Matthias Port

Prof. Matthias Port

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2019 in Cancers
Verified
Journal Article
Open access
PDF file
HSHarry Scherthan
Harry Scherthan
JLJin-Ho Lee
Jin-Ho Lee
EMEmanuel Maus
Emanuel Maus
SSSarah Schumann
Sarah Schumann
RMRazan Muhtadi
Razan Muhtadi
Michael HausmannMichael Hausmann
Michael Hausmann
Background: Cancer patients are increasingly treated with alpha-particle-emitting radiopharmaceuticals. At the subcellular level, alpha particles induce densely spaced ionizations and molecular damage. Induction of DNA lesions, especially clustered DNA double-strand breaks (DSBs), threatens a cell’s survival. Currently, it is under debate to what extent the spatial topology of the damaged chromatin regions and the repair protein arrangements are contributing. Methods: Super-resolution light microscopy (SMLM) in combination with cluster analysis of single molecule signal-point density regions of DSB repair markers was applied to investigate the nano-structure of DNA damage foci tracks of Ra-223 in-solution irradiated leukocytes. Results: Alpha-damaged chromatin tracks were efficiently outlined by γ-H2AX that formed large (super) foci composed of numerous 60–80 nm-sized nano-foci. Alpha damage tracks contained 60–70% of all γ-H2AX point signals in a nucleus, while less than 30% of 53BP1, MRE11 or p-ATM signals were located inside γ-H2AX damage tracks. MRE11 and p-ATM protein fluorescent tags formed focal nano-clusters of about 20 nm peak size. There were, on average, 12 (±9) MRE11 nanoclusters in a typical γ-H2AX-marked alpha track, suggesting a minimal number of MRE11-processed DSBs per track. Our SMLM data suggest regularly arranged nano-structures during DNA repair in the damaged chromatin domain.

21 June 2022 in Tomography
Verified
Journal Article
Open access
PDF file
SWStephan Waldeck
Stephan Waldeck
DODaniel Overhoff
Daniel Overhoff
Leona S. AlizadehLeona S. Alizadeh
Leona S. Alizadeh
BBBenjamin Becker
Benjamin Becker
MPMatthias Port
Matthias Port
SSSandra Schmidt
Sandra Schmidt
Cochlear implants (CIs) are the primary treatment method in patients with profound sensorineural hearing loss. Interpretation of postoperative imaging with conventional energy-integrating detector computed tomography (EID-CT) following CI surgery remains challenging due to metal artifacts. Still, the photon-counting detector (PCD-CT) is a new emerging technology with the potential to eliminate these problems. This study evaluated the performance of virtual monoenergetic (VME) EID-CT images versus PCD-CT in CI imaging. In this cadaveric study, two temporal bone specimens with implanted CIs were scanned with EID-CT and PCD-CT. The images were assessed according to the visibility of interelectrode wire, size of electrode contact, and diameter of halo artifacts. The visibility of interelectrode wire sections was significantly higher when reviewing PCD-CT images. The difference in diameter measurements for electrode contacts between the two CT scanner modalities showed that the PCD-CT technology generally led to significantly larger diameter readings. The larger measurements were closer to the manufacturer’s specifications for the CI electrode. The size of halo artifacts surrounding the electrode contacts did not differ significantly between the two imaging modalities. PCT-CT imaging is a promising technology for CI imaging with improved spatial resolution and better visibility of small structures than conventional EID-CT.

1 August 2017 in Radiation Research
Verified
Journal Article
Closed access
MPMatthias Port
Matthias Port
BPB. Pieper
B. Pieper
TKT. Knie
T. Knie
HDH. Dörr
H. Dörr
AGA. Ganser
A. Ganser
MAM. Abend
M. Abend
Rapid clinical triage of radiation injury patients is essential for determining appropriate diagnostic and therapeutic interventions. We examined the utility of blood cell counts (BCCs) in the first three days postirradiation to predict clinical outcome, specifically for hematologic acute radiation syndrome (HARS). We analyzed BCC test samples from radiation accident victims (n = 135) along with their clinical outcome HARS severity scores (H1–4) using the System for Evaluation and Archiving of Radiation Accidents based on Case Histories (SEARCH) database. Data from nonirradiated individuals (H0, n = 132) were collected from an outpatient facility. We created binary categories for severity scores, i.e., 1 (H0 vs. H1–4), 2 (H0–1 vs. H2–4) and 3 (H0–2 vs. H3–4), to assess the discrimination ability of BCCs using unconditional logistic regression analysis. The test sample contained 454 BCCs from 267 individuals. We validated the discrimination ability on a second independent group comprised of 275 BCCs from 2...

