Anis Davoudi

Ms. Anis Davoudi


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2019 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
TMTodd Matthew Manini
Todd Matthew Manini
TMTonatiuh Mendoza
Tonatiuh Mendoza
MBManoj Battula
Manoj Battula
ADAnis Davoudi
Anis Davoudi
MKMatin Kheirkhahan
Matin Kheirkhahan
PRParisa Rashidi
Parisa Rashidi
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Chronic pain, including arthritis, affects about 100 million adults in the United States. Complexity and diversity of pain experience across time and people and its fluctuations across and within days show the need for valid pain reports that do not rely on patient’s long-term recall capability. Smartwatches can be used as digital ecological momentary assessment (EMA) tools for real-time collection of pain scores. Smartwatches are generally less expensive than a smartphone, are highly portable, and have a simpler user interface, providing an excellent medium for continuous data collection and enabling a higher compliance rate. Objective: The aim of this study was to explore the attitudes and perceptions of older adults towards smartwatch technology for measuring patient report outcomes (PRO) as an EMA tool. Methods: A focus group session was conducted to explore the perception of participants towards smartwatch technology and its utility for PRO assessment. Participants included older adults (age > 65), with uniliateral or bilateral symptomatic knee Osteoaethritis (OA). A preliminary user interface with server communication capability was developed and deployed on 10 Samsung Gear S3 smartwatches and provided to the users during the focus group. Pain was designated as the main PRO, while fatigue, mood, and sleep quality were included as auxiliary PROs. Pre-planned topics included participants’ attitude towards the smartwatch technology, usability of the custom-designed app interface, and suitability of the smartwatch technology for PRO assessment. Discussions were transcribed and content analysis with theme characterization was performed to identify and code the major themes. Results: Twenty participants (age 65+) were recruited and consented to take part in the focus group study. The overall attitude of the participants towards the smartwatch technology was positive, and they showed interest in the direct phone call capability, availability of extra apps such as the weather apps, and sensors for tracking health and wellness such as accelerometer and heart rate sensor; with 74% of the participants showing willingness to participate in a 1-year study to wear the watch daily. Concerns were raised regarding usability, including accessibility (larger icons), notification customization, and intuitive interface design (unambiguous icons and assessment scales). Participants expresses interest in using smartwatch technology for PRO assessment and availability of methods for sharing data with healthcare providers. Conclusions: All participants had overall positive views of the smartwatch technology for measuring OPROs to facilitate patient-provider communications, and to provide more targeted treatments and interventions in the future. Usability concerns were the major issues that will require special considerations in future smartwatch PRO user interface design, especially accessibility issues, notification design, and use of intuitive assessment scales.

1 October 2017
Verified
Conference Paper
Closed access
ADAnis Davoudi
Anis Davoudi
TOTezcan Ozrazgat-Baslanti
Tezcan Ozrazgat-Baslanti
Ashkan EbadiAshkan Ebadi
Ashkan Ebadi
ABAlberto C. Bursian
Alberto C. Bursian
Azra BihoracAzra Bihorac
Azra Bihorac
PRParisa Rashidi
Parisa Rashidi
Electronic Health Records are mainly designed to record relevant patient information during their stay in the hospital for administrative purposes. They additionally provide an efficient and inexpensive source of data for medical research, such as patient outcome prediction. In this study, we used preoperative Electronic Health Records to predict postoperative delirium. We compared the performance of seven machine learning models on delirium prediction: linear models, generalized additive models, random forests, support vector machine, neural networks, and extreme gradient boosting. Among the models evaluated in this study, random forests and generalized additive model outperformed the other models in terms of the overall performance metrics for prediction of delirium, particularly with respect to sensitivity. We found that age, alcohol or drug abuse, socioeconomic status, underlying medical issue, severity of medical problem, and attending surgeon can affect the risk of delirium.

