Meha Qassem

Dr. Meha Qassem

Resarch Centre for Biomedical Engineering, School of Mathematics, Computer Science and Engineering, Department of Electrical and Electronic Engineering, City, University of London, Northampton Square, London, EC1V 0HB, UK

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2023 in Physiological Measurement
Verified
Journal Article
Open access
RARaghda Al-Halawani
Raghda Al-Halawani
Peter CharltonPeter Charlton
Peter Charlton
Meha QassemMeha Qassem
Meha Qassem
Panicos KyriacouPanicos Kyriacou
Panicos Kyriacou
Objective . Pulse oximetry is a non-invasive optical technique used to measure arterial oxygen saturation (SpO 2 ) in a variety of clinical settings and scenarios. Despite being one the most significant technological advances in health monitoring over the last few decades, there have been reports on its various limitations. Recently due to the Covid-19 pandemic, questions about pulse oximeter technology and its accuracy when used in people with different skin pigmentation have resurfaced, and are to be addressed. Approach . This review presents an introduction to the technique of pulse oximetry including its basic principle of operation, technology, and limitations, with a more in depth focus on skin pigmentation. Relevant literature relating to the performance and accuracy of pulse oximeters in populations with different skin pigmentation are evaluated. Main Results . The majority of the evidence suggests that the accuracy of pulse oximetry differs in subjects of different skin pigmentations to a level that requires particular attention, with decreased accuracy in patients with dark skin. Significance . Some recommendations, both from the literature and contributions from the authors, suggest how future work could address these inaccuracies to potentially improve clinical outcomes. These include the objective quantification of skin pigmentation to replace currently used qualitative methods, and computational modelling for predicting calibration algorithms based on skin colour.

2 January 2023 in Stress
Verified
Journal Article
Open access
TATashfia Ahmed
Tashfia Ahmed
Meha QassemMeha Qassem
Meha Qassem
Panicos KyriacouPanicos Kyriacou
Panicos Kyriacou
Psychological stress and its inevitable trajectory toward mental health deteriorations such as clinical and major depression has become an unprecedented global burden. The diagnostic procedures involved in the characterization of mental illnesses commonly follow qualitative and subjective measures of stress, often leading to greater socioeconomic burdens due to misdiagnosis and poor understanding of the severity of such illnesses, further fueled by the stigmatization surrounding mental health. In recent years, the application of cortisol and stress hormone measurements has given rise to an alternative, quantifiable approach for the psychological evaluation of stress and depression. This review comprehensively evaluates the current state-of-the-art technology for measuring cortisol and dehydroepiandrosterone (DHEA) and their applications within stress monitoring in humans. Recent advancements in these fields have shown the importance of measuring stress hormones for the characterization of stress manifestation within the human body, and its relevance in mental health decline. Preliminary results from studies considering multimodal approaches toward stress monitoring have showcased promising developments, emphasizing the need for further technological advancement in this field, which consider both neurochemical and physiological biomarkers of stress, for global benefit.

21 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
IGIman Maimunat Gidado
Iman Maimunat Gidado
Meha QassemMeha Qassem
Meha Qassem
ITIasonas F. Triantis
Iasonas F. Triantis
Panicos KyriacouPanicos Kyriacou
Panicos Kyriacou
The presence of water in the skin is crucial for maintaining the properties and functions of the skin, in particular its outermost layer, known as the stratum corneum, which consists of a lipid barrier. External exposures can affect the skin’s hydration levels and in turn, alter its mechanical and physical properties. Monitoring these alterations in the skin’s water content can be applicable in clinical, cosmetic, athletic and personal settings. Many techniques measuring this parameter have been investigated, with electrical-based methods currently being widely used in commercial devices. Furthermore, the exploration of optical techniques to measure hydration is growing due to the outcomes observed through the penetration of light at differing levels. This paper comprehensively reviews such measurement techniques, focusing on recent experimental studies and state-of-the-art devices.

9 March 2019 in Cosmetics
Verified
Journal Article
Open access
PDF file
Meha QassemMeha Qassem
Meha Qassem
Panicos KyriacouPanicos Kyriacou
Panicos Kyriacou
Skin hydration is a complex process that influences the physical and mechanical properties of skin. Various technologies have emerged over the years to assess this parameter, with the current standard being electrical probe-based instruments. Nevertheless, their inability to provide detailed information has prompted the use of sophisticated spectroscopic and imaging methodologies, which are capable of in-depth skin analysis that includes structural and composition details. Modern imaging and spectroscopic techniques have transformed skin research in the dermatological and cosmetics disciplines, and are now commonly employed in conjunction with traditional methods for comprehensive assessment of both healthy and pathological skin. This article reviews current techniques employed in measuring skin hydration, and gives an account on their principle of operation and applications in skin-related research.

9 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SPSzymon Paprocki
Szymon Paprocki
Meha QassemMeha Qassem
Meha Qassem
Panicos KyriacouPanicos Kyriacou
Panicos Kyriacou
The field of alcohol intoxication sensing is over 100 years old, spanning the fields of medicine, chemistry, and computer science, aiming to produce the most effective and accurate methods of quantifying intoxication levels. This review presents the development and the current state of alcohol intoxication quantifying devices and techniques, separated into six major categories: estimates, breath alcohol devices, bodily fluid testing, transdermal sensors, mathematical algorithms, and optical techniques. Each of these categories was researched by analyzing their respective performances and drawbacks. We found that the major developments in monitoring ethanol intoxication levels aim at noninvasive transdermal/optical methods for personal monitoring. Many of the “categories” of ethanol intoxication systems overlap with each other with to a varying extent, hence the division of categories is based only on the principal operation of the techniques described in this review. In summary, the gold-standard method for measuring blood ethanol levels is through gas chromatography. Early estimation methods based on mathematical equations are largely popular in forensic fields. Breath alcohol devices are the most common type of alcohol sensors on the market and are generally implemented in law enforcement. Transdermal sensors vary largely in their sensing methodologies, but they mostly follow the principle of electrical sensing or enzymatic reaction rate. Optical devices and methodologies perform well, with some cases outperforming breath alcohol devices in terms of the precision of measurement. Other estimation algorithms consider multimodal approaches and should not be considered alcohol sensing devices, but rather as prospective measurement of the intoxication influence. This review found 38 unique technologies and techniques for measuring alcohol intoxication, which is testament to the acute interest in the innovation of noninvasive technologies for assessing intoxication.

19 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MSMahsa Sheikh
Mahsa Sheikh
Meha QassemMeha Qassem
Meha Qassem
ITIasonas F. Triantis
Iasonas F. Triantis
Panicos KyriacouPanicos Kyriacou
Panicos Kyriacou
Since the mid-20th century, lithium continues to be prescribed as a first-line mood stabilizer for the management of bipolar disorder (BD). However, lithium has a very narrow therapeutic index, and it is crucial to carefully monitor lithium plasma levels as concentrations greater than 1.2 mmol/L are potentially toxic and can be fatal. The quantification of lithium in clinical laboratories is performed by atomic absorption spectrometry, flame emission photometry, or conventional ion-selective electrodes. All these techniques are cumbersome and require frequent blood tests with consequent discomfort which results in patients evading treatment. Furthermore, the current techniques for lithium monitoring require highly qualified personnel and expensive equipment; hence, it is crucial to develop low-cost and easy-to-use devices for decentralized monitoring of lithium. The current paper seeks to review the pertinent literature rigorously and critically with a focus on different lithium-monitoring techniques which could lead towards the development of automatic and point-of-care analytical devices for lithium determination.