Cristina Rodriguez

Prof. Dr. Cristina Rodriguez

Department of Electronics, Universidad Rey Juan Carlos, Spain
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2014 in Expert Systems with Applications
Verified
Journal Article
Closed access
Cristina RodriguezCristina Rodriguez
Cristina Rodriguez
MMM.A. Moreno-Alvarez
M.A. Moreno-Alvarez
Estefanía Martín-BarrosoEstefanía Martín-Barroso
Estefanía Martín-Barroso
Susana BorromeoSusana Borromeo
Susana Borromeo
JHJ.A. Hernandez-Tamames
J.A. Hernandez-Tamames

15 December 2021 in Electronics
Verified
Journal Article
Open access
PDF file
EAEduardo Alcaín
Eduardo Alcaín
PFPedro Fernández
Pedro Fernández
RNRubén Nieto
Rubén Nieto
AMAntonio S. Montemayor
Antonio S. Montemayor
JVJaime Vilas
Jaime Vilas
ATAngel Torrado-Carvajal
Angel Torrado-Carvajal
Medical imaging is considered one of the most important advances in the history of medicine and has become an essential part of the diagnosis and treatment of patients. Earlier prediction and treatment have been driving the acquisition of higher image resolutions as well as the fusion of different modalities, raising the need for sophisticated hardware and software systems for medical image registration, storage, analysis, and processing. In this scenario and given the new clinical pipelines and the huge clinical burden of hospitals, these systems are often required to provide both highly accurate and real-time processing of large amounts of imaging data. Additionally, lowering the prices of each part of imaging equipment, as well as its development and implementation, and increasing their lifespan is crucial to minimize the cost and lead to more accessible healthcare. This paper focuses on the evolution and the application of different hardware architectures (namely, CPU, GPU, DSP, FPGA, and ASIC) in medical imaging through various specific examples and discussing different options depending on the specific application. The main purpose is to provide a general introduction to hardware acceleration techniques for medical imaging researchers and developers who need to accelerate their implementations.

18 November 2010 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Cristina RodriguezCristina Rodriguez
Cristina Rodriguez
Susana BorromeoSusana Borromeo
Susana Borromeo
JHJ. A. Hernández-Tamames
J. A. Hernández-Tamames
Recently, technology has become more attractive for industry by paving the way to new applications, which go well beyond traditional sensor applications. These applications can be classified in different categories: monitoring, alerting, healthcare assistance, and actuating, among others. A Wireless Sensor Network (WSN) is feasible for the heritage scenarios protection and for monitoring because its specificity, autonomy, self-configurability, lasting lifetime, and mobility. However, their services, protocols, and architectures have constraints to support new issues for monitoring cultural assets: geographical dispersion, insufficient resources, and not enough staff to protect all the monuments and to provide tourist information broadcasting. We propose a modular system. It consists of three elements: a WSN, a “Central System,” and a novel platform named “Local Node Gateway.” It allows the coexistence of different wireless technologies in order to provide actuation, processing and communication functionalities. This proposal takes a new approach to solve these heritage-monitoring problems.

29 February 2016 in IEEE Transactions on Education
Verified
Journal Article
Closed access
Cristina RodriguezCristina Rodriguez
Cristina Rodriguez
ATAngel Torrado-Carvajal
Angel Torrado-Carvajal
Joaquin VaqueroJoaquin Vaquero
Joaquin Vaquero
Susana BorromeoSusana Borromeo
Susana Borromeo
JHJuan A. Hernandez-Tamames
Juan A. Hernandez-Tamames
This paper presents a case study analyzing the advantages and disadvantages of using project-based learning (PBL) combined with collaborative learning (CL) and industry best practices, integrated with information communication technologies, open-source software, and open-source hardware tools, in a specialized microcontroller and embedded systems engineering Master's course. In addition to addressing industry requirements in both contents and methodology, the course develops capabilities and competencies in problem solving, independent learning, teamwork, and technical knowledge. Since PBL methodology alone does not ensure teamwork, it was complemented with CL. Design review meetings (as described in IEC 61160), deliverables, and organizational resources were also introduced to mirror industry demands. This structure integrated course content and student academic achievement in a simulated industrial environment. The course had students build a modular management system for home appliances, implementing control software on the “Arduino” open-source platform, as well as using wireless communications. The results show that teaching, learning, and student assessment processes can be improved by using PBL with CL. In addition, the introduction of industry practices, such us peer review meetings, brings academia closer to a real-world context.