3 May 2021 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
ADAnis Davoudi
Anis Davoudi
MMMamoun T Mardini
Mamoun T Mardini
DNDavid Nelson
David Nelson
FAFahd Albinali
Fahd Albinali
SRSanjay ranka
Sanjay ranka
TMTodd M Manini
Todd M Manini
Background: Research has shown the feasibility of human activity recognition using wearable accelerometer devices. Different studies have used varying numbers and placements for data collection using sensors. Objective: This study aims to compare accuracy performance between multiple and variable placements of accelerometer devices in categorizing the type of physical activity and corresponding energy expenditure in older adults. Methods: In total, 93 participants (mean age 72.2 years, SD 7.1) completed a total of 32 activities of daily life in a laboratory setting. Activities were classified as sedentary versus nonsedentary, locomotion versus nonlocomotion, and lifestyle versus nonlifestyle activities (eg, leisure walk vs computer work). A portable metabolic unit was worn during each activity to measure metabolic equivalents (METs). Accelerometers were placed on 5 different body positions: wrist, hip, ankle, upper arm, and thigh. Accelerometer data from each body position and combinations of positions were used to develop random forest models to assess activity category recognition accuracy and MET estimation. Results: Model performance for both MET estimation and activity category recognition were strengthened with the use of additional accelerometer devices. However, a single accelerometer on the ankle, upper arm, hip, thigh, or wrist had only a 0.03-0.09 MET increase in prediction error compared with wearing all 5 devices. Balanced accuracy showed similar trends with slight decreases in balanced accuracy for the detection of locomotion (balanced accuracy decrease range 0-0.01), sedentary (balanced accuracy decrease range 0.05-0.13), and lifestyle activities (balanced accuracy decrease range 0.04-0.08) compared with all 5 placements. The accuracy of recognizing activity categories increased with additional placements (accuracy decrease range 0.15-0.29). Notably, the hip was the best single body position for MET estimation and activity category recognition. Conclusions: Additional accelerometer devices slightly enhance activity recognition accuracy and MET estimation in older adults. However, given the extra burden of wearing additional devices, single accelerometers with appropriate placement appear to be sufficient for estimating energy expenditure and activity category recognition in older adults.

6 February 2019 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
ADAnis Davoudi
Anis Davoudi
AWAmal A Wanigatunga
Amal A Wanigatunga
MKMatin Kheirkhahan
Matin Kheirkhahan
DCDuane Benjamin Corbett
Duane Benjamin Corbett
TMTonatiuh Mendoza
Tonatiuh Mendoza
PRParisa Rashidi
Parisa Rashidi
Background: Wearable accelerometers have greatly improved measurement of physical activity, and the increasing popularity of smartwatches with inherent acceleration data collection suggest their potential use in the physical activity research domain; however, their use needs to be validated. Objective: This study aimed to assess the validity of accelerometer data collected from a Samsung Gear S smartwatch (SGS) compared with an ActiGraph GT3X+ (GT3X+) activity monitor. The study aims were to (1) assess SGS validity using a mechanical shaker; (2) assess SGS validity using a treadmill running test; and (3) compare individual activity recognition, location of major body movement detection, activity intensity detection, locomotion recognition, and metabolic equivalent scores (METs) estimation between the SGS and GT3X+. Methods: To validate and compare the SGS accelerometer data with GT3X+ data, we collected data simultaneously from both devices during highly controlled, mechanically simulated, and less-controlled natural wear conditions. First, SGS and GT3X+ data were simultaneously collected from a mechanical shaker and an individual ambulating on a treadmill. Pearson correlation was calculated for mechanical shaker and treadmill experiments. Finally, SGS and GT3X+ data were simultaneously collected during 15 common daily activities performed by 40 participants (n=12 males, mean age 55.15 [SD 17.8] years). A total of 15 frequency- and time-domain features were extracted from SGS and GT3X+ data. We used these features for training machine learning models on 6 tasks: (1) individual activity recognition, (2) activity intensity detection, (3) locomotion recognition, (4) sedentary activity detection, (5) major body movement location detection, and (6) METs estimation. The classification models included random forest, support vector machines, neural networks, and decision trees. The results were compared between devices. We evaluated the effect of different feature extraction window lengths on model accuracy as defined by the percentage of correct classifications. In addition to these classification tasks, we also used the extracted features for METs estimation. Results: The results were compared between devices. Accelerometer data from SGS were highly correlated with the accelerometer data from GT3X+ for all 3 axes, with a correlation ≥.89 for both the shaker test and treadmill test and ≥.70 for all daily activities, except for computer work. Our results for the classification of activity intensity levels, locomotion, sedentary, major body movement location, and individual activity recognition showed overall accuracies of 0.87, 1.00, 0.98, 0.85, and 0.64, respectively. The results were not significantly different between the SGS and GT3X+. Random forest model was the best model for METs estimation (root mean squared error of .71 and r-squared value of .50). Conclusions: Our results suggest that a commercial brand smartwatch can be used in lieu of validated research grade activity monitors for individual activity recognition, major body movement location detection, activity intensity detection, and locomotion detection tasks.