8 June 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
HKHanns Leonhard Kaatsch
Hanns Leonhard Kaatsch
BBBenjamin Becker
Benjamin Becker
SSSimone Schüle
Simone Schüle
POPatrick Ostheim
Patrick Ostheim
KNKai Nestler
Kai Nestler
RUReinhard Ullmann
Reinhard Ullmann
Dual-energy CT provides enhanced diagnostic power with similar or even reduced radiation dose as compared to single-energy CT. Its principle is based on the distinct physical properties of low and high energetic photons, which, however, may also affect the biological effectiveness and hence the extent of CT-induced cellular damage. Therefore, a comparative analysis of biological effectiveness of dual- and single-energy CT scans with focus on early gene regulation and frequency of radiation-induced DNA double strand breaks (DSBs) was performed. Blood samples from three healthy individuals were irradiated ex vivo with single-energy (80 kV and 150 kV) and dual-energy tube voltages (80 kV/Sn150kV) employing a modern dual source CT scanner resulting in Volume Computed Tomography Dose Index (CTDIvol) of 15.79–18.26 mGy and dose length product (DLP) of 606.7–613.8 mGy*cm. Non-irradiated samples served as a control. Differential gene expression in peripheral blood mononuclear cells was analyzed 6 h after irradiation using whole transcriptome sequencing. DSB frequency was studied by 53BP1 + γH2AX co-immunostaining and microscopic evaluation of their focal accumulation at DSBs. Neither the analysis of gene expression nor DSB frequency provided any evidence for significantly increased biological effectiveness of dual-energy CT in comparison to samples irradiated with particular single-energy CT spectra. Relative to control, irradiated samples were characterized by a significantly higher rate of DSBs (p < 0.001) and the shared upregulation of five genes, AEN, BAX, DDB2, FDXR and EDA2R, which have already been suggested as radiation-induced biomarkers in previous studies. Despite steadily decreasing doses, CT diagnostics remain a genotoxic stressor with impact on gene regulation and DNA integrity. However, no evidence was found that varying X-ray spectra of CT impact the extent of cellular damage.

Verified
Journal Article
Open access
PDF file
MPMatthias Port
Matthias Port
FHFrancis Hérodin
Francis Hérodin
MVMarco Valente
Marco Valente
MDMichel Drouet
Michel Drouet
RUReinhard Ullmann
Reinhard Ullmann
MAMichael Abend
Michael Abend
Radiosensitivity differs in humans and likely among primates. The reasons are not well known. We examined pre-exposure gene expression in baboons (n = 17) who developed haematologic acute radiation syndrome (HARS) without pancytopenia or a more aggravated HARS with pancytopenia after irradiation. We evaluated gene expression in a two stage study design where stage I comprised a whole genome screen for messenger RNAs (mRNA) (microarray) and detection of 667 microRNAs (miRNA) (real-time quantitative polymerase chain reaction (qRT-PCR) platform). Twenty candidate mRNAs and nine miRNAs were selected for validation in stage II (qRT-PCR). None of the mRNA species could be confirmed during the validation step, but six of the nine selected candidate miRNA remained significantly different during validation. In particular, miR-425-5p (receiver operating characteristic = 0.98; p = 0.0003) showed nearly complete discrimination between HARS groups with and without pancytopenia. Target gene searches of miR-425-5p identified new potential mRNAs and associated biological processes linked with radiosensitivity. We found that one miRNA species examined in pre-exposure blood samples was associated with HARS characterized by pancytopenia and identified new target mRNAs that might reflect differences in radiosensitivity of irradiated normal tissue.

17 March 2022 in Cancers
Verified
Journal Article
Open access
PDF file
HSHarry Scherthan
Harry Scherthan
SWStephanie-Quinta Wagner
Stephanie-Quinta Wagner
JGJan Grundhöfer
Jan Grundhöfer
NMNicole Matejka
Nicole Matejka
JMJessica Müller
Jessica Müller
Judith ReindlJudith Reindl
Judith Reindl
Purpose: High doses of ionizing radiation in radiotherapy can elicit undesirable side effects to the skin. Proton minibeam radiotherapy (pMBRT) may circumvent such limitations due to tissue-sparing effects observed at the macro scale. Here, we mapped DNA damage dynamics in a 3D tissue context at the sub-cellular level. Methods: Epidermis models were irradiated with planar proton minibeams of 66 µm, 408 µm and 920 µm widths and inter-beam-distances of 2.5 mm at an average dose of 2 Gy using the scanning-ion-microscope SNAKE in Garching, GER. γ-H2AX + 53BP1 and cleaved-caspase-3 immunostaining revealed dsDNA damage and cell death, respectively, in time courses from 0.5 to 72 h after irradiation. Results: Focused 66 µm pMBRT induced sharply localized severe DNA damage (pan-γ-H2AX) in cells at the dose peaks, while damage in the dose valleys was similar to sham control. pMBRT with 408 µm and 920 µm minibeams induced DSB foci in all cells. At 72 h after irradiation, DNA damage had reached sham levels, indicating successful DNA repair. Increased frequencies of active-caspase-3 and pan-γ-H2AX-positive cells revealed incipient cell death at late time points. Conclusions: The spatially confined distribution of DNA damage appears to underlie the tissue-sparing effect after focused pMBRT. Thus, pMBRT may be the method of choice in radiotherapy to reduce side effects to the skin.