElizaveta Klyatskina
Elizaveta Klyatskina
ABAngela Bermudez-Castañeda
Angela Bermudez-Castañeda
FSFrancisco Segovia-López
Francisco Segovia-López
Vicente Amigo BorrasVicente Amigo Borras
Vicente Amigo Borras
Ti35NbxSn alloys produced via Electrical Resistance Sintering were evaluated for their potential in biomedical applications, particularly dental implants. The study focused on the effects of Sn content and sintering current on electrochemical properties and tribocorrosion behaviour. Testing in Hartmann-Ringer solution and sulfuric acid showed that alloys with 6 wt.% Sn sintered at 11 kA offered the best performance, demonstrating superior corrosion resistance, minimal wear rates, and stable microhardness. Sn significantly enhanced the stability of passive oxide films, aiding in repassivation during slide. Ion release remained below acceptable levels, indicating biocompatibility.