George Fountos

Prof. Dr. George Fountos

University of West Attica, Athens, Greece

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2015 in Physica Medica
Verified
Journal Article
Closed access
PSP. Sotiropoulou
P. Sotiropoulou
George FountosGeorge Fountos
George Fountos
NMN. Martini
N. Martini
VKV. Koukou
V. Koukou
Christos MichailChristos Michail
Christos Michail
GNG. Nikiforidis
G. Nikiforidis

27 May 2020 in Crystals
Verified
Journal Article
Open access
PDF file
Christos MichailChristos Michail
Christos Michail
VKVaia Koukou
Vaia Koukou
NMNiki Martini
Niki Martini
GSGeorge Saatsakis
George Saatsakis
NKNektarios Kalyvas
Nektarios Kalyvas
Ioannis ValaisIoannis Valais
Ioannis Valais
Background: In this study, the light output of a cadmium tungstate (CdWO4) single crystal was measured under various X-ray radiographic energies. Methods: A CdWO4 single crystal (10 × 10 × 10 mm3) was exposed to X-rays in the 50–130 kVp range. Measurements were evaluated against published data for single crystals of equal dimensions (CaF2:Eu and Lu3Al5O12:Ce). Since the crystal was examined for application in medical imaging detectors, the emitted optical spectrum was classified with respect to the spectral compatibility of numerous commercial optical sensors. Results: The luminescence efficiency (LE) was found to constantly increase with X-ray energy and was higher than that of CaF2:Eu for energies above 90 kVp. However, the efficiency of the previously published Lu3Al5O12:Ce was found to be constantly higher than that of CdWO4. The light emitted from CdWO4 can be optimally detected by certain charge-coupled devices (CCDs), amorphous silicon photodiodes, and photocathodes. Conclusions: The high density (7.9 g/cm3) of CdWO4 and the luminescence signal of this material make it suitable for medical imaging (such as dual energy), high-energy physics or for applications of scintillators in harsh environments.

7 February 2024 in Crystals
Verified
Journal Article
Open access
PDF file
Christos MichailChristos Michail
Christos Michail
PLPanagiotis Liaparinos
Panagiotis Liaparinos
NKNektarios Kalyvas
Nektarios Kalyvas
Ioannis KandarakisIoannis Kandarakis
Ioannis Kandarakis
George FountosGeorge Fountos
George Fountos
Ioannis ValaisIoannis Valais
Ioannis Valais
Medical imaging instrumentation is mostly based on the use of luminescent materials coupled to optical sensors. These materials are employed in the form of granular screens, structured crystals, single transparent crystals, ceramics, etc. Storage phosphors are also incorporated in particular X-ray imaging systems. The physical properties of these materials should match the criteria required by the detective systems employed in morphological and functional biomedical imaging. The systems are analyzed based on theoretical frameworks emanating from the linear cascaded systems theory as well as the signal detection theory. Optical diffusion has been studied by different methodological approaches, such as experimental measurements and analytical modeling, including geometrical optics and Monte Carlo simulation. Analysis of detector imaging performance is based on image quality metrics, such as the luminescence emission efficiency (LE), the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE). Scintillators and phosphors may present total energy conversion on the order of 0.001–0.013 with corresponding DQE in the range of 0.1–0.6. Thus, the signal-to-noise ratio, which is crucial for medical diagnosis, shows clearly higher values than those of the energy conversion.

