Andrius Petrėnas

Andrius Petrėnas


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
APAndrius Petrėnas
Andrius Petrėnas
VMVaidotas Marozas
Vaidotas Marozas
LSLeif Sörnmo
Leif Sörnmo

14 December 2014 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
APAndrius Petrėnas
Andrius Petrėnas
LSLeif Sörnmo
Leif Sörnmo
ALArūnas Lukoševičius
Arūnas Lukoševičius
VMVaidotas Marozas
Vaidotas Marozas

28 February 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MHMikael Henriksson
Mikael Henriksson
APAndrius Petrėnas
Andrius Petrėnas
VMVaidotas Marozas
Vaidotas Marozas
FSFrida Samdberg
Frida Samdberg
LSLeif Sörnmo
Leif Sörnmo
Objective: The detection and analysis of atrial fibrillation (AF) in the ECG is greatly influenced by signal quality. The present study proposes and evaluates a model-based f-wave signal quality index (SQI), denoted S, for use in the QRST-cancelled ECG signal. Methods:S is computed using a harmonic f-wave model, allowing for variation in frequency and amplitude. The properties of S are evaluated on both f-waves and P-waves using 378 12-lead ECGs, 1875 single-lead ECGs, and simulated signals. Results: S decreases monotonically when noise is added to f-wave signals, even for noise which overlaps spectrally with f-waves. Moreover, S is shown to be closely associated with the accuracy of AF frequency estimation, where S > 0.3 implies accurate estimation. When S is used as a measure of fwave presence, AF detection performance improves: the sensitivity increases from 97.0% to 98.1% and the specificity increases from 97.4% to 97.8% when compared to the reference detector. Conclusion: The proposed SQI represents a novel approach to assessing f-wave signal quality, as well as to determining whether f-waves are present. Significance: The use of S improves the detection of AF and benefits the analysis of noisy ECGs.

22 March 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
MBMonika Butkuviene
Monika Butkuviene
APAndrius Petrėnas
Andrius Petrėnas
ASAndrius Solosenko
Andrius Solosenko
AYAlba Martin Yebra
Alba Martin Yebra
VMVaidotas Marozas
Vaidotas Marozas
LSLeif Sörnmo
Leif Sörnmo
Objective: A large number of atrial fibrillation (AF) detectors have been published in recent years, signifying that the comparison of detector performance plays a central role, though not always consistent. The aim of this study is to shed needed light on aspects crucial to the evaluation of detection performance. Methods: Three types of AF detector, using either information on rhythm, rhythm and morphology, or segments of ECG samples, are implemented and studied on both real and simulated ECG signals. The properties of different performance measures are investigated, for example, in relation to dataset imbalance. Results: The results show that performance can differ considerably depending on the way detector output is compared to database annotations, i.e., beat-to-beat, segment-to-segment, or episode-to-episode comparison. Moreover, depending on the type of detector, the results substantiate that physiological and technical factors, e.g., changes in ECG morphology, rate of atrial premature beats, and noise level, can have a considerable influence on performance. Conclusion: The present study demonstrates overall strengths and weaknesses of different types of detector, highlights challenges in AF detection, and proposes five recommendations on how to handle data and characterize performance.

1 March 2015 in Journal of Electrocardiology
Verified
Journal Article
Closed access
APAndrius Petrėnas
Andrius Petrėnas
VMVaidotas Marozas
Vaidotas Marozas
GJG. Jaruševičius
G. Jaruševičius
LSL. Sörnmo
L. Sörnmo

1 November 2017 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
APAndrius Petrėnas
Andrius Petrėnas
VMVaidotas Marozas
Vaidotas Marozas
ASAndrius Sološenko
Andrius Sološenko
RKRaimondas Kubilius
Raimondas Kubilius
JSJurgita Skibarkiene
Jurgita Skibarkiene
LSLeif Sörnmo
Leif Sörnmo
Objective : A model for simulating multi-lead ECG signals during paroxysmal atrial fibrillation (AF) is proposed. Significance : The model is of particular significance when evaluating detection performance in the presence of brief AF episodes, especially since annotated databases with such episodes are lacking. Approach : The proposed model accounts for important characteristics such as switching between sinus rhythm and AF, varying P-wave morphology, repetition rate of f-waves, presence of atrial premature beats, and various types of noise. Main results : Two expert cardiologists assessed the realism of simulated signals relative to real ECG signals, both in sinus rhythm and AF. The cardiologists identified the correct rhythm in all cases, and considered two-thirds of the simulated signals as realistic. The proposed model was also investigated by evaluating the performance of two AF detectors which explored either rhythm only or both rhythm and morphology. The results show that detection performance is strongly dependent on AF episode duration, and, consequently, demonstrate that the model can play a significant role in the investigation of detector properties.