Environmental chemicals and contaminants coming from multiple external sources enter the human body, determining a potential risk for human health. Human biomonitoring (HBM), measuring the concentrations of biomarkers in human specimens, has become an emerging approach for assessing population-wide exposure to hazardous chemicals and health risk through large-scale studies in many countries. However, systematic mapping of HBM studies, including their characteristics, targeted hazardous pollutants, analytical techniques, and sample population (general population and occupationally exposed workers), has not been done so far. We conducted a systematic review of the literature related to airborne hazardous pollutants in biofluids to answer the following questions: Which main chemicals have been included in the literature, which bodily fluids have been used, and what are the main findings? Following PRISMA protocol, we summarized the publications published up to 4 February 2021 of studies based on two methods: gas-chromatography/mass spectrometry (GC/MS) and electronic noses (e-noses). We screened 2606 records and 117 publications were included in the analysis, the most based on GC/MS analysis. The selected HBM studies include measurements of biomarkers in different bodily fluids, such as blood, urine, breast milk, and human semen as well as exhaled air. The papers cover numerous airborne hazardous pollutants that we grouped in chemical classes; a lot of hazardous and noxious compounds, mainly persistent organic pollutants (POPs) and volatile organic compounds (VOCs), have been detected in biological fluids at alarming levels. The scenario that emerged from this survey demonstrates the importance of HBM in human exposure to hazardous pollutants and the need to use it as valid tool in health surveillance. This systematic review represents a starting point for researchers who focus on the world of pollutant biomonitoring in the human body and gives them important insights into how to improve the methods based on GC/MS. Moreover, it makes a first overview of the use of gas sensor array and e-noses in HBM studies.
A novel and low-cost framework for food traceability, composed by commercial and proprietary sensing devices, for the remote monitoring of air, water, soil parameters and herbicide contamination during the farming process, has been developed and verified in real crop environments. It offers an integrated approach to food traceability with embedded systems supervision, approaching the problem to testify the quality of the food product. Moreover, it fills the gap of missing low-cost systems for monitoring cropping environments and pesticides contamination, satisfying the wide interest of regulatory agencies and final customers for a sustainable farming. The novelty of the proposed monitoring framework lies in the realization and the adoption of a fully automated prototype for in situ glyphosate detection. This device consists of a custom-made and automated fluidic system which, leveraging on the Molecularly Imprinted Polymer (MIP) sensing technology, permits to detect unwanted glyphosate contamination. The custom electronic mainboard, called ElectroSense, exhibits both the potentiostatic read-out of the sensor and the fluidic control to accomplish continuous unattended measurements. The complementary monitored parameters from commercial sensing devices are: temperature, relative humidity, atmospheric pressure, volumetric water content, electrical conductivity of the soil, pH of the irrigation water, total Volatile Organic Compounds (VOCs) and equivalent CO. The framework has been validated during the olive farming activity in an Italian company, proving its efficacy for food traceability. Finally, the system has been adopted in a different crop field where pesticides treatments are practiced. This has been done in order to prove its capability to perform first level detection of pesticide treatments. Good correlation results between chemical sensors signals and pesticides treatments are highlighted.
Monitoring of ions in real-time directly in cell culture systems and in organ-on-a-chip platforms represents a significant investigation tool to understand ion regulation and distribution in the body and ions’ involvement in biological mechanisms and specific pathologies. Innovative flexible sensors coupling electrochemical stripping analysis (square wave anodic stripping voltammetry, SWASV) with an ion selective membrane (ISM) were developed and integrated in Transwell™ cell culture systems to investigate the transport of zinc and copper ions across a human intestinal Caco-2 cell monolayer. The fabricated ion-selective sensors demonstrated good sensitivity (1 × 10−11 M ion concentration) and low detection limits, consistent with pathophysiological cellular concentration ranges. A non-invasive electrochemical impedance spectroscopy (EIS) analysis, in situ, across a selected spectrum of frequencies (10–105 Hz), and an equivalent circuit fitting were employed to obtain useful electrical parameters for cellular barrier integrity monitoring. Transepithelial electrical resistance (TEER) data and immunofluorescent images were used to validate the intestinal epithelial integrity and the permeability enhancer effect of ethylene glycol-bis(2-aminoethylether)-N,N,N’,N’-tetraacetic acid (EGTA) treatment. The proposed devices represent a real prospective tool for monitoring cellular and molecular events and for studies on gut metabolism/permeability. They will enable a rapid integration of these sensors into gut-on-chip systems.
Surface electromyography (sEMG) is increasingly important for prevention, diagnosis, and rehabilitation in healthcare. The continuous monitoring of muscle electrical activity enables the detection of abnormal events, but existing sEMG systems often rely on disposable pre-gelled electrodes that can cause skin irritation and require precise placement by trained personnel. Wearable sEMG systems integrating textile electrodes have been proposed to improve usability; however, they often suffer from poor skin–electrode coupling, leading to higher impedance, motion artifacts, and reduced signal quality. To address these limitations, we propose a preliminary model of smart socks, integrating biocompatible hybrid polymer electrodes positioned over the target muscles. Compared with commercial Ag/AgCl electrodes, these hybrid electrodes ensure lower the skin–electrode impedance, enhancing signal acquisition (19.2 ± 3.1 kΩ vs. 27.8 ± 4.5 kΩ for Ag/AgCl electrodes). Moreover, to the best of our knowledge, this is the first wearable system incorporating hydrogel-based electrodes in a sock specifically designed for the analysis of lower limb muscles, which are crucial for evaluating conditions such as sarcopenia, fall risk, and gait anomalies. The system incorporates a lightweight, wireless commercial module for data pre-processing and transmission. sEMG signals from the Gastrocnemius and Tibialis muscles were analyzed, demonstrating a strong correlation (R = 0.87) between signals acquired with the smart socks and those obtained using commercial Ag/AgCl electrodes. Future studies will further validate its long-term performance under real-world conditions and with a larger dataset.
The integration of sensing devices into cell culture systems is a topic of great interest in the study of pathologies and complex biological mechanisms in real-time. In particular, the fit-for-purpose microfluidic devices called organ-on-chip (OoC), which host living engineered organs that mimic in vivo conditions, benefit greatly from the integration of sensors, enabling the monitoring of specific chemical-physical parameters that can be correlated with biological processes. In this context, copper is an essential trace element whose total concentration may be associated with specific pathologies, and it is therefore important to develop reliable analytical techniques in cell systems. Copper can be determined by using the anodic stripping voltammetry (ASV) technique, but its applicability in cell culture media presents several challenges. Therefore, in this work, the performance of ASV in cell culture media was evaluated, and an acidification protocol was tested to improve the voltammetric signal intensity. A Transwell® culture model with Caco-2 cells was used to test the applicability of the developed acidification protocol by performing an off-line measurement. Finally, a microfluidic device was designed in order to perform the acidification of the cell culture medium in an automated manner and then integrated with a silicon microelectrode to perform in situ measurements. The resulting sensor-integrated microfluidic chip could be used to monitor the concentration of copper or other ions concentration in an organ-on-chip model; these functionalities represent a great opportunity for the non-destructive strategic experiments required on biological systems under conditions close to those in vivo.