Zhixuan Su

Dr. Zhixuan Su


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2024 in Materials
Verified
Journal Article
Open access
PDF file
ZHZhenyin Hai
Zhenyin Hai
ZSZhixuan Su
Zhixuan Su
RLRui Liang
Rui Liang
MGMaocheng Guo
Maocheng Guo
HZHongtian Zhu
Hongtian Zhu
CXChenyang Xue
Chenyang Xue
Pressure sensors prepared from sapphire exhibit excellent characteristics, including high-temperature resistance, high hardness, and resistance to electromagnetic interference. A Fast Fourier Transform and Mean Square Error (FFT-MSE) demodulation algorithm was employed to demodulate a sapphire sandwich-structure Fabry–Perot (F-P) pressure sensor. Through simulation analysis, the experimental results indicated that the demodulation error of the air cavity length in the range of 206 μm to 216 μm was less than 0.0008%. Compared to single demodulation methods and combined demodulation methods based on FFT or Minimum Mean Square Error (MMSE), the method proposed in this work reduced the demodulation error by more than three times and increased accuracy by more than six times. The algorithm was utilized to demodulate the sapphire sandwich-structure F-P pressure sensor, and the test results indicated that the fitting error of the sensor was less than 0.025% within the pressure range of 0 MPa to 10 MPa. The repeatability error was less than 0.066%, the zero-point deviation was 1.26%, and the maximum stability deviation was 0.0063% per 30 min. The algorithm effectively demodulated the actual cavity length variation in the sapphire sandwich-structure F-P pressure sensor, providing a solution for the performance evaluation of the sapphire sandwich-structure F-P pressure sensor.

22 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
SCSheng Chen
Sheng Chen
ZSZhixuan Su
Zhixuan Su
MDMin Dai
Min Dai
CXChenyang Xue
Chenyang Xue
JTJiping Tao
Jiping Tao
ZHZhenyin Hai
Zhenyin Hai
In industrial measurement, temperature field measurement typically relies on thermocouples and spectroscopic techniques. These traditional methods often suffer from insufficient precision, resulting in prevalent low-resolution measurements in real thermal scenarios. To address this challenge, we propose a novel general super-resolution approach for temperature field measurement in various thermal scenarios, leveraging the low-resolution (LR) data obtained from sensor array technology. The method incorporates skip connections and multi-path learning, along with physical information loss, to enhance accuracy. To validate the effectiveness of the approach, simulations across three two-dimensional thermal scenarios are conducted: the heating process in silicon chips, the thermodynamic process of hot and cold water mixing, and the convective heat transfer phenomena involved in metal sheet dissipation under airflow. The results show that the learning model can accurately predict the HR temperature. The proposed approach offers a pathway for generating HR solutions, bypassing traditional time-consuming simulation processes while ensuring data accuracy. By utilizing a fixed model and a lightweight physical loss function, we simplify the deployment process, facilitating applications in computational fluid dynamics (CFD) solutions, engineering measurements, and related fields.

21 August 2025 in Sensors
Verified
Journal Article
Open access
PDF file
ZHZhenyin Hai
Zhenyin Hai
YCYue Chen
Yue Chen
ZSZhixuan Su
Zhixuan Su
HJHongwei Ji
Hongwei Ji
YZYihang Zhang
Yihang Zhang
Zhichun LiuZhichun Liu
Zhichun Liu
Aerospace engines and hypersonic vehicles, among other high-temperature components, often operate in environments characterized by temperatures exceeding 1000 °C and high-speed airflow impacts, resulting in severe thermal erosion conditions. Coaxial thermocouples (CTs), with their unique self-eroding characteristic, are particularly well suited for use in such extreme environments. However, fabricating high-temperature electrical insulation layers for coaxial thermocouples remains challenging. Inspired by the self-healing mechanism of pine trees, we designed a composite electrical insulation layer with a similar self-healing function. This composite layer exhibits excellent high-temperature insulation properties (insulation resistance of 14.5 kΩ at 1200 °C). Applied as the insulation layer in K-type coaxial thermocouples via dip-coating, the thermocouples were tested for temperature and heat flux. Temperature tests showed an accuracy of 1.72% in the range of 200–1200 °C, a drift rate better than 0.474%/h at 1200 °C, and hysteresis better than 0.246%. The temperature response time was 1.08 ms. Heat flux tests demonstrated a measurable range of 0–41.32 MW/m2 with an accuracy better than 6.511% and a heat flux response time of 7.6 ms. In simulated extreme environments, the K-type coaxial thermocouple withstood 70 s of 900 °C flame impact and 50 cycles of high-power laser thermal shock.

