Alberto Mazzi

Dr. Alberto Mazzi

Fondazione Bruno Kessler (FBK), Center for Material and Microsystems (CMM), Via Sommarive, 18, I-38123 Trento, Italy
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
AGAlberto Gola
Alberto Gola
Fabio AcerbiFabio Acerbi
Fabio Acerbi
MCMassimo Capasso
Massimo Capasso
MMMarco Marcante
Marco Marcante
AMAlberto Mazzi
Alberto Mazzi
NZNicola Zorzi
Nicola Zorzi
Different applications require different customizations of silicon photomultiplier (SiPM) technology. We present a review on the latest SiPM technologies developed at Fondazione Bruno Kessler (FBK, Trento), characterized by a peak detection efficiency in the near-UV and customized according to the needs of different applications. Original near-UV sensitive, high-density SiPMs (NUV-HD), optimized for Positron Emission Tomography (PET) application, feature peak photon detection efficiency (PDE) of 63% at 420 nm with a 35 um cell size and a dark count rate (DCR) of 100 kHz/mm2. Correlated noise probability is around 25% at a PDE of 50% at 420 nm. It provides a coincidence resolving time (CRT) of 100 ps FWHM (full width at half maximum) in the detection of 511 keV photons, when used for the readout of LYSO(Ce) scintillator (Cerium-doped lutetium-yttrium oxyorthosilicate) and down to 75 ps FWHM with LSO(Ce:Ca) scintillator (Cerium and Calcium-doped lutetium oxyorthosilicate). Starting from this technology, we developed three variants, optimized according to different sets of specifications. NUV-HD–LowCT features a 60% reduction of direct crosstalk probability, for applications such as Cherenkov telescope array (CTA). NUV-HD–Cryo was optimized for cryogenic operation and for large photosensitive areas. The reference application, in this case, is the readout of liquid, noble-gases scintillators, such as liquid Argon. Measurements at 77 K showed a remarkably low value of the DCR of a few mHz/mm2. Finally, vacuum-UV (VUV)-HD features an increased sensitivity to VUV light, aiming at direct detection of photons below 200 nm. PDE in excess of 20% at 175 nm was measured in liquid Xenon. In the paper, we discuss the specifications on the SiPM related to different types of applications, the SiPM design challenges and process optimizations, and the results from the experimental characterization of the different, NUV-sensitive technologies developed at FBK.

4 June 2021 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
SGStefan Gundacker
Stefan Gundacker
RPRosalinde Pots
Rosalinde Pots
ANAlexander Nepomnyashchikh
Alexander Nepomnyashchikh
ERE Radzhabov
E Radzhabov
RSRoman Shendrik
Roman Shendrik
EAEtiennette Auffray
Etiennette Auffray
Inorganic scintillators are widely used for fast timing applications in high-energy physics (HEP) experiments, time-of-flight positron emission tomography and time tagging of soft and hard x-ray photons at advanced light sources. As the best coincidence time resolution (CTR) achievable is proportional to the square root of the scintillation decay time it is worth studying fast cross-luminescence, for example in BaF 2 which has an intrinsic yield of about 1400 photons/MeV. However, emission bands in BaF 2 are located in the deep-UV at 195 nm and 220 nm, which sets severe constraints on photodetector selection. Recent developments in dark matter and neutrinoless double beta decay searches have led to silicon photomultipliers (SiPMs) with photon detection efficiencies of 20%–25% at wavelengths of 200 nm. We tested state-of-the-art devices from Fondazione Bruno Kessler and measured a best CTR of 51 ± 5 ps full width at half maximum when coupling 2 mm × 2 mm × 3 mm BaF 2 crystals excited by 511 keV electron–positron annihilation gammas. Using these vacuum ultraviolet SiPMs we recorded the scintillation kinetics of samples from Epic Crystal under 511 keV excitation, confirming a fast decay time of 855 ps with 12.2% relative light yield and 805 ns with 84.0% abundance, together with a smaller rise time of 4 ps beyond the resolution of our setup. The total intrinsic light yield was determined to be 8500 photons/MeV. We also revealed a faster component with 136 ps decay time and 3.7% light yield contribution, which is extremely interesting for the fastest timing applications. Timing characteristics and CTR results on BaF 2 samples from different producers and with different dopants (yttrium, cadmium and lanthanum) are given, and clearly show that the the slow 800 ns emission can be effectively suppressed. Such results ultimately pave the way for high-rate ultrafast timing applications in medical diagnosis, range monitoring in proton or heavy ion therapy and HEP.

12 February 2019 in Instruments
Verified
Journal Article
Open access
PDF file
Fabio AcerbiFabio Acerbi
Fabio Acerbi
GPGiovanni Paternoster
Giovanni Paternoster
MCMassimo Capasso
Massimo Capasso
MMMarco Marcante
Marco Marcante
AMAlberto Mazzi
Alberto Mazzi
AGAlberto Gola
Alberto Gola
Silicon photomultipliers (SiPMs) are single-photon sensitive solid-state detectors that are becoming popular for several applications, thanks to massive performance improvements over the last years. Starting as a replacement for the photomultiplier tube (PMT), they are now used in medical applications, big high-energy physics experiments, nuclear physics experiments, spectroscopy, biology and light detection and ranging (LIDAR) applications. Due to different requirements in terms of detection efficiency, noise, etc., several optimizations have been introduced by the manufacturers; for example, spectral sensitivity has been optimized for visible light, near ultraviolet, vacuum ultraviolet, and near infrared light. Each one of them require specific processes and structural optimization. We present in this paper recent improvements in SiPM performance, owing to a higher cell fill-factor, lower noise, improved silicon materials, and deep trench isolation. We describe issues related to the characterization of analog SiPM, particularly due to the different sources of correlated noise, which have to be distinguished from each other and from the primary pulses. We also describe particular analyses and optimizations conducted for specific applications like the readout of liquid noble gas scintillators, requiring these detectors to operate at cryogenic temperatures.

1 February 2020 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
CAC.E. Aalseth
C.E. Aalseth
SAS. Abdelhakim
S. Abdelhakim
FAF. Acerbi
F. Acerbi
PAP. Agnes
P. Agnes
RAR. Ajaj
R. Ajaj
GZG. Zuzel
G. Zuzel

30 May 2019 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
GTG. Tamulaitis
G. Tamulaitis
AVAndrey Vasil'ev
Andrey Vasil'ev
MKM. Korzhik
M. Korzhik
AMAlberto Mazzi
Alberto Mazzi
AGAlberto Gola
Alberto Gola
DKD. Kozlov
D. Kozlov

1 October 2016 in Electrochimica Acta
Verified
Journal Article
Closed access
Michele OrlandiMichele Orlandi
Michele Orlandi
AMAlberto Mazzi
Alberto Mazzi
GAGiacomo Arban
Giacomo Arban
NBNicola Bazzanella
Nicola Bazzanella
PRPaolo Rudatis
Paolo Rudatis
AMAntonio Miotello
Antonio Miotello