Elisa Sciurti

Dr. Elisa Sciurti

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
ESElisa Sciurti
Elisa Sciurti
LBLaura Blasi
Laura Blasi
Carmela Tania PronteraCarmela Tania Prontera
Carmela Tania Prontera
Amilcare BarcaAmilcare Barca
Amilcare Barca
LGLucia Giampetruzzi
Lucia Giampetruzzi
Luca FranciosoLuca Francioso
Luca Francioso
Monitoring of ions in real-time directly in cell culture systems and in organ-on-a-chip platforms represents a significant investigation tool to understand ion regulation and distribution in the body and ions’ involvement in biological mechanisms and specific pathologies. Innovative flexible sensors coupling electrochemical stripping analysis (square wave anodic stripping voltammetry, SWASV) with an ion selective membrane (ISM) were developed and integrated in Transwell™ cell culture systems to investigate the transport of zinc and copper ions across a human intestinal Caco-2 cell monolayer. The fabricated ion-selective sensors demonstrated good sensitivity (1 × 10−11 M ion concentration) and low detection limits, consistent with pathophysiological cellular concentration ranges. A non-invasive electrochemical impedance spectroscopy (EIS) analysis, in situ, across a selected spectrum of frequencies (10–105 Hz), and an equivalent circuit fitting were employed to obtain useful electrical parameters for cellular barrier integrity monitoring. Transepithelial electrical resistance (TEER) data and immunofluorescent images were used to validate the intestinal epithelial integrity and the permeability enhancer effect of ethylene glycol-bis(2-aminoethylether)-N,N,N’,N’-tetraacetic acid (EGTA) treatment. The proposed devices represent a real prospective tool for monitoring cellular and molecular events and for studies on gut metabolism/permeability. They will enable a rapid integration of these sensors into gut-on-chip systems.

1 May 2020 in Microelectronic Engineering
Verified
Journal Article
Closed access
ESElisa Sciurti
Elisa Sciurti
RPR. Primavera
R. Primavera
DMD. Di Mascolo
D. Di Mascolo
ARA. Rizzo
A. Rizzo
ABAntonio Balena
Antonio Balena
MVM. De Vittorio
M. De Vittorio

26 March 2024 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
MSmaria assunta signore
maria assunta signore
ASA Serra
A Serra
DMDaniela Erminia MANNO
Daniela Erminia MANNO
Gianluca QuartaGianluca Quarta
Gianluca Quarta
LCLucio Calcagnile
Lucio Calcagnile
LVLuciano Velardi
Luciano Velardi
This work investigates the physical properties of Al1−xScxN thin films sputtered at low temperatures by varying the process conditions. Specifically, the films were deposited at room temperature by applying a radio frequency power equal to 150 W to an AlSc alloy (60:40) target, varying the nitrogen flux percentage in the (Ar + N2) sputtering atmosphere (30%, 40%, 50%, and 60%) and keeping constant the working pressure at 5 × 10−3 mbar. The structural and chemical properties of the Al1−xScxN films were studied by x-ray diffraction and Rutherford backscattering spectrometry techniques, respectively. The piezoelectric response was investigated by piezoresponse force microscopy. In addition, the surface potential was evaluated for the first time for Sc-doped AlN thin films by Kelvin probe force microscopy, providing piezoelectric coefficients free from the no-piezoelectric additional effect to the mechanical deformation, i.e., the electrostatic force. By alloying AlN with scandium, the piezoelectric response was strongly enhanced (up to 200% compared to undoped AlN), despite the low deposition temperature and the absence of any other additional energy source supplied to the adatoms during thin film growth, which generally promotes a better structural arrangement of polycrystalline film. This is a strategic result in the field of microelectromechanical systems completely fabricated at low temperatures.

4 February 2024 in Talanta
Verified
Journal Article
Closed access
ESElisa Sciurti
Elisa Sciurti
MSM.A. Signore
M.A. Signore
LVLuciano Velardi
Luciano Velardi
RCRiccardo Di Corato
Riccardo Di Corato
LBLaura Blasi
Laura Blasi
LFL. Francioso
L. Francioso

20 March 2024 in Electronics
Verified
Journal Article
Open access
PDF file
Antonio Vincenzo RadognaAntonio Vincenzo Radogna
Antonio Vincenzo Radogna
Luca FranciosoLuca Francioso
Luca Francioso
ESElisa Sciurti
Elisa Sciurti
DBDaniele Bellisario
Daniele Bellisario
VEVanessa Esposito
Vanessa Esposito
GGGiuseppe Grassi
Giuseppe Grassi
In this paper, a wireless potentiostat code-named ElectroSense, for interfacing of wearable electrochemical biosensors, will be presented. The system is devoted to non-invasive monitoring of glucose in wearable medical applications. Differently from other potentiostats in literature, which use digital-to-analog converters (DACs) as discrete components or integrated in high-end microcontrollers, in this work the pulse width modulation (PWM) technique is exploited through PWM-DAC approach to generate signals. The ubiquitous presence of integrated PWM peripherals in low-end microcontrollers, which generally also integrate analog-to-digital converters (ADCs), enables both the generation and acquisition of read-out signals on a single cheap electronic device without additional hardware. By this way, system’s production costs, power consumption, and system’s size are greatly reduced with respect to other solutions. All these features allow the system’s adoption in wearable healthcare Internet-of-things (IoT) ecosystems. A description of both the sensing technology and the circuit will be discussed in detail, emphasizing advantages and drawbacks of the PWM-DAC approach. Experimental measurements will prove the efficacy of the proposed electronic system for non-invasive monitoring of glucose in wearable medical applications.

6 March 2025 in Sensors
Verified
Journal Article
Open access
PDF file
GRGabriele Rescio
Gabriele Rescio
ESElisa Sciurti
Elisa Sciurti
LGLucia Giampetruzzi
Lucia Giampetruzzi
ACAnna Maria Carluccio
Anna Maria Carluccio
Luca FranciosoLuca Francioso
Luca Francioso
Alessandro LeoneAlessandro Leone
Alessandro Leone
Surface electromyography (sEMG) is increasingly important for prevention, diagnosis, and rehabilitation in healthcare. The continuous monitoring of muscle electrical activity enables the detection of abnormal events, but existing sEMG systems often rely on disposable pre-gelled electrodes that can cause skin irritation and require precise placement by trained personnel. Wearable sEMG systems integrating textile electrodes have been proposed to improve usability; however, they often suffer from poor skin–electrode coupling, leading to higher impedance, motion artifacts, and reduced signal quality. To address these limitations, we propose a preliminary model of smart socks, integrating biocompatible hybrid polymer electrodes positioned over the target muscles. Compared with commercial Ag/AgCl electrodes, these hybrid electrodes ensure lower the skin–electrode impedance, enhancing signal acquisition (19.2 ± 3.1 kΩ vs. 27.8 ± 4.5 kΩ for Ag/AgCl electrodes). Moreover, to the best of our knowledge, this is the first wearable system incorporating hydrogel-based electrodes in a sock specifically designed for the analysis of lower limb muscles, which are crucial for evaluating conditions such as sarcopenia, fall risk, and gait anomalies. The system incorporates a lightweight, wireless commercial module for data pre-processing and transmission. sEMG signals from the Gastrocnemius and Tibialis muscles were analyzed, demonstrating a strong correlation (R = 0.87) between signals acquired with the smart socks and those obtained using commercial Ag/AgCl electrodes. Future studies will further validate its long-term performance under real-world conditions and with a larger dataset.