Each historic building or cultural heritage site requires proper care at every stage of its life cycle. Appropriate interventions aim to prevent building disasters and preserve invaluable cultural objects from ageing or deterioration processes. This article is a case study of mistakes made in various phases of a building’s life—in the design, execution, and use. The work aims to point out various aspects of the errors made during the building’s restoration. The conducted material research, computational analyses, laboratory tests, and documentation studies comprehensively consider the presented examples. The structural analysis of the buildings consists of its load-bearing capacity and its stability.
Non-destructive testing (NDT) methods are a diagnostic tool for evaluating the risk of failure or the need for repair and renovation. In analyzing constructions of high historical value, destructive diagnostic methods should be avoided. This study is a comprehensive NDT investigation of the masonry tower topped with a steel dome, a remnant of the overhead telecommunications network from the end of the 19th century. Visual inspection and research made it possible to assess the degree of damage to the structure. Stress–strain state analysis showed the sufficient load-bearing capacity of the steel dome. In addition, calculations have shown that the masonry tower is subjected to significant horizontal forces causing structure cracks.
In this study, qualitative tests were carried out to compare the behaviour of selected slabs exposed to short- and long-term loading. Full-scale models of the half-slab and hollow-core slab with dimensions of 6.30 m × 6.30 m, built of four different precast panels, were tested. The first two were semi-precast lattice girder slabs, the third semi-precast prestressed ribbed panels, and the last was composed of hollow-core panels. A common feature was the lack of joint reinforcement and the same modular width of 600 mm. The short-term load was applied sequentially in the first stage, and displacement was measured using an electronic method. In the second stage of long-term testing, the load was mainly applied to one part of the slab. Testing under short-term and long-term load allows determining the change in the performance of panel slabs over time. The panels maintained the ability of load redistribution based on their interaction despite the work of the longitudinal joints being only through the concrete cross-section. The behaviour of slabs with concrete topping shows more significant lateral interactions than elements connected only by shear key. Comparative calculations were made based on four computational models. Comparative analysis showed that the current design procedures lead to a safe but conservative estimation of the slab behaviour.
Experimental identification of stiffening walls is often limited to studying single-wall models. However, these samples do not reflect many additional effects—torsion of the building and redistribution of internal forces. This paper presents the results of two full-scale buildings made of autoclaved aerated concrete (AAC) masonry elements. The primary purpose of the work was to determine the changes in the stiffness of the shear walls and to attempt the empirical distribution of loads on the stiffening walls. The intermediate goals were: a description of the crack morphology and the mechanism of failure, the designation of the stiffening walls’ behavior. It was shown that the first crack formed in the tensile corner of the door opening, and the subsequent cracks formed in the wall without a hole. Based on the changes in the value of the shear deformation angles, the phases of work of the stiffening walls were determined. The presented research results are only a part of an extensive study of stiffening walls in masonry buildings conducted at the Silesian University of Technology.