Sahar Safarloo

Mrs. Sahar Safarloo

Universidad Carlos III de Madrid, Leganés, Spain
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SSSahar Safarloo
Sahar Safarloo
ANArántzazu Núñez-Cascajero
Arántzazu Núñez-Cascajero
Ruben Sanchez-GomezRuben Sanchez-Gomez
Ruben Sanchez-Gomez
CVCarmen Vazquez
Carmen Vazquez
The proper measurement of plantar pressure during gait is critical for the clinical diagnosis of foot problems. Force platforms and wearable devices have been developed to study gait patterns during walking or running. However, these devices are often expensive, cumbersome, or have boundary constraints that limit the participant’s motions. Recent advancements in the quality of plastic optical fiber (POF) have made it possible to manufacture a low-cost bend sensor with a novel design for use in plantar pressure monitoring. An intensity-based POF bend sensor is not only lightweight, non-invasive, and easy to construct, but it also produces a signal that requires almost no processing. In this work, we have designed, fabricated, and characterized a novel intensity POF sensor to detect the force applied by the human foot and measure the gait pattern. The sensors were put through a series of dynamic and static tests to determine their measurement range, sensitivity, and linearity, and their response was compared to that of two different commercial force sensors, including piezo resistive sensors and a clinical force platform. The results suggest that this novel POF bend sensor can be used in a wide range of applications, given its low cost and non-invasive nature. Feedback walking monitoring for ulcer prevention or sports performance could be just one of those applications.

27 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SSSahar Safarloo
Sahar Safarloo
AMAlberto Tapetado Moraleda
Alberto Tapetado Moraleda
CVCarmen Vazquez
Carmen Vazquez
Taking non-contact temperature measurements in narrow areas or confined spaces of non-uniform surfaces requires high spatial resolution and independence of emissivity uncertainties that conventional cameras can hardly provide. Two-color optical fiber (OF) pyrometers based on standard single-mode (SMF) and multi-mode optical fibers (MMF) with a small core diameter and low numerical aperture in combination with associated commercially available components can provide a spatial resolution in the micrometer range, independent of the material’s emissivity. Our experiment involved using a patterned microheater to generate temperatures of approximately 340 °C on objects with a diameter of 0.25 mm. We measured these temperatures using two-color optical fiber pyrometers at a 1 kHz sampling rate, which were linearized in the range of 250 to 500 °C. We compared the results with those obtained using an industrial infrared camera. The tests show the potential of our technique for quickly measuring temperature gradients in small areas, independent of emissivity, such as in microthermography. We also report simulations and experiments, showing that the optical power gathered via each channel of the SMF and MMF pyrometers from hot objects of 250 µm is independent of distance until the OF light spot becomes larger than the diameter of the object at 0.9 mm and 0.4 mm, respectively.

20 April 2026 in Applied Materials Today
Verified
Journal Article
Open access
ESE. Cinar San Segundo
E. Cinar San Segundo
LKL.B. Kunkels
L.B. Kunkels
SSSahar Safarloo
Sahar Safarloo
LZL. van Zanten
L. van Zanten
LFL.E. Fratila-Apachitei
L.E. Fratila-Apachitei
MMM.J. Mirzaali
M.J. Mirzaali

17 February 2026 in Optics Express
Verified
Journal Article
Open access
SSSahar Safarloo
Sahar Safarloo
RERamazan Tufan Erdogan
Ramazan Tufan Erdogan
WWWouter J. Westerveld
Wouter J. Westerveld
AZAmir A. Zadpoor
Amir A. Zadpoor
PSPeter G. Steeneken
Peter G. Steeneken
MMMohammad J. Mirzaali
Mohammad J. Mirzaali
Real-time mapping of small forces with micrometer resolution is essential for studying soft and biological matter. However, existing techniques are slow, limited in spatial sampling or require non-planar substrates that can perturb cell behavior. Here we present silicon sensor arrays for rapid surface force mapping that operate using the elasto-optically induced wavelength shift in thin polymer-cladded optical ring resonators. Using a nano-indenter, we demonstrate that the sensor array reaches a force resolution down to 12 μN and shows a linear response. We present both a five-ring linear array and a 10×5 two-dimensional array at 15 μm pitch, and demonstrate the feasibility of localization and force mapping of a spherical nanoindentation tip. Combined measurement of forces by nano-indenter and the optical ring resonator sensor presents a methodology for calibrating this type of photonic force sensor. Moreover, good correspondence between measurements and finite element simulations provides evidence for the proposed operation mechanism. The shown combination of biocompatible claddings, strong opto-mechanical coupling, and foundry-ready photonics, presents a route towards scalable, real-time force mapping for soft-matter metrology, tactile interfaces, and in vitro mechanobiology.