This paper presents a model predictive control (MPC)-based coordinated voltage control scheme for distribution networks with high penetration of distributed generation (DG) and energy storage. In this scheme, the DG units, energy storage devices, and on-load tap changer are optimally coordinated to maintain all bus voltages in the network within a permissible range. To better coordinate the economical operation and voltage regulation, two control modes are designed according to the operating conditions. In the preventive mode, the DG units operate in the maximum power point tracking mode. State-of-charge of energy storage system (ESS) units and power outputs of DG and ESS units are optimized while maintaining the voltages within the feasible range. In the corrective mode, active power curtailment of DG units is also used as a necessary method to correct the severe voltage deviations. The voltage sensitivity coefficients with respect to the power injections and tap changes are updated in real time using an analytical sensitivity calculation method to improve the computation efficiency. A test system consisting of two 20-kV feeders fed from the same substation based on a real distribution network was used to validate the proposed coordinated voltage control scheme under both normal and large-disturbance conditions.
16 November 2016 in IEEE Transactions on Power Delivery
With the high penetration of distributed generations (DGs), the conventional radial distribution network is becoming an active distribution network (ADN). It has the characteristics of multisource, multibranch, bidirectional power and fault current flow, as well as weak infeed. To provide effective protection for such a network, a novel current differential protection scheme, together with new implementation technology, is proposed in this paper. In this scheme, instead of using phase currents, a positive-sequence fault component (PSFC) is introduced into the differential protection. By building the PSFC equivalent circuit of the ADN, the distribution characteristic of PSFC within the ADN is theoretically analyzed in detail, especially for the case when the ADN contains inverter interfaced DGs. The PSFC-based differential protection criteria for different types of feeder are then established and simulated. To put the scheme into practice, data self-synchronization and peer-to-peer communication techniques are established. Based on this principle and using an advanced hardware platform, a protection prototype is successfully developed and tested. The test results verify the feasibility of the proposed protection scheme.
22 August 2017 in IEEE Transactions on Sustainable Energy
This paper proposes an enhanced voltage control strategy (EVCS) based on model predictive control (MPC) for voltage-source-converter-based high-voltage direct-current (VSC-HVDC)-connected offshore wind farms (OWFs). In the proposed MPC-based EVCS, all wind turbine generators (WTGs) and the wind-farm-side VSCs are optimally coordinated to keep voltages within the feasible range and reduce system power losses. Considering the high R/X ratio of the OWF collector system, the effects of active power outputs of WTGs on voltage control are also taken into consideration. The predictive model of the VSC with a typical cascaded control structure is derived in detail. The sensitivity coefficients are calculated by an analytical method to improve the computational efficiency. A VSC-HVDC-connected OWF with 64 WTGs was used to validate the proposed voltage control strategy.
1 January 2019 in IEEE Transactions on Sustainable Energy
This paper proposes a double-time-scale coordinated voltage control scheme for distribution networks with distributed generators (DGs) based on the Model Predictive Control (MPC) to regulate the voltage across the network in different time scales by optimally coordinating multiple voltage regulation devices. In the upper-level control (ULC), a slow-time-scale control scheme is designed to correct the long-term voltage deviations while minimizing the number of actions of the on-load tap changer (OLTC), step voltage regulators (SVRs) and capacitor banks (CBs). The MPC problem is formulated as a mixed-integer quadratic programming (MIQP). A tailored exaction solution method based on the Branch-and-Bound (B&B) algorithm embedded with an Alternating Direction Method of Multipliers (ADMM)-based QP solver is proposed to efficiently solve the MIQP without loss of optimality. In the lower-level control (LLC), the active and reactive powers of DGs are optimally coordinated to handle the fast-time-scale voltage fluctuations as well as capture more renewable energy. An efficient analytical sensitivity calculation method is used to online update the voltage sensitivity coefficients. The effectiveness of the proposed control scheme along with the exact solution method is verified on a modified real 20kV distribution system.
18 June 2018 in IEEE Transactions on Sustainable Energy
This paper proposes a decentralized coordinated voltage control scheme (DCVCS) for voltage-source-converter high voltage direct current (VSC-HVDC) connected wind farms based on the Model Predictive Control (MPC) which regulates the voltage profile across the wind farm network within the feasible range by optimally coordinating the VSC and wind turbines (WTs). Firstly, the centralized voltage control problem based on the MPC is formulated to minimize voltage deviations and reactive power output fluctuations of WTs. Secondly, the decentralized solution methodology based on Alternating Direction Method of Multipliers (ADMM) with fast convergency is used to solve the MPC problem in a decentralized manner without losing the optimality of the primal problem. A wind farm with 64 WTs was used to validate the effectiveness and optimality of the proposed DCVCS.
25 January 2024 in IEEE Transactions on Sustainable Energy
Existing low-voltage ride-through (LVRT) methods of virtual synchronous generators (VSGs) are facing the problem of inverter damage due to prolonged overcurrent caused by the delay in fault detection. Additionally, the newly updated grid codes (GCs) mandate that inverter-based resources (IBRs) should inject negative-sequence current during asymmetrical faults. To address this issue while complying with the new GCs, this article proposes an adaptive LVRT method. At the onset of the fault, the proposed method compensates for the voltage difference between the reference and feedback values of voltage control loop, while simultaneously adjusting the angle output of the active power loop based on the phase change of the point of connection (POC) voltage and the active power output of the VSG. Thus, it enables a seamless transition between normal and LVRT conditions. Furthermore, it complies with the new GCs and guarantees the maximum utilization of the phase current. The method offers two notable advantages. First, it can achieve fast fault current limitation without the need for fault detection. Second, it eliminates the necessity for parameter design, making it straightforward to implement. The simulation results in PSCAD confirm the effectiveness of the proposed method under different asymmetrical fault conditions.