19 June 2025 in Materials
Verified
Journal Article
Open access
PDF file
ZHZhenyin Hai
Zhenyin Hai
YCYue Chen
Yue Chen
ZSZhixuan Su
Zhixuan Su
YWYemin Wang
Yemin Wang
SGShigui Gong
Shigui Gong
Zhichun LiuZhichun Liu
Zhichun Liu
Surface erosion of the coaxial thermocouple probe initiates continuous bridging of thermoelectric materials on the insulation layer surface, forming new temperature measurement junctions. This inherent ability to measure continuous self-erosion ensures the operational reliability of the coaxial thermocouples in high-temperature ablative environments. However, the fabrication of a high-temperature electrical insulation layer and a high-adhesion insulating layer in the coaxial thermocouples remains a challenge. Inspired by calcium carbonate/oxalate crystals in jujube leaves that strengthen the leaves, a bioinspired structural ceramic (BSC) mimicking these needle-like crystals is designed. This BSC demonstrates excellent high-temperature insulation (with insulation impedance of 2.55 kΩ at 1210 °C) and adhesion strength (35.3 Newtons). The BSC is successfully used as the insulating layer in a K-type coaxial thermocouple. The generation rules for surface junctions are systematically studied, revealing that stable and reliable measurement junctions can be created when the sandpaper grit does not exceed 600#. Static test results show that the K-type coaxial thermocouple ranges from 200 °C to 1200 °C with an accuracy of 1.1%, a drift rate better than 0.0137%/h, and hysteresis better than 0.81%. Dynamic test results show that the response time is 1.08 ms. The K-type coaxial thermocouple can withstand a high-temperature flame impact for 300 s at 1200 °C, as well as over forty cycles of high-power laser thermal shock, while maintaining good response characteristics. Therefore, the K-type coaxial thermocouple designed in this study provides an ideal solution for long-term temperature monitoring of the thermal components of aerospace engines under extremely high-temperature, high-speed, and strong thermal shock conditions.

20 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
ZZZewang Zhang
Zewang Zhang
SGShigui Gong
Shigui Gong
JYJiajie Ye
Jiajie Ye
CZChengfei Zhang
Chengfei Zhang
JCJun Chen
Jun Chen
ZHZhenyin Hai
Zhenyin Hai
Multi-point array thin-film thermocouples have strong potential for high-precision, wide-range temperature monitoring in applications such as aircraft engine thermal condition assessment and industrial process control. However, conventional single-point thin-film thermocouples cannot satisfy the distributed measurement requirements of large-area temperature fields, and the accuracy of multi-point arrays is often degraded by coupling effects among sensing nodes, which hinders their engineering deployment. In this work, a multi-point array thin-film thermocouple is fabricated via precision welding, and an insulating layer is deposited on the sensor surface using electrospray atomization to establish a multi-point temperature-sensing hardware system. To compensate for coupling-induced deviations, a deep learning–based calibration method is developed: measurements from the array and reference thermocouples are synchronously collected to build the dataset, outliers are removed using the interquartile range (IQR) method, and a three-hidden-layer multilayer perceptron (MLP) is trained for each node independently using the Adam optimizer (learning rate 0.001) with an 8:2 train–test split. Performance is quantified by MAE, MSE, and R2, and the results show that the proposed approach markedly reduces measurement errors and improves the accuracy of the array thermocouples, demonstrating reliable performance and practical applicability for precise large-area temperature-field monitoring.

25 June 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Zhichun LiuZhichun Liu
Zhichun Liu
FCFei Chen
Fei Chen
ZSZhixuan Su
Zhixuan Su
HWHeng Wang
Heng Wang
JSJinghan Si
Jinghan Si
ZHZhenyin Hai
Zhenyin Hai
High-temperature metallic surfaces in aero-engine hot sections and related thermal systems are subjected to MW/m2-level heat-flux loads and transient thermal conditions, creating a need for sensors capable of quantifying heat flux under high-temperature conditions. This study aims to develop a screen-printed Ag–AgPd thick-film thermopile heat-flux sensor (HFS) for MW/m2-level heat-flux measurement on high-temperature metallic surfaces. Its main feature is the integration of an Ag–AgPd thermopile sensing layer, an insulating layer, and a thermal-resistance layer on a SUS430 stainless-steel substrate through a screen-printing-based multilayer fabrication route. Microstructural characterization, annealing condition comparison, laser comparison calibration, repeated loading, dynamic-response testing, and flame-heating testing were conducted to evaluate the sensor structure and performance. Under laser comparison calibration, the sensor achieved a MW/m2-level calibrated heat-flux response over 0.32–1.37 MW/m2, with a near-linear output relationship of R2>0.998, a sensitivity of 2.67 μV/(kW/m2), a nonlinearity of 1.83%, a hysteresis error below 0.29%, a repeatability error below 0.43%, a sample-to-sample consistency error of 1.06%, a maximum accuracy-test deviation of 1.84%, and a maximum repeated-loading stability error of 1.33%. The sensor also exhibited a time constant of 0.806 s under laser step excitation, and the baseline-corrected equivalent heat-flux response remained stable during approximately 120 s of flame heating at about 800 °C. These results indicate that the proposed HFS provides a feasible thick-film thermopile sensing approach for MW/m2-level heat-flux measurement on high-temperature metallic surfaces.