Objective: The present study addresses the problem of estimating the respiratory rate from the morphological ECG variations in the presence of atrial fibrillatory waves (f-waves). The significance of performing f-wave suppression before respiratory rate estimation is investigated. Methods: The performance of a novel approach to ECG-derived respiration, named “slope range” (SR) and designed particularly for operation in atrial fibrillation (AF), is compared to that of two well-known methods based on either R-wave angle (RA) or QRS loop rotation angle (LA). A novel rule is proposed for spectral peak selection in respiratory rate estimation. The suppression of f-waves is accomplished using signal- and noise-dependent QRS weighted averaging. The performance evaluation embraces real as well as simulated ECG signals acquired from patients with persistent AF; the estimation error of the respiratory rate is determined for both types of signals. Results: Using real ECG signals and reference respiratory signals, rate estimation without f-wave suppression resulted in a median error of 0.015 ± 0.021 Hz and 0.019 ± 0.025 Hz for SR and RA, respectively, whereas LA with f-wave suppression resulted in 0.034 ± 0.039 Hz. Using simulated signals, the results also demonstrate that f-wave suppression is superfluous for SR and RA, whereas it is essential for LA. Conclusion: The results show that SR offers the best performance as well as computational simplicity since f-wave suppression is not needed. Significance: The respiratory rate can be robustly estimated from the ECG in the presence of AF.
14 December 2014 in Medical & Biological Engineering & Computing
Deep learning models for detecting episodes of atrial fibrillation (AF) using rhythm information in long-term ambulatory ECG recordings have shown high performance. However, the rhythm-based approach does not take advantage of the morphological information conveyed by the different ECG waveforms, particularly the f-waves. As a result, the performance of such models may be inherently limited. To address this limitation, we have developed a deep learning model, named RawECGNet, to detect episodes of AF and atrial flutter (AFl) using the raw, single-lead ECG. We compare the generalization performance of RawECGNet on two external data sets that account for distribution shifts in geography, ethnicity, and lead position. RawECGNet is further benchmarked against a state-of-the-art deep learning model, named ArNet2, which utilizes rhythm information as input. Using RawECGNet, the results for the different leads in the external test sets in terms of the F1 score were 0.91-0.94 in RBDB and 0.93 in SHDB, compared to 0.89-0.91 in RBDB and 0.91 in SHDB for ArNet2. The results highlight RawECGNet as a high-performance, generalizable algorithm for detection of AF and AFl episodes, exploiting information on both rhythm and morphology.
28 February 2018 in IEEE Transactions on Biomedical Engineering
Objective: The detection and analysis of atrial fibrillation (AF) in the ECG is greatly influenced by signal quality. The present study proposes and evaluates a model-based f-wave signal quality index (SQI), denoted S, for use in the QRST-cancelled ECG signal. Methods:S is computed using a harmonic f-wave model, allowing for variation in frequency and amplitude. The properties of S are evaluated on both f-waves and P-waves using 378 12-lead ECGs, 1875 single-lead ECGs, and simulated signals. Results: S decreases monotonically when noise is added to f-wave signals, even for noise which overlaps spectrally with f-waves. Moreover, S is shown to be closely associated with the accuracy of AF frequency estimation, where S > 0.3 implies accurate estimation. When S is used as a measure of fwave presence, AF detection performance improves: the sensitivity increases from 97.0% to 98.1% and the specificity increases from 97.4% to 97.8% when compared to the reference detector. Conclusion: The proposed SQI represents a novel approach to assessing f-wave signal quality, as well as to determining whether f-waves are present. Significance: The use of S improves the detection of AF and benefits the analysis of noisy ECGs.
22 March 2021 in IEEE Transactions on Biomedical Engineering
Objective: A large number of atrial fibrillation (AF) detectors have been published in recent years, signifying that the comparison of detector performance plays a central role, though not always consistent. The aim of this study is to shed needed light on aspects crucial to the evaluation of detection performance. Methods: Three types of AF detector, using either information on rhythm, rhythm and morphology, or segments of ECG samples, are implemented and studied on both real and simulated ECG signals. The properties of different performance measures are investigated, for example, in relation to dataset imbalance. Results: The results show that performance can differ considerably depending on the way detector output is compared to database annotations, i.e., beat-to-beat, segment-to-segment, or episode-to-episode comparison. Moreover, depending on the type of detector, the results substantiate that physiological and technical factors, e.g., changes in ECG morphology, rate of atrial premature beats, and noise level, can have a considerable influence on performance. Conclusion: The present study demonstrates overall strengths and weaknesses of different types of detector, highlights challenges in AF detection, and proposes five recommendations on how to handle data and characterize performance.
24 December 2014 in IEEE Transactions on Biomedical Engineering
Although patients undergoing hemodialysis treatment often suffer from cardiovascular disease, monitoring of cardiac rhythm is not performed on a routine basis. Without requiring any extra sensor, this study proposes a method for extracting a cardiac signal from the built-in extracorporeal venous pressure sensor of the hemodialysis machine. The extraction is challenged by the fact that the cardiac component is much weaker than the pressure component caused by the peristaltic blood pump. To further complicate the extraction problem, the cardiac component is difficult to separate when the pump and heart rates coincide. The proposed method estimates a cardiac signal by subtracting an iteratively refined blood pump model signal from the signal measured at the extracorporeal venous pressure sensor. The method was developed based on simulated pressure signals, and evaluated on clinical pressure signals acquired during hemodialysis treatment. The heart rate estimated from the clinical pressure signal was compared to that derived from a photoplethysmographic reference signal, resulting in a difference of 0.07 ± 0.84 beats/min. The accuracy of the heartbeat occurrence times was studied for different strengths of the cardiac component, using both clinical and simulated signals. The results suggest that the accuracy is sufficient for analysis of heart rate and certain arrhythmias.