3 August 2018 in Food & Function
Verified
Journal Article
Closed access
PDF file
SPShirin Pourafshar
Shirin Pourafshar
NANeda S. Akhavan
Neda S. Akhavan
KGKelli George
Kelli George
EFElizabeth Marie Foley
Elizabeth Marie Foley
Sarah JohnsonSarah Johnson
Sarah Johnson
Bahram ArjmandiBahram Arjmandi
Bahram Arjmandi
Without appropriate interventions, prediabetes is typically followed by type II diabetes. Eggs are a rich source of important nutrients including protein, vitamins, minerals, carotenoids and lecithin. In this 12-week, parallel, randomized controlled trial, 42 overweight or obese individuals between the ages of 40 and 75 years with pre- and type II-diabetes were included. Participants were randomly assigned to receive either one large egg per day or an equivalent amount of egg substitute for 12 weeks. Blood samples were obtained to analyze lipid profile and biomarkers associated with glycemic control at all time points. Regular egg consumption resulted in improvements of fasting blood glucose, which was significantly (P = 0.05) reduced by 4.4% at the final visit in the egg group. Participants in the egg group had significantly (P = 0.01) lower levels of homeostatic model assessment of insulin resistance (HOMA-IR) at all visits. In the egg group, ATP-binding cassette protein family A1 (ABCA1) was significantly higher at the 6-week visit (0.78 ± 0.21 vs. 0.28 ± 0.05 mg dL−1, P < 0.001) and tended to be higher at the final visit (0.62 ± 0.11 vs. 0.55 ± 0.18 mg dL−1, P = 0.1). The mean apolipoprotein A1 (apo A1) level was also significantly higher at the final visit in the egg group compared to the control (147.43 ± 5.34 vs. 142.81 ± 5.09 mg dL−1, P = 0.01). There were no significant changes in total cholesterol and low-density lipoprotein cholesterol (LDL-C) levels. Daily consumption of one large egg may reduce the risk of diabetes without having any adverse effects on lipid profiles in individuals with pre- and type II diabetes.

22 February 2021 in Frontiers in Digital Health
Verified
Journal Article
Open access
BSBenjamin Shickel
Benjamin Shickel
ADAnis Davoudi
Anis Davoudi
TOTezcan Ozrazgat-Baslanti
Tezcan Ozrazgat-Baslanti
MRMatthew Ruppert
Matthew Ruppert
Azra BihoracAzra Bihorac
Azra Bihorac
PRParisa Rashidi
Parisa Rashidi
Accurate prediction and monitoring of patient health in the intensive care unit can inform shared decisions regarding appropriateness of care delivery, risk-reduction strategies, and intensive care resource use. Traditionally, algorithmic solutions for patient outcome prediction rely solely on data available from electronic health records (EHR). In this pilot study, we explore the benefits of augmenting existing EHR data with novel measurements from wrist-worn activity sensors as part of a clinical environment known as the Intelligent ICU. We implemented temporal deep learning models based on two distinct sources of patient data: (1) routinely measured vital signs from electronic health records, and (2) activity data collected from wearable sensors. As a proxy for illness severity, our models predicted whether patients leaving the intensive care unit would be successfully or unsuccessfully discharged from the hospital. We overcome the challenge of small sample size in our prospective cohort by applying deep transfer learning using EHR data from a much larger cohort of traditional ICU patients. Our experiments quantify added utility of non-traditional measurements for predicting patient health, especially when applying a transfer learning procedure to small novel Intelligent ICU cohorts of critically ill patients.