Nikolaos Gatsis

Dr. Nikolaos Gatsis

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2017 in IEEE Communications Surveys & Tutorials
Verified
Journal Article
Closed access
AKAli Khalajmehrabadi
Ali Khalajmehrabadi
NGNikolaos Gatsis
Nikolaos Gatsis
DADavid Akopian
David Akopian
Wireless local area networks (WLANs) have become a promising choice for indoor positioning as the only existing and established infrastructure, to localize the mobile and stationary users indoors. However, since WLANs have been initially designed for wireless networking and not positioning, the localization task based on WLAN signals has several challenges. Amongst the WLAN positioning methods, WLAN fingerprinting localization has recently garnered great attention due to its promising performance. Notwithstanding, WLAN fingerprinting faces several challenges and hence, in this paper, our goal is to overview these challenges and corresponding state-of-the-art solutions. This paper consists of three main parts: 1) conventional localization schemes; 2) state-of-the-art approaches; and 3) practical deployment challenges. Since all proposed methods in the WLAN literature have been conducted and tested in different settings, the reported results are not readily comparable. So, we compare some of the representative localization schemes in a single real environment and assess their localization accuracy, positioning error statistics, and complexity. Our results depict illustrative evaluation of the approaches in the literature and guide to future improvement opportunities.

28 July 2017 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
MBMohammadhafez Bazrafshan
Mohammadhafez Bazrafshan
NGNikolaos Gatsis
Nikolaos Gatsis
The theme of this paper is three-phase distribution system modeling suitable for the Z-Bus load-flow. Detailed models of wye and delta constant-power, constant-current, and constant-impedance loads are presented. Models of transmission lines, step-voltage regulators, and transformers that build the bus admittance matrix (Y-Bus) are laid out. The Z-Bus load-flow is then reviewed and the singularity of the Y-Bus in case of certain transformer connections is rigorously discussed. Based on realistic assumptions and conventional modifications, the invertibility of the Y-Bus is proved. Last but not least, MATLAB scripts that model the components of the IEEE 37-bus, the IEEE 123-bus, the 8500-node feeders, and the European 906-bus low-voltage feeder are provided.

27 April 2020 in IEEE Transactions on Aerospace and Electronic Systems
Verified
Journal Article
Closed access
ESErick Schmidt
Erick Schmidt
NGNikolaos Gatsis
Nikolaos Gatsis
DADavid Akopian
David Akopian
This work proposes a global navigation satellite system (GNSS) spoofing detection and classification technique for single antenna receivers. We formulate an optimization problem at the baseband correlator domain by using the Least Absolute Shrinkage and Selection Operator (LASSO). We model correlator tap outputs of the received signal to form a dictionary of triangle-shaped functions and leverage sparse signal processing to choose a decomposition of shifted matching triangles from said dictionary. The optimal solution of this minimization problem discriminates the presence of a potential spoofing attack peak by observing a decomposition of two different code-phase values (authentic and spoofed) in a sparse vector output. We use a threshold to mitigate false alarms. Furthermore, we present a variation of the minimization problem by enhancing the dictionary to a higher-resolution of shifted triangles. The proposed technique can be implemented as an advanced fine-acquisition monitoring tool to aid in the tracking loops for spoofing mitigation. In our experiments, we are able to distinguish authentic and spoofer peaks from synthetic data simulations and from a real dataset, namely, the Texas Spoofing Test Battery (TEXBAT). The proposed method achieves 0.3% detection error rate (DER) for a spoofer attack in nominal signal-to-noise ratio (SNR) conditions and an authentic-over-spoofer power of 3 dB.

25 April 2018 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
PRParesh Risbud
Paresh Risbud
NGNikolaos Gatsis
Nikolaos Gatsis
ATAhmad Taha
Ahmad Taha
Sensors such as phasor measurement units (PMUs) endowed with GPS receivers are ubiquitously installed providing real-time grid visibility. A number of PMUs can cooperatively enable state estimation routines. However, GPS spoofing attacks can notably alter the PMU measurements, mislead the network operator, and drastically impact subsequent corrective control actions. Leveraging a novel measurement model that explicitly accounts for the GPS spoofing attacks, this paper formulates an optimization problem to identify the most vulnerable PMUs in the network. A greedy algorithm is developed to solve the aforementioned problem. Furthermore, the paper develops a computationally efficient alternating minimization algorithm for joint state estimation and attack reconstruction. Numerical tests on IEEE benchmark networks validate the developed methods.

3 February 2016 in IEEE Transactions on Smart Grid
Verified
Journal Article
Open access
MBMohammadhafez Bazrafshan
Mohammadhafez Bazrafshan
NGNikolaos Gatsis
Nikolaos Gatsis
This paper develops a power management scheme that jointly optimizes the real power consumption of programmable loads and reactive power outputs of photovoltaic (PV) inverters in distribution networks. The premise is to determine the optimal demand response schedule that accounts for the stochastic availability of solar power, as well as to control the reactive power generation or consumption of PV inverters adaptively to the real power injections of all PV units. These uncertain real power injections by PV units are modeled as random variables taking values from a finite number of possible scenarios. Through the use of second order cone relaxation of the power flow equations, a convex stochastic program is formulated. The objectives are to minimize the negative user utility, cost of power provision, and thermal losses, while constraining voltages to remain within specified levels. To find the global optimum point, a decentralized algorithm is developed via the alternating direction method of multipliers that results in closed-form updates per node and per scenario, rendering it suitable to implement in distribution networks with a large number of scenarios. Numerical tests and comparisons with an alternative deterministic approach are provided for typical residential distribution networks that confirm the efficiency of the algorithm.

23 September 2019 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
MJMana Jalali
Mana Jalali
VKVassilis Kekatos
Vassilis Kekatos
NGNikolaos Gatsis
Nikolaos Gatsis
DDDeepjyoti Deka
Deepjyoti Deka
Smart inverters have been advocated as a fast-responding mechanism for voltage regulation in distribution grids. Nevertheless, optimal inverter coordination can be computationally demanding, and preset local control rules are known to be subpar. Leveraging tools from machine learning, the design of customized inverter control rules is posed here as a multitask learning problem. Each inverter control rule is modeled as a possibly nonlinear function of local and/or remote control inputs. Given the electric coupling, the function outputs interact to yield the feeder voltage profile. Using an approximate grid model, inverter rules are designed jointly to minimize a voltage deviation objective based on anticipated load and solar generation scenarios. Each control rule is described by a set of coefficients, one for each training scenario. To reduce the communication overhead between the grid operator and the inverters, we devise a voltage regulation objective that is shown to promote parsimonious descriptions for inverter control rules. Numerical tests using real-world data on a benchmark feeder demonstrate the advantages of the novel nonlinear rules and explore the trade-off between voltage regulation and sparsity in rule descriptions.