Lorenzo Vigna

Dr. Lorenzo Vigna

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
LVLorenzo Vigna
Lorenzo Vigna
AVAlessio Verna
Alessio Verna
SMSimone Luigi Marasso
Simone Luigi Marasso
MSM. Sangermano
M. Sangermano
PDP. D’angelo
P. D’angelo
MCMatteo Cocuzza
Matteo Cocuzza

29 July 2021 in ACS Omega
Verified
Journal Article
Open access
LVLorenzo Vigna
Lorenzo Vigna
ANArianna Nigro
Arianna Nigro
AVAlessio Verna
Alessio Verna
IFIvan Vito Ferrari
Ivan Vito Ferrari
SMSimone Luigi Marasso
Simone Luigi Marasso
MCMatteo Cocuzza
Matteo Cocuzza
Miniaturized low-cost sensors for volatile organic compounds (VOCs) have the potentiality to become a fundamental tool for indoor and outdoor air quality monitoring, to significantly improve everyday life. Layered double hydroxides (LDHs) belong to the class of anionic clays and are largely employed for NOx detection, while few results are reported on VOCs. In this work, a novel LDH coprecipitation method is proposed. For the first time, a study comparing four LDHs (ZnAl–Cl, ZnFe–Cl, ZnAl–NO3, and MgAl–NO3) is carried out to investigate the sensing performances. As explored through several microscopy and spectroscopy analyses, LDHs show a morphology characterized by a large surface area and a three-dimensional hierarchical flowerlike architecture with micro- and nanopores that induce a fast diffusion and highly effective surface interaction of the target gases. The fabricated sensors, operating at room temperature, are able to reversibly and selectively detect acetone, ethanol, ammonia, and chlorine vapors, reaching significant sensing response values up to 6% at 21 °C. The results demonstrate that by changing the LDHs’ composition, it is possible to modulate the sensitivity and selectivity of the sensor, helping the discrimination of different analytes, and the consequent integration on a sensor array paves the way for electronic nose development.

17 October 2018 in Macromolecular Materials and Engineering
Verified
Journal Article
Closed access
PDF file
LVLorenzo Vigna
Lorenzo Vigna
AFAndrea Fasoli
Andrea Fasoli
MCMatteo Cocuzza
Matteo Cocuzza
FPFabrizio C. Pirri
Fabrizio C. Pirri
LBLuisa D. Bozano
Luisa D. Bozano
Marco SangermanoMarco Sangermano
Marco Sangermano

30 September 2025 in ACS Sensors
Verified
Journal Article
Open access
MCMartina Cicolini
Martina Cicolini
ASAli Solgi
Ali Solgi
LVLorenzo Vigna
Lorenzo Vigna
ABAlberto Ballesio
Alberto Ballesio
SMSimone Luigi Marasso
Simone Luigi Marasso
LNLucia Napione
Lucia Napione
Paper-based biosensors hold significant promise for point-of-care (POC) diagnostic applications. Among these, lateral flow assays (LFAs) are particularly appealing due to their ease of use, portability, and low cost. However, their limited sensitivity and qualitative output set drawbacks on their reliability and widespread application. In response to the growing need for rapid and consistent diagnostic and monitoring tools, Organic Electrochemical Transistors (OECTs) have emerged as powerful devices in biochemical sensing applications because of their high sensitivity, low operating voltage, and compatibility with a biological environment. In this work, we developed a printable OECT for biochemical sensing on a commercial cellulose membrane, commonly used as a detection substrate in LFA-based rapid tests. Constituting a self-standing, passive microfluidic platform, the system was designed to transport and interact with liquid samples, while ensuring a contamination-free zone for the active components. Inside a dry area delimited by a hydrophobic barrier, the OECT components include dispense-printed silver electrodes, a polystyrenesulfonate-doped poly(3,4-ethylenedioxy-thiophene) (PEDOT:PSS) channel and gate, and a solid-state electrolyte (SSE) layer. Outside the dry area, a PEDOT:PSS extended gate alone interacts with the analyte in the liquid sample, preventing channel contamination and enhancing the system stability. We investigated the effect of dopamine (DA) oxidation at the extended gate interface on the device response and observed variations in the transfer characteristics, transconductance and Ion/Ioff ratio, obtaining a limit of detection of 0.01 mM. With a maximum transconductance of approximately 4 mS, our system shows potential for the integration of an easy-to-fabricate device into an affordable biochemical assay, providing quantitative results at the point-of-care site to complement and reinforce the typical colorimetric response of LFAs.

