Georgios E. Karpetas

Dr. Georgios E. Karpetas

University of Thessaly, Larissa, Greece
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2017 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
GKGeorgios E. Karpetas
Georgios E. Karpetas
Christos MichailChristos Michail
Christos Michail
George FountosGeorge Fountos
George Fountos
NKNektarios I. Kalyvas
Nektarios I. Kalyvas
IVIoannis G. Valais
Ioannis G. Valais
GPGeorge S. Panayiotakis
George S. Panayiotakis

4 July 2019 in Crystals
Verified
Journal Article
Open access
PDF file
GSGeorge Saatsakis
George Saatsakis
NKNektarios Kalyvas
Nektarios Kalyvas
Christos MichailChristos Michail
Christos Michail
KNKonstantinos Ninos
Konstantinos Ninos
ABATHANASIOS Dimitrios BAKAS
ATHANASIOS Dimitrios BAKAS
GPGeorge Panayiotakis
George Panayiotakis
The aim of this article is to evaluate optical characteristics, such as the intrinsic conversion efficiency and the inherent light propagation efficiency of three polymethyl methacrylate (PMMA)/methyl methacrylate (MMA) composite ZnCuInS/ZnS (core/shell) nanocrystal flexible films. The concentrations of these were 100 mg/mL, 150 mg/mL, and 250 mg/mL, respectively. Composite films were prepared by homogeneously diluting dry powder quantum dot (QD) samples in toluene and subsequently mixing these with a PMMA/MMA polymer solution. The absolute luminescence efficiency (AE) of the films was measured using X-ray excitation. A theoretical model describing the optical photon propagation in scintillator materials was used to calculate the fraction of the generated optical photons passed through the different material layers. Finally, the intrinsic conversion efficiency was calculated by considering the QD quantum yield and the optical photon emission spectrum.

1 July 2021 in Annals of Emerging Technologies in Computing
Verified
Journal Article
Open access
PDF file
NCNikolaos Chatzisavvas
Nikolaos Chatzisavvas
GPGeorgios Priniotakis
Georgios Priniotakis
MPMichael Papoutsidakis
Michael Papoutsidakis
DNDimitrios Nikolopoulos
Dimitrios Nikolopoulos
IVIoannis Valais
Ioannis Valais
GKGeorgios E. Karpetas
Georgios E. Karpetas
The fast developments and ongoing demands in radiation dosimetry have piqued the attention of many software developers and physicists to create powerful tools to make their experiments more exact, less expensive, more focused, and with a wider range of possibilities. Many software toolkits, packages, and programs have been produced in recent years, with the majority of them available as open source, open access, or closed source. This study is mostly focused to present what are the Monte Carlo software developed over the years, their implementation in radiation treatment, radiation dosimetry, nuclear detector design for diagnostic imaging, radiation shielding design and radiation protection. Ten software toolkits are introduced, a table with main characteristics and information is presented in order to make someone entering the field of computational Physics with Monte Carlo, make a decision of which software to use for their experimental needs. The possibilities that this software can provide us with allow us to design anything from an X-Ray Tube to whole LINAC costly systems with readily changeable features. From basic x-ray and pair detectors to whole PET, SPECT, CT systems which can be evaluated, validated and configured in order to test new ideas. Calculating doses in patients allows us to quickly acquire, from dosimetry estimates with various sources and isotopes, in various materials, to actual radiation therapies such as Brachytherapy and Proton therapy. We can also manage and simulate Treatment Planning Systems with a variety of characteristics and develop a highly exact approach that actual patients will find useful and enlightening. Shielding is an important feature not only to protect people from radiation in places like nuclear power plants, nuclear medical imaging, and CT and X-Ray examination rooms, but also to prepare and safeguard humanity for interstellar travel and space station missions. This research looks at the computational software that has been available in many applications up to now, with an emphasis on Radiation Dosimetry and its relevance in today's environment.

23 December 2021 in Nutrients
Verified
Journal Article
Open access
PDF file
ΛΚΛαμπρινή Κοντοπούλου
Λαμπρινή Κοντοπούλου
GKGeorgios E. Karpetas
Georgios E. Karpetas
Evangelos FradelosEvangelos Fradelos
Evangelos Fradelos
Ioanna V. PapathanasiouIoanna V. Papathanasiou
Ioanna V. Papathanasiou
Foteini MalliFoteini Malli
Foteini Malli
Konstantinos I. GourgoulianisKonstantinos I. Gourgoulianis
Konstantinos I. Gourgoulianis
According to the WHO, front-of-pack nutrition labeling provides simplified nutrition information in the form of symbols, colors or words that can help consumers understand the nutritional quality of food, thus leading them to healthier food choices. It is considered of the utmost importance to explore the knowledge and understanding of consumers about this form of nutrition labeling. The aim of this study was to investigate the understanding and perceptions of Greek consumers in response to five different front-of-pack nutrition labels (FoPLs): the Multiple Traffic Lights, Health Star Rating System, Guideline Daily Amounts, Warning Symbols and Nutri-Score. From April 2021 to June 2021, 1278 participants from Greece took part in an online survey where they were asked to rank three products according to their nutritional quality. The classification process was performed first without FoPLs and then with FoPLs. The ability to classify products according to their nutritional quality was evaluated with multinomial logistic regression models, and the Nutri-Score label presented greater improvements when compared to the GDA label for Greek consumers. The Nutri-Score seemed to better help the Greek consumers rank foods according to their nutritional value.

