Martina Cicolini

Dr. Martina Cicolini

Department of Applied Science and Technology (DISAT), Politecnico di Torino, Turin, Piedmont, Italy
orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2025 in ACS Sensors
Verified
Journal Article
Open access
MCMartina Cicolini
Martina Cicolini
ASAli Solgi
Ali Solgi
LVLorenzo Vigna
Lorenzo Vigna
ABAlberto Ballesio
Alberto Ballesio
SMSimone Luigi Marasso
Simone Luigi Marasso
LNLucia Napione
Lucia Napione
Paper-based biosensors hold significant promise for point-of-care (POC) diagnostic applications. Among these, lateral flow assays (LFAs) are particularly appealing due to their ease of use, portability, and low cost. However, their limited sensitivity and qualitative output set drawbacks on their reliability and widespread application. In response to the growing need for rapid and consistent diagnostic and monitoring tools, Organic Electrochemical Transistors (OECTs) have emerged as powerful devices in biochemical sensing applications because of their high sensitivity, low operating voltage, and compatibility with a biological environment. In this work, we developed a printable OECT for biochemical sensing on a commercial cellulose membrane, commonly used as a detection substrate in LFA-based rapid tests. Constituting a self-standing, passive microfluidic platform, the system was designed to transport and interact with liquid samples, while ensuring a contamination-free zone for the active components. Inside a dry area delimited by a hydrophobic barrier, the OECT components include dispense-printed silver electrodes, a polystyrenesulfonate-doped poly(3,4-ethylenedioxy-thiophene) (PEDOT:PSS) channel and gate, and a solid-state electrolyte (SSE) layer. Outside the dry area, a PEDOT:PSS extended gate alone interacts with the analyte in the liquid sample, preventing channel contamination and enhancing the system stability. We investigated the effect of dopamine (DA) oxidation at the extended gate interface on the device response and observed variations in the transfer characteristics, transconductance and Ion/Ioff ratio, obtaining a limit of detection of 0.01 mM. With a maximum transconductance of approximately 4 mS, our system shows potential for the integration of an easy-to-fabricate device into an affordable biochemical assay, providing quantitative results at the point-of-care site to complement and reinforce the typical colorimetric response of LFAs.

30 July 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
MCMichele Campanini
Michele Campanini
LVLorenzo Vigna
Lorenzo Vigna
DVDavide Vurro
Davide Vurro
Pasquale D'AngeloPasquale D'Angelo
Pasquale D'Angelo
MCMartina Cicolini
Martina Cicolini
ABAlberto Ballesio
Alberto Ballesio
Organic Electrochemical Transistors (OECTs) have emerged as continuous monitoring sensors for in-vitro models. Source and Measure Units (SMUs) are typical instruments used to simultaneously control input and output signals on OECTs. Conventional SMUs are unsuitable for in-vitro application due to their limited channels count, large footprint and high cost. This work presents the design and the development of a multichannel, portable and cost-effective SMU platform for the continuous and long-term characterization of OECT biosensors. The hardware is based on an electronic board interfacing via customized connection to a six-OECT set-up, integrated in a standard culture plate and operated within a cell incubator. System functionality is managed by Arduino Nano microcontroller through ad-hoc software, enabling automated characterization of the OECTs. The platform characterization performance is evaluated by comparing the I – V characteristics and transient responses of the tested OECTs with those obtained by the commercial Keysight B2912A SMU. Long-term and continuous operation is verified by a 30 minutes-sampling, five days measurement. The assessed features of the platform and the achieved results suggest that the proposed prototype is more appropriate than conventional SMUs for OECT-based in-vitro biosensing. The presented solution has the potential to support biological research by offering an operator-independent and in-vitro compatible apparatus.

15 October 2026 in Sensors
Verified
Journal Article
Open access
PDF file
MCMichele Campanini
Michele Campanini
LVLorenzo Vigna
Lorenzo Vigna
DVDavide Vurro
Davide Vurro
Pasquale D'AngeloPasquale D'Angelo
Pasquale D'Angelo
MCMartina Cicolini
Martina Cicolini
ABAlberto Ballesio
Alberto Ballesio
Organic Electrochemical Transistors (OECTs) have emerged as continuous monitoring sensors for in vitro models. Source Measure Units (SMUs) are typical instruments used to simultaneously control input and output signals in OECTs. Conventional SMUs are unsuitable for in vitro applications due to their limited channel count, large footprint and high cost. This work presents the design and development of a multichannel, portable and cost-effective SMU platform for the continuous and long-term characterization of OECT biosensors. The hardware is based on a breadboard interfacing via custom connections to a six-OECT setup integrated into a standard culture plate and operated within a cell incubator. System functionality is managed by an Arduino Nano microcontroller (Arduino, Monza, Italy) through custom-developed software, enabling automated characterization of the OECTs. Platform performance was evaluated by comparing OECT I–V characteristics and time responses against the commercial B2912A SMU (Keysight Technologies, Santa Rosa, CA, USA), using phosphate-buffered saline (PBS) to mimic biological samples. Long-term continuous operation was verified through a 5 day recording session with a 30 min sampling interval. Experimental results demonstrated consistent functionality with satisfactory accuracy for the targeted application. The proposed platform is a promising alternative to conventional SMUs for the continuous and long-term monitoring of OECT biosensors. Future work will focus on hardware optimization and full biological validation through OECT-based monitoring of in vitro models.