Klaas Kunze

Dr. Klaas Kunze

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2022 in Composite Structures
Verified
Journal Article
Closed access
RWR.A.J. Weerts
R.A.J. Weerts
OCO. Cousigné
O. Cousigné
KKKlaas Kunze
Klaas Kunze
MGM.G.D. Geers
M.G.D. Geers
JRJ.J.C. Remmers
J.J.C. Remmers

24 November 2021 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
KÖKutlu A. Öztas
Kutlu A. Öztas
KKKlaas Kunze
Klaas Kunze
KJKumar Jois
Kumar Jois
JSJohannes Sackmann
Johannes Sackmann
SZSwen Zaremba
Swen Zaremba
MRMichael G. Ruf
Michael G. Ruf

10 June 2021
Verified
Book Chapter
Closed access
PDF file
HBHenning Baumgarten
Henning Baumgarten
MBMarius Böhmer
Marius Böhmer
MHMichael Hinz
Michael Hinz
MNMartin Nijs
Martin Nijs
SPStefan Pischinger
Stefan Pischinger
HEHelmut Eichlseder
Helmut Eichlseder

15 September 2016
Verified
Book Chapter
Closed access
PDF file
ABAndreas Bootz
Andreas Bootz
SGSteffen Gruber
Steffen Gruber
JHJens Holtschulze
Jens Holtschulze
HKHugo Kroiss
Hugo Kroiss
KKKlaas Kunze
Klaas Kunze
HVHeiner Volk
Heiner Volk

1 November 2026 in Hydrogen
Verified
Journal Article
Open access
PDF file
KSKilian Stengel
Kilian Stengel
KKKlaas Kunze
Klaas Kunze
HHHolger Hoche
Holger Hoche
MOMatthias Oechsner
Matthias Oechsner
In pressurized hydrogen vessels, barrier coatings on steel are exposed to hydrogen and biaxial tensile stress simultaneously. This study investigates the hydrogen permeation behavior of uncoated and electroplated copper-coated DC01 sheets under static elastic biaxial tension with the hoop-to-axial stress ratio of a 700 bar Type I pressure vessel. Electrochemical permeation measurements according to ISO 17081 were performed on 0.2 mm thick DC01 specimens using a Devanathan–Stachurski cell. A cross-tension specimen and a dedicated loading device superimposed the biaxial stress during permeation testing. For uncoated specimens, biaxial stress tended to decrease the mean effective diffusion coefficient by 34% and to increase the steady-state permeation flux by about 5%, although not statistically significant for three specimens per condition. A repeated measurement after unloading indicated reversibility. In the unstressed state, no permeation transient was detected through a 5 µm electroplated copper layer. Under biaxial tensile stress, however, the copper-coated specimens showed a measurable permeation signal, with a permeation reduction factor of 230 and an apparent coating diffusion coefficient of 4.94 × 10−14 m2 s−1. The results show that elastic biaxial stress markedly reduces the barrier effectiveness of the electroplated copper coating, whereas its effect on substrate permeation is small.