24 November 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JMJesus Morón-López
Jesus Morón-López
Cristina RodriguezCristina Rodriguez
Cristina Rodriguez
FCFrancisco Carreno
Francisco Carreno
Joaquin VaqueroJoaquin Vaquero
Joaquin Vaquero
APAngel G. Pompa-Pernia
Angel G. Pompa-Pernia
JAJuan Antonio Pascual Aguilar
Juan Antonio Pascual Aguilar
The deployment of Remote Monitoring System (RMS) based on Internet of Things (IoT) technologies and data management in the cloud is a cutting-edge solution for water management agencies to track harmful algae blooms (HABs). However, each environment presents different intrinsic characteristics, hence the reliability and representativeness of collected data may vary according to the selected RMS architecture. This study aims to implement the same RMS in two different water bodies in Spain: the freshwater As Conchas reservoir and the shallow L’Albufera brackish water lagoon. We firstly evaluate the pros and cons of current technologies available on the market and then we select an RMS based on a combination of plug-and-play (YSI-based) and customisable solutions (Libelium-based). The deployment of nodes on buoys allows big data collection from different areas of water bodies, their continuous transfer and storage on a web server, and their subsequent visualisation on the web interface in real time. Secondly, in order to know whether the selected RMS architecture and monitored environment influence the representativeness of the collected data, we perform a Pearson correlation test between the deployed nodes and satellite images. The results point out that the more heterogeneous the environment is, the more nodes must be deployed in different areas for a longer time to obtain a realistic view of the water body status. Therefore, this study provides critical and empirical data to implement a profitable and effective real-time monitoring system in other HAB-affected areas.

1 September 2017 in Annals of Medicine & Surgery
Verified
Journal Article
Open access
Juan José Segura-SampedroJuan José Segura-Sampedro
Juan José Segura-Sampedro
IBInes Rivero Belenchon
Ines Rivero Belenchon
VPVerónica Pino-Díaz
Verónica Pino-Díaz
Cristina RodriguezCristina Rodriguez
Cristina Rodriguez
FPFelipe Pareja-Ciuró
Felipe Pareja-Ciuró
RJRosa María Jimenez-Rodriguez
Rosa María Jimenez-Rodriguez
The objective of the present study is to assess the safety and feasibility of the use of telemedicine-based services for surgical wound care and to measure patient satisfaction with telemedicine-based follow-up. 24 patients were included, they were provided with a corporate mail address. On day 7 after surgery patients sent, via email, an image of their surgical wound together with a completed questionnaire in order to obtain an early diagnosis. Two independent physicians studied this information and the histologic analysis of the specimen. On day 8, all patients underwent face-to-face office examination by a third physician and all of them completed a satisfaction questionnaire at the end of the study. The use of telemedicine-based services showed a sensitivity of 100%, a specificity of 91.6%, a positive predictive value of 75% and a negative predictive value of 100%. Degree of concordance between the two physicians, as regards the necessity of face-to-face follow-up yielded a kappa coefficient of 0.42 (standard error 0.25 and confidence interval 95% (0.92-0.08), which means a moderate agreement between the two evaluations. 94% of patients were satisfied with telemedicine-based follow-up and 93% showed their preference for this procedure over conventional methods. The telemedicine-based follow-up, has proven to be feasible and safe for the evaluation of early postoperative complications. Patients reported high levels of satisfaction with the procedure. Telemedicine-based follow-up could become standard practice with the development of a specific mobile application.