Bane Popadic

Dr. Bane Popadic


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2019 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
Luka StrezoskiLuka Strezoski
Luka Strezoski
BDBoris Dumnic
Boris Dumnic
BPBane Popadic
Bane Popadic
MPMarija Prica
Marija Prica
KLKenneth A. Loparo
Kenneth A. Loparo
In this paper, novel models for electronically coupled distributed energy resources (ECDERs) for online fault calculations of large-scale systems are proposed. ECDERs have different fault responses than traditional synchronous and induction (AC) machines, and generally accepted models for these emerging DERs do not exist. The deployment of ECDERs is constantly increasing worldwide and there is an urgent need for developing appropriate models for fault calculations. In order to have fast calculations, applicable to large-scale systems, the dynamic behavior of traditional AC machines have been approximated in three steady state time-periods (sub-transient, transient, and steady-state). Accordingly, the online fault calculations of large-scale systems have been conducted for these three periods. To simulate the ECDERs' dynamic behavior, and develop models that are compliant with traditional fault calculations, fault models of ECDERs in the sub-transient, transient, and steady-state periods are proposed, with a short peak current period included in the proposed models during the sub-transient period. To validate the proposed models, they are integrated into recently developed online fault calculations, and tested on various large-scale systems. Results from computer simulations are compared with results obtained using state-of-the-art laboratory equipment, as well as with relevant reports on fault current contributions of ECDERs. The results match very well, further validating the proposed models.

27 June 2018 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
BPBane Popadic
Bane Popadic
BDBoris Dumnic
Boris Dumnic
DMDragan Milicevic
Dragan Milicevic
VKVladimir Katic
Vladimir Katic
DSDamir Sljivac
Damir Sljivac

10 January 2024 in Electronics
Verified
Journal Article
Open access
PDF file
VRVladimir Rajs
Vladimir Rajs
DHDejana Herceg
Dejana Herceg
ŽDŽivadin Despotović
Živadin Despotović
MBMiroslav Bogdanović
Miroslav Bogdanović
MŠMirjana Šiljegović
Mirjana Šiljegović
Vladimir TadicVladimir Tadic
Vladimir Tadic
This paper presents a comprehensive analysis of the dead-time effects in wireless power transfer systems based on LCC-S topology. In these systems operating at high frequencies, the ratio of dead-time versus the operating period becomes critical, and the dead-time issue can cause certain problems regarding power quality, efficiency, and output voltage ripple. The impact of input quantities such as voltage and switching frequency on the efficiency and output power of the LCC-S-tuned WPT system was also investigated. The optimal combination of these parameters used to achieve the maximum efficiency for a target output power and to set the appropriate value of the dead time were determined by running multiple simulations using the MATLAB R2023b software platform. It was also shown that the output voltage remained unchanged with and without a load and up to 1200 ns of dead-time, which provides a simple implementation of the corresponding mathematical model. In the recommended interval of 600–1500 ns, the influence of the dead-time on the value of the output voltage amplitude is less than 10%. The validity of the proposed method was confirmed through the implementation of the experimental prototype, a 5 kW wireless power transmission system, and the obtained results were in accordance with the simulation results.

9 April 2019 in Energies
Verified
Journal Article
Open access
PDF file
BDBoris Dumnic
Boris Dumnic
BPBane Popadic
Bane Popadic
DMDragan Mitar Milicevic
Dragan Mitar Milicevic
NVNikola D. Vukajlovic
Nikola D. Vukajlovic
Marko DelimarMarko Delimar
Marko Delimar
The development in distributed energy resources technology has led to a significant amount of non-linear power electronics converters to be integrated in the power system. Although this leads to a more sustainable system, it also can have adverse impacts on system stability and energy power quality. More importantly, the majority of the distribution power systems currently are unbalanced (with asymmetrical voltages) due to load unbalance, while the most common fault types are unbalanced grid faults that can have many adverse effects on distributed resource operations. In that regard, proper control of the grid connected converters in active unbalanced distribution systems will become very important. This paper aims to present the behavior of the advanced grid connected converter control technique under different voltage states at the point of common coupling (according to the ABC classification). The main insufficiencies of the classical control technique will be highlighted, while the paper will propose an appropriate solution for mitigation of negative sequence currents under asymmetrical voltages at the point of common coupling. An extensive experimental verification of the proposed techniques is performed using an advanced laboratory prototype for research in grid integration of distributed resources. The experimental verification clearly demonstrates the benefits offered by the advanced control strategy.

14 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
ZCZoltan Corba
Zoltan Corba
BPBane Popadic
Bane Popadic
DMDragan Mitar Milicevic
Dragan Mitar Milicevic
BDBoris Dumnic
Boris Dumnic
Vladimir KatićVladimir Katić
Vladimir Katić
Partial shading conditions of photovoltaic (PV) modules often occurs in urban areas leading to losses in electricity power generation of the PV power plant. The purpose of this study is to present how the PV power plant with high value of inverter power sizing factor (Kinv) can achieve high performance and power production under partial shading conditions with high shading losses. In this paper the results of long-term monitoring, performance analysis and experimental results are presented, while the results are compared to the estimated values calculated using PVsyst software. The study focused on the PV power plant at the Faculty of Technical Sciences (FTS) in Novi Sad, Republic of Serbia, for the period between the years 2012 and 2019. It has been shown that the values of PV power plant performance parameters are better than expected (very high), and resemble the power plants operating without shading. The high value of the inverter power sizing factor may lead to occasional saturation of the inverter when certain conditions are met, but most of the times it allows the inverter to operate at a more optimal power level. PV module soiling and power degradation is within the limits mentioned in the literature. The increase in Kinv in the partial shading conditions favorably affects the performance, does not degrade the efficiency of the inverter at saturation, reduces the effect of soiling and aging of PV modules, leading to higher power production.

1 January 2023 in Journal on Processing and Energy in Agriculture
Verified
Journal Article
Open access
PDF file
ZCZoltan Corba
Zoltan Corba
DMDragan Mitar Milicevic
Dragan Mitar Milicevic
BDBoris Dumnic
Boris Dumnic
BPBane Popadic
Bane Popadic
The amendment of the Law on Energy and the adoption of the new Law on Renewable Energy Sources enabled a sudden increase in the installed capacity of photovoltaic (PV) power plants in the Republic of Serbia in 2022. Thanks to the new modality called prosumers, interest in the construction of PV power plants has increased, both with households and with commercial entities. The general situation in the world, crises, pandemics and wars have caused a drastic increase in the price of energy products, and therefore electricity. To contribute to the reduction of the negative impact of climate change, it is an ideal opportunity to use the production of electricity from one's own power plant to compensate for an increased cost of energy. The most affordable and simplest is the construction of the PV power plant because solar energy reaches every roof. This paper describes the possibilities of building PV power plants in the status of prosumers from the technical and legal aspects. In addition to examples from practice, the current state of installed capacities of PV power plants in the Republic of Serbia in the status of prosumers is given.