9 December 2018 in Crystals
Verified
Journal Article
Open access
PDF file
Christos MichailChristos Michail
Christos Michail
GKGeorgios E. Karpetas
Georgios E. Karpetas
NKNektarios Kalyvas
Nektarios Kalyvas
Ioannis ValaisIoannis Valais
Ioannis Valais
IKIoannis Kandarakis
Ioannis Kandarakis
George FountosGeorge Fountos
George Fountos
Background: The aim of the present study was to assess the upper information content bound of positron emission tomography (PET) images, by means of the information capacity (IC). Methods: The Geant4 Application for the Tomographic Emission (GATE) Monte Carlo (MC) package was used, and reconstructed images were obtained by using the software for tomographic image reconstruction (STIR). The case study for the assessment of the information content was the General Electric (GE) Discovery-ST PET scanner. A thin-film plane source aluminum (Al) foil, coated with a thin layer of silica and with a 18F-fludeoxyglucose (FDG) bath distribution of 1 MBq was used. The influence of the (a) maximum likelihood estimation-ordered subsets-maximum a posteriori probability-one step late (MLE-OS-MAP-OSL) algorithm, using various subsets (1 to 21) and iterations (1 to 20) and (b) different scintillating crystals on PET scanner’s performance, was examined. The study was focused on the noise equivalent quanta (NEQ) and on the single index IC. Images of configurations by using different crystals were obtained after the commonly used 2-dimensional filtered back projection (FBP2D), 3-dimensional filtered back projection re-projection (FPB3DRP) and the (MLE)-OS-MAP-OSL algorithms. Results: Results shown that the images obtained with one subset and various iterations provided maximum NEQ values, however with a steep drop-off after 0.045 cycles/mm. The single index IC data were maximized for the range of 8–20 iterations and three subsets. The PET scanner configuration incorporating lutetium orthoaluminate perovskite (LuAP) crystals provided the highest NEQ values in 2D FBP for spatial frequencies higher than 0.028 cycles/mm. Bismuth germanium oxide (BGO) shows clear dominance against all other examined crystals across the spatial frequency range, in both 3D FBP and OS-MAP-OSL. The particular PET scanner provided optimum IC values using FBP3DRP and BGO crystals (2.4829 bits/mm2). Conclusions: The upper bound of the image information content of PET scanners can be fully characterized and further improved by investigating the imaging chain components through MC methods.

1 September 2014 in Nuclear Medicine Communications
Verified
Journal Article
Closed access
GKGeorgios E. Karpetas
Georgios E. Karpetas
Christos MichailChristos Michail
Christos Michail
GFGeorge P. Fountos
George P. Fountos
IKIoannis S. Kandarakis
Ioannis S. Kandarakis
GPGeorge S. Panayiotakis
George S. Panayiotakis
Objective The aim of this study was to propose a novel method for image quality assessment in PET scanners through estimation of the modulation transfer function (MTF) of a plane source. The simulation was implemented using the previously validated Monte-Carlo model. A comparison of the proposed method with the more traditional technique, based on a line source, was also performed. Materials and methods The Geant4 application for tomographic emission (GATE) Monte-Carlo package was used for model development, and reconstructed images were obtained using software for tomographic image reconstruction (STIR) with cluster computing. A novel plane source consisting of a radioactive (18F-fluorodeoxyglucose) thin-layer chromatography plate was simulated (total source activity: 44.4 MBq) to assess image quality through the MTF. All images were reconstructed with the three-dimensional filtered back projection (FBP3DRP) and ordered-subsets expectation maximization (OSEM) reprojection algorithms. Results The MTFs obtained using ordered-subsets expectation maximization show, in all cases, that higher frequencies are preserved compared with those obtained using the FBP3DRP. In addition, the plane source method is less prone to noise than the conventional line source method (SD=0.0031 and 0.0203, respectively). Conclusion The thin-layer chromatography-based plane source presented requires materials commonly found in a clinical environment and could be used to assess image quality in nuclear medicine departments and to further develop PET and single-photon emission computed tomography scanners through Monte-Carlo simulations.