13 February 2021 in Materials
Verified
Journal Article
Open access
PDF file
DLDionysios Linardatos
Dionysios Linardatos
VKVaia Koukou
Vaia Koukou
NMNiki Martini
Niki Martini
AKAnastasios Konstantinidis
Anastasios Konstantinidis
ABATHANASIOS Dimitrios BAKAS
ATHANASIOS Dimitrios BAKAS
Christos MichailChristos Michail
Christos Michail
Certain imaging performance metrics are examined for a state-of-the-art 20 μm pixel pitch CMOS sensor (RadEye HR), coupled to a Gd2O2S:Tb scintillator screen. The signal transfer property (STP), the modulation transfer function (MTF), the normalized noise power spectrum (NNPS) and the detective quantum efficiency (DQE) were estimated according to the IEC 62220-1-1:2015 standard. The detector exhibits excellent linearity (coefficient of determination of the STP linear regression fit, R2 was 0.9978), while its DQE peaks at 33% and reaches 10% at a spatial frequency of 3 cycles/mm, for the measured with a Piranha RTI dosimeter (coefficient of variation CV = 0.03%) exposure value of 28.1 μGy DAK (detector Air Kerma). The resolution capabilities of the X-ray detector under investigation were compared to other commercial CMOS sensors, and were found in every case higher, except from the previous RadEye HR model (CMOS—Gd2O2S:Tb screen pair with 22.5 μm pixel pitch) version which had slightly better MTF. The present digital imager is designed for industrial inspection applications, nonetheless its applicability to medical imaging, as well as dual-energy is considered and certain approaches are discussed in this respect.

26 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Christos MichailChristos Michail
Christos Michail
PLPanagiotis Liaparinos
Panagiotis Liaparinos
NKNektarios Kalyvas
Nektarios Kalyvas
Ioannis KandarakisIoannis Kandarakis
Ioannis Kandarakis
George FountosGeorge Fountos
George Fountos
Ioannis ValaisIoannis Valais
Ioannis Valais
Medical imaging instrumentation design and construction is based on radiation sources and radiation detectors/sensors. This review focuses on the detectors and sensors of medical imaging systems. These systems are subdivided into various categories depending on their structure, the type of radiation they capture, how the radiation is measured, how the images are formed, and the medical goals they serve. Related to medical goals, detectors fall into two major areas: (i) anatomical imaging, which mainly concerns the techniques of diagnostic radiology, and (ii) functional-molecular imaging, which mainly concerns nuclear medicine. An important parameter in the evaluation of the detectors is the combination of the quality of the diagnostic result they offer and the burden of the patient with radiation dose. The latter has to be minimized; thus, the input signal (radiation photon flux) must be kept at low levels. For this reason, the detective quantum efficiency (DQE), expressing signal-to-noise ratio transfer through an imaging system, is of primary importance. In diagnostic radiology, image quality is better than in nuclear medicine; however, in most cases, the dose is higher. On the other hand, nuclear medicine focuses on the detection of functional findings and not on the accurate spatial determination of anatomical data. Detectors are integrated into projection or tomographic imaging systems and are based on the use of scintillators with optical sensors, photoconductors, or semiconductors. Analysis and modeling of such systems can be performed employing theoretical models developed in the framework of cascaded linear systems analysis (LCSA), as well as within the signal detection theory (SDT) and information theory.

15 September 2017 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
NMN Martini
N Martini
VKV Koukou
V Koukou
George FountosGeorge Fountos
George Fountos
Christos MichailChristos Michail
Christos Michail
ABATHANASIOS Dimitrios BAKAS
ATHANASIOS Dimitrios BAKAS
GNG Nikiforidis
G Nikiforidis
Calcifications are products of mineralization whose presence is usually associated with pathological conditions. The minerals mostly seen in several diseases are calcium oxalate (CaC 2 O 4 ), calcium carbonate (CaCO 3 ) and hydroxyapatite (HAp). Up to date, there is no in vivo method that could discriminate between minerals. To this aim, a dual energy x-ray method was developed in the present study. An analytical model was implemented for the determination of the Calcium/Phosphorus mass ratio ( m C a / m P ). The simulation was carried out using monoenergetic and polyenergetic x-rays and various calcification thicknesses (100–1000 μ m ) and types (CaC 2 O 4 , CaCO 3 , HAp). The experimental evaluation of the method was performed using the optimized irradiation conditions obtained from the simulation study. X-ray tubes, combined with energy dispersive and energy integrating (imaging) detectors, were used for the determination of the m C a / m P in phantoms of different mineral types and thicknesses. Based on the results of the experimental procedure, statistical significant difference was observed between the different types of minerals when calcification thicknesses were 300 μ m or higher.