Large-diameter buried steel pipes (BSPs) have been widely utilized in water diversion and hydropower fields. This paper presents a comprehensive numerical investigation on the interaction between the large-diameter pipe and soil under three typical working conditions, to capture the structural mechanical behaviors of pipe deformation, soil displacement, and soil pressure. Furthermore, a parametric analysis of pipe diameter is conducted, along with the sensitivity study of soil parameters based on the orthogonal test method. The results show that the water weight increases the pipe deformation significantly by 14%, while the high internal water pressure decreases the deformation greatly with the maximum effect of 39%. The pattern of soil pressure at the top of the pipe changes from parabola to double-hump as the pipe diameter varies from 0.5 m to 5.0 m. The pipe deformation and soil pressure keep increasing with the pipe diameter, but the safety margin for prism load decreases gradually. Pipe deformation and soil pressure are very sensitive to the elastic modulus and Poisson’s ratio of backfill. Friction coefficients of soil-soil (trench sidewall) and pipe-soil have great influences on the soil pressure, while the bedding material and backfill cohesion have small effects on it.
Under the circumstances of rapid expansion of diverse forms of volatile and intermittent renewable energy sources, hydropower stations have become increasingly indispensable for improving the quality of energy conversion processes. As a consequence, Francis turbines, one of the most popular options, need to operate under off-design conditions, particularly for partial load operation. In this paper, a prototype Francis turbine was used to investigate the pressure fluctuations and hydraulic axial thrust pulsation under four partial load conditions. The analyses of pressure fluctuations in the vaneless space, runner, and draft tube are discussed in detail. The observed precession frequency of the vortex rope is 0.24 times that of the runner rotational frequency, which is able to travel upstream (from the draft tube to the vaneless space). Frequencies of both 24.0 and 15.0 times that of the runner rotational frequency are detected in the recording points of the runner surface, while the main dominant frequency recorded in the vaneless zone is 15.0 times that of the runner rotational frequency. Apart from unsteady pressure fluctuations, the pulsating property of hydraulic axial thrust is discussed in depth. In conclusion, the pulsation of hydraulic axial thrust is derived from the pressure fluctuations of the runner surface and is more complicated than the pressure fluctuations.
13 August 2018 in Latin American Journal of Solids and Structures
A spiral case with its steel spiral case (SSC) being embedded in reinforced concrete under a pressurized condition is called a preloaded filling spiral case structure (PFSCS) in a hydropower plant. As a steel-concrete composite structure, a PFSCS is designed to work reliably. The non-uniform gap and contact nonlinearity between the SSC and the surrounding mass concrete have a great effect on the bearing mechanism of the composite structure. However, the description of the gap and contact nonlinearity in a PFSCS is a tough work. With the aim of efficiently describing the evolution process of the non-uniform gap and contact nonlinearity, we performed an experimental investigation and proposed a novel numerical simulation technique for structural finite element analyses (FEA) of PFSCSs. In the technique, the gap and contact nonlinearity as well as the construction process and operation process of a PFSCS are taken into account. A friction-contact model is used to simulate the sliding of the SSC against the concrete. A plasticity damage model is employed to describe the concrete. The development of the gap, contact status between the steel liner and the surrounding concrete, stresses of the steel liner and the steel bars, as well as the concrete cracking time and crack pattern, are presented in this work. The FEA results agree well with the experimental results. The agreement provides evidence that the applicability and competence of the proposed technique are valid and satisfactory.
25 March 2016 in STRUCTURAL ENGINEERING AND MECHANICS
Flat-bottomed design philosophy of Y-typed bifurcations in hydropower stations hydropower;bifurcation;flat-bottomed;design philosophy;finite element modeling;computational fluid dynamics; The drainage problem in bifurcations causes pecuniary losses when hydropower stations are undergoing periodic overhaul. A new design philosophy for Y-typed bifurcations that are flat-bottomed is proposed. The bottoms of all pipe sections are located at the same level, making drainage due to gravity possible and shortening the draining time. All fundamental curves were determined, and contrastive analysis with a crescent-rib reinforced bifurcation in an actual project was conducted. Feasibility demonstrations were researched including structural characteristics based on finite element modeling and hydraulic characteristics based on computational fluid dynamics. The new bifurcation provided a well-balanced shape and reasonable stress state. It did not worsen the flow characteristics, and the head loss was considered acceptable. The proposed Y-typed bifurcation was shown to be suitable for pumped storage power stations.
High-performance fiber-reinforced concrete (HPFRC) offers exceptional strength, ductility, and durability, making it highly promising for electric power pipe jacking applications. However, limited research exists on the mechanical properties of HPFRC pipes, especially regarding reinforcement schemes. This study bridges this gap by using a combination of three-point testing, analytical calculations, and numerical simulations to investigate the mechanical behavior and performance of HPFRC pipes under various reinforcement configurations. The results show that the load–displacement curve of HPFRC pipes initially follows a linear elastic relationship, but as the load exceeds 200 kN/m, displacement increases and cracks form, with failure occurring at 410 kN/m. HPFRC pipes demonstrate significantly enhanced load-bearing and crack resistance capabilities, with reduced reinforcement and wall thickness compared to traditional materials, maintaining high load-bearing capacity even after damage. The three analysis methods generally align in terms of load-bearing and failure processes, though the analytical method reveals limitations in accurately predicting crack widths. The study also reveals that reinforcement schemes significantly affect the pipes’ structural performance, with double layer and inner layer reinforcement providing superior damage resistance. This study contributes new insights into HPFRC pipe performance and provides a basis for optimizing reinforcement designs in pipe jacking projects.
1 December 2021 in KSCE Journal of Civil Engineering
Large-diameter buried steel pipes (BSPs) play critical roles in water transport for major water diversion and hydropower projects. Due to poor pipe-soil composite system properties and installation conditions, they are prone to excessive deformation, resulting in safety hazards. This paper takes a BSP project subjected to excessive deformation as an example. A simplified numerical model is first established to analyze the structural performance, including the stress and plasticity, and the relationship between the stress and deformation of the pipe. Furthermore, a jacking method to rehabilitate the pipe-soil composite system is conducted to explore its influences on pipe deformation, stress, and plasticity. The results show that considerable bending stresses occur in the pipe and that sections of the midspan and stiffening ring are in the pure bending state and eccentric bending state, respectively. Areas of high stress and plasticity center at the crown, springline, and invert of the pipe, and steel pipes with ring deformation of 8.9% can be continued to be used, as the full yielding of the pipe walls occurs at the ring deformation of 15.8%. The jacking method is an effective solution for the rehabilitation of BSPs subjected to large deformation and can reduce pipe deformation significantly while increasing the stress at the pipe crown and the pipe plasticity only slightly.