30 July 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
MCMichele Campanini
Michele Campanini
LVLorenzo Vigna
Lorenzo Vigna
DVDavide Vurro
Davide Vurro
Pasquale D'AngeloPasquale D'Angelo
Pasquale D'Angelo
MCMartina Cicolini
Martina Cicolini
ABAlberto Ballesio
Alberto Ballesio
Organic Electrochemical Transistors (OECTs) have emerged as continuous monitoring sensors for in-vitro models. Source and Measure Units (SMUs) are typical instruments used to simultaneously control input and output signals on OECTs. Conventional SMUs are unsuitable for in-vitro application due to their limited channels count, large footprint and high cost. This work presents the design and the development of a multichannel, portable and cost-effective SMU platform for the continuous and long-term characterization of OECT biosensors. The hardware is based on an electronic board interfacing via customized connection to a six-OECT set-up, integrated in a standard culture plate and operated within a cell incubator. System functionality is managed by Arduino Nano microcontroller through ad-hoc software, enabling automated characterization of the OECTs. The platform characterization performance is evaluated by comparing the I – V characteristics and transient responses of the tested OECTs with those obtained by the commercial Keysight B2912A SMU. Long-term and continuous operation is verified by a 30 minutes-sampling, five days measurement. The assessed features of the platform and the achieved results suggest that the proposed prototype is more appropriate than conventional SMUs for OECT-based in-vitro biosensing. The presented solution has the potential to support biological research by offering an operator-independent and in-vitro compatible apparatus.

12 September 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
GCGiuseppe Cavuoto
Giuseppe Cavuoto
DPDiego Pugliese
Diego Pugliese
VDVincenzo Della Donna
Vincenzo Della Donna
AVAlessio Verna
Alessio Verna
AFAlessio Facello
Alessio Facello
SMSimone Luigi Marasso
Simone Luigi Marasso
Micro-Coriolis mass flow sensors offer a promising approach for the measurement of low flow rates and fluid density, but conventional silicon-based implementations often require complex and costly fabrication processes. In this work, we present the development and experimental characterization of a fully polymeric MEMS (Micro Electro Mechanical Systems) Coriolis microsensor fabricated using SU-8 100. The device consists of a suspended Ω-shaped microfluidic channel enclosed between two independently fabricated SU-8 layers and assembled by thermocompression bonding under vacuum condition. A maskless laser direct writing process was adopted to enable rapid optimization of the device geometry and fabrication parameters. Particular attention was devoted to the optimization of the bonding process, for which a temperature range from (125 to 135) ◦C, an applied load from (320 to 400) N, and a bonding time of 2 min were identified as the most suitable conditions, providing reliable sealing while preserving the microchannel geometry. The fabricated devices exhibited leak-tight operation up to approximately 1200 mbar and enabled flow rates of up to 200 µL/min. The dynamic response of the microsensor was subsequently investigated by measuring the resonance frequency of the suspended microchannel for fluids with different densities. A quadratic calibration model based on the frequency shift relative to the air-filled condition was established over a density range between (0.78 and 1.07) g/cm3. The resulting density measurements exhibited an expanded relative uncertainty of 1.21 % (k = 2). Independent validation using ethanol, n-nonane, APN26, and APN415 yielded deviations between -0.31 % and 0.20 % from the corresponding reference densities. These results demonstrate the feasibility of SU-8-based MEMS technology for integrated fluid-density sensing and provide a pave the way for the further development of low-cost polymeric micro-Coriolis devices for microfluidic and metrological applications.