Yuqing Qu

Dr. Yuqing Qu

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2024 in Processes
Verified
Journal Article
Open access
PDF file
NLNing Li
Ning Li
SSSipei Sun
Sipei Sun
LZLiang Zhang
Liang Zhang
JWJianjun Wang
Jianjun Wang
YQYuqing Qu
Yuqing Qu
The accurate quantification of power supply capability (PSC) is crucial for the planning and operation of active distribution networks. To address the issue of PSC quantification, this paper presents a PSC evaluation method of active distribution networks while considering demand response (DR). Firstly, an incentive-based DR model is introduced, followed by the development of a PSC evaluation model that incorporates DR. This model completely describes the PSC of active distribution networks while considering N-1 security constraints. Secondly, a PSC evaluation algorithm based on uniform state-space sampling is presented, enabling the quantification of the complete PSC of active distribution networks with DR. Then, the influence of the load reduction coefficient in DR on the PSC is studied. It is found that the maximum PSC increases with the load reduction coefficient initially and then stabilizes. Furthermore, measures such as appropriately increasing the load reduction coefficient and expanding the bottleneck component capacity are proposed to enhance the PSC. Finally, the effectiveness of the proposed PSC evaluation method is verified by two active distribution networks, CASE1 and CASE2. The proposed method visualizes the complete PSC of active distribution networks considering DR as a curve and quantifies it as an interval value. For CASE1, the complete PSC is quantified within the range of [4.0, 8.4] MVA, and for CASE2, it is quantified within the range of [17.0, 33.0] MVA. The proposed measures effectively enhance the PSC, facilitating the efficient, safe, and low-carbon operation of smart distribution networks.

3 April 2026 in Fractal and Fractional
Verified
Journal Article
Open access
PDF file
QYQun Yu
Qun Yu
Zhiyi ZhouZhiyi Zhou
Zhiyi Zhou
YJYan Jiongcheng
Yan Jiongcheng
WSWeimin Sun
Weimin Sun
YQYuqing Qu
Yuqing Qu
Power system blackouts represent typical manifestations of instability in complex systems, whose evolution often exhibits non-stationarity, long-range correlations, and nonlinear scaling behavior. Most reliability assessment methods widely used in engineering practice are built on the core assumptions of event independence and light-tailed distribution, which will inevitably lead to systematic underestimation of extreme tail risks when blackouts actually present long-range memory and power-law heavy-tailed characteristics. Based on long-cycle historical blackout records of China’s power grid spanning 1981–2025, this paper develops an integrated framework combining Self-Organized Criticality (SOC) theory, Hurst exponent analysis, symbolic time-series methods, and Multifractal Detrended Fluctuation Analysis (MFDFA). This study systematically characterizes the evolution law and inherent dependence structure of blackout events from four dimensions: statistical scaling, temporal correlation, nonlinear structure, and multi-scale fractal spectrum. The results show that both the load-loss magnitudes and inter-event intervals of blackouts follow strict power-law distributions, with the system exhibiting scaling behavior consistent with SOC theory. The blackout event sequence presents significant long-range positive correlation and self-similarity, confirming a persistent long-term memory effect in the system evolution. Symbolic analysis further reveals the nonlinear fluctuation patterns and burst clustering behavior of the blackout process, reflecting the intermittency and complexity of blackout risks. MFDFA results verify that the blackout sequence has a broad-spectrum multifractal structure across different temporal scales, and Monte Carlo shuffle tests demonstrate that this multifractality mainly arises from intrinsic long-range temporal correlations, rather than being driven solely by heavy-tailed distribution. This study confirms that blackouts in China’s power grid are not random independent events, but present fractal statistical characteristics consistent with the self-organized critical mechanism. The findings provide a novel fractal perspective and quantitative framework for the statistical characterization, operational security assessment, and multi-scale early-warning modeling of blackout risks in China’s large-scale power systems.

30 June 2026 in Energies
Verified
Journal Article
Open access
PDF file
JLJiangdong Liu
Jiangdong Liu
JHJun Han
Jun Han
JLJiajing Liu
Jiajing Liu
WDWenshu Ding
Wenshu Ding
LFLiang Feng
Liang Feng
YQYuqing Qu
Yuqing Qu
Rural distribution networks increasingly face voltage quality challenges due to high penetration of distributed renewable energy, heterogeneous rural load behavior, and long radial feeder structures with limited voltage regulation capability. Photovoltaic generation variability and agricultural load fluctuations can lead to voltage rise, reverse power flow, and branch congestion, particularly in weak rural grids. Conventional deterministic voltage control approaches relying on tap changers and capacitor banks often struggle to maintain stable voltage profiles under stochastic operating conditions. This paper proposes a risk-aware coordinated operation framework for rural multi-energy microgrids that integrates stochastic scenario modeling, voltage state perception, and adaptive optimization-based control. Renewable generation uncertainty and rural load variability are represented through correlated scenario generation and Wasserstein-distance-based scenario reduction, where 100 raw joint photovoltaic-load trajectories are reduced to 20 representative scenarios after convergence and distributional-fidelity tests. A stochastic optimization model is developed to coordinate photovoltaic inverters, battery energy storage systems, demand-side flexibility, and reactive compensation devices while satisfying network power-flow, voltage-security, storage, and communication-delay-aware implementation constraints. To mitigate extreme voltage deviation events, the framework incorporates a Conditional Value-at-Risk formulation that penalizes tail-risk voltage violations and maintains voltages within a preferred operating band of 0.97–1.03 p.u. Case studies on a modified IEEE 33-bus rural distribution system with 2.00 MW of photovoltaic capacity and 2.50 MWh of battery storage demonstrate consistent performance improvements across deterministic, risk-neutral stochastic, chance-constrained, and robust baselines. The proposed strategy reduces peak branch loading from 0.95 in the deterministic benchmark to 0.72, while the 95th percentile voltage deviation risk decreases from 0.0071 p.u.2 to 0.0020 p.u.2. Sensitivity, scenario-convergence, scalability, and seasonal representative-day analyses further confirm that the CVaR layer suppresses rare but severe voltage excursions without imposing excessive curtailment or computational burden.

12 June 2026 in Processes
Verified
Journal Article
Open access
PDF file
SSShumin Sun
Shumin Sun
SSshumin Sun
shumin Sun
SWShibo Wang
Shibo Wang
PYPeng Yu
Peng Yu
JXJiawei Xing
Jiawei Xing
YQYuqing Qu
Yuqing Qu
The mismatch between the DC voltage control bandwidth and the low-pass filter control bandwidth results in a non-virtual inertia phenomenon in the DC voltage of the DC microgrid. For this purpose, a transfer function model of the DC microgrid is established in this paper, and the causes of the non-virtual inertia phenomenon are explained from the perspective of control bandwidth. Secondly, a virtual inertia response criterion based on control bandwidth matching is presented in this paper. Then, the concept and solution method of the control bandwidth matching domain are also provided in this paper. This control bandwidth matching domain can not only effectively ensure the virtual inertia characteristics of the DC microgrid but also be used to evaluate the system’s virtual inertia strength under different low-pass filter control bandwidths. Experimental results show that when the ratio of the voltage control bandwidth to the low-pass filter control bandwidth is greater than 10, the DC microgrid presents virtual inertia characteristics; otherwise, it exhibits non-virtual inertia (damped oscillation